91.120.99 有关建筑物防护的其他标准 标准查询与下载



共找到 78 条与 有关建筑物防护的其他标准 相关的标准,共 6

Technical specifications for corrosion monitoring and testing of reinforced concrete

ICS
91.120.99
CCS
J 04
发布
2024-03-15
实施
2024-10-01

1.1  This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in (multi- and single-family) residential building construction, not otherwise restricted from use. The scope is limited to instructions relative to the use and installation of RBS, including a surface(s) normally having an emittance of 0.1 or less, such as metallic foil or metallic foil deposits, mounted on substrates. Some examples that this practice is intended to address include: (1) low-emittance surfaces in vented building envelope cavities intended to retard radiant transfer across the airspace: (2) low-emittance surfaces at interior building surfaces intended to retard radiant transfer to, or from, building inhabitants; and (3) low-emittance surface at interior building surfaces intended to reduce radiant transfer to, or from, radiant heating or cooling systems. 1.2  This practice covers the installation process from pre-installation inspection through the post-installation procedure. It does not cover the production of the radiant barrier materials. (See Specification C1313 .) 1.3  This practice is not intended to replace the manufacturer’s installation instructions but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, federal, or international codes. 1.4  This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for installation of radiant barrier materials. It also assumes that the installer understands the fundamentals of residential building construction that affect the installation of RBS. 1.5  The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 5 and 7 . 1.7  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction

ICS
91.120.99
CCS
发布
2024-03-29
实施

1.1  This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in commercial/industrial building construction not otherwise restricted from use. The scope is limited to instruction relative to the use and installation of RBS, including a surface(s) normally having an emittance of 0.1 or less, such as metallic foil or metallic foil deposits, mounted on substrates. Some examples that this practice is intended to address include: (1) low-emittance surfaces in vented building envelope cavities intended to retard radiant transfer across the airspace: (2) low-emittance surfaces at interior building surfaces intended to retard radiant transfer to, or from, building inhabitants; and (3) low-emittance surface at interior building surfaces intended to reduce radiant transfer to, or from, radiant heating or cooling systems. 1.2  This practice covers the installation process from pre-installation inspection through the post-installation procedure. It does not cover the production of the radiant barrier materials. (See Specification C1313 .) 1.3  This practice is not intended to replace the manufacturer’s installation instructions but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, federal, or international codes. 1.4  This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for installation of radiant barrier materials. It also assumes that the installer understands the fundamentals of commercial/industrial building construction that affect the installation of RBS. 1.5  The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 5 and 7 . 1.7  When the installation or use of radiant barrier materials, accessories, and systems has the potential to pose safety or health problems, the manufacturer shall provide the user appropriate current information regarding any known problems associated with the use of the product of the company and shall also specify protective measures. 1.8  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Commercial/Industrial Building Construction

ICS
91.120.99
CCS
发布
2024-03-29
实施

本文件规定了矿物颗粒进行紫外线阻隔性能检测的试验方法和试验报告。

Mineral particles - Technical specifications for ultraviolet blocking performance testing

ICS
91.120.99
CCS
M745
发布
2023-12-15
实施
2023-12-15

Urban rail transit track vibration reduction design and evaluation standards

ICS
91.120.99
CCS
P 31
发布
2023-10-07
实施
2024-04-07

Technical Guidelines for Rural House Structural Safety Hazard Investigation

ICS
91.120.99
CCS
P 16
发布
2023-10-07
实施
2024-04-07

主要技术内容包括:1.总则;2.术语;3.基本规定;4.施工准备;5.施工安装;6.质量验收;7.施工安全与环境保护。

Installation Technical Standard for Precast Concrete External Wall Panels

ICS
91.120.99
CCS
E4710
发布
2023-05-04
实施
2023-06-15

本文件规定了光伏建筑一体化系统工程设计的基本规定、光伏建筑一体化设计、系统设计。 本文件适用于光伏建筑一体化工程设计范围。

Technical specification for building integrated photovoltaic engineering design

ICS
91.120.99
CCS
E4790
发布
2023-04-20
实施
2023-05-01

1.1 This standard practice covers procedures and documentation to assist in the specification and evaluation of preconstruction laboratory mockups of exterior wall systems. 1.2 This standard practice addresses design and construction of the mockup, observation during mockup construction and testing, evaluation of the mockup test results, and documentation of the mockup and testing process. Coordination is required between the parties involved in the design, construction, and testing of the mockup to facilitate this process. Documentation should convey the results of preconstruction mockups from one party to others at appropriate stages in the process. 1.3 This standard practice recommends the selection and order of individual tests performed on the mockup in the absence of a specific test order. 1.4 This standard practice recommends a protocol for exchange of information between participants in the preconstruction mockup process. 1.5 Responsibility for specific activities is recommended by this practice. This practice is intended to provide a default structure in the absence of the assignment of specific responsibilities by the specifying authority. 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Specification and Evaluation of Pre-Construction Laboratory Mockups of Exterior Wall Systems

ICS
91.120.99
CCS
发布
2023-04-15
实施

1.1 These practices cover standardized techniques for locating air leakage sites in building envelopes and air barrier systems. 1.2 Individual practices provide advantages for specific applications. 1.3 Some of the practices require a knowledge of infrared scanning, building and test chamber pressurization and depressurization, smoke and fog generation techniques, sound generation and detection, and tracer gas concentration measurement techniques. 1.4 The practices described are of a qualitative nature in determining the air leakage sites rather than determining quantitative leakage rates. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 6. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems

ICS
91.120.99
CCS
发布
2022-10-01
实施

1.1 The purpose of this specification is to provide general requirements for products used to reduce solar gains on buildings by reflecting solar radiation from roofs and walls. Radiation Control Coating (RCC) is a liquid applied material that cures to form a solid coating having a solar reflectance of at least 0.8 and an ambient temperature infrared emittance of at least 0.8. 1.2 This specification covers the physical and mechanical properties of liquid-applied RCCs designed for exterior application for buildings. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems has the potential to result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Exterior Solar Radiation Control Coatings on Buildings

ICS
91.120.99
CCS
发布
2022-10-01
实施

Emergency shelter identification standards

ICS
91.120.99
CCS
P15
发布
2022-08-27
实施
2022-09-15

适用于新建、改建、扩建住宅小区安全防范系统的设计、施工、评审、检验、验收和维护。单幢、多幢住宅楼、公寓楼、商住楼、别墅等非自建类住宅的安全防范系统可按照国家标准参照本文件执行。

Technical specification for security system of residential area

ICS
91.120.99
CCS
A 91
发布
2022-07-10
实施
2022-08-01

1 Scope 1.1 General This Standard contains best practice guidance for the design and construction of low-rise, wood-frame buildings to withstand high winds corresponding to EF-2 tornado-level wind speeds, assumed to be associated with a reference velocity pressure of 1 kPa. The guidance in this Standard is based on, and written to, supplement the requirements specified in Part 9 of the National Building Code of Canada (NBC) (see Clause 0.4). 1.2 Applicability and limitations The guidance in this Standard has been developed primarily for new wood-frame building construction. The resistance to high wind speeds up to an EF-2 level requires adherence to all provisions and recommendations in this Standard. 1.3 Alterations and additions This Standard can be applied to major alterations and additions to existing buildings where the entire continuous vertical and lateral load path can be upgraded with all primary structural requirements. For alterations and additions to existing buildings where the entire continuous vertical and lateral load path cannot be upgraded, users should start with the non-structural measures provided in Clauses 11through 14. For more information, see Clause 0.3. 1.4 Conflicting requirements In cases where a requirement or method in another standard that is referenced in a regulation conflicts with recommendations in this Standard, the regulatory requirements take precedence. For more information, see Clause 0.5. 1.5 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Design and construction of low-rise residential and small buildings to resist high wind

ICS
91.120.99
CCS
发布
2022-06-01
实施

Early Civil Air Defense Engineering Classification Appraisal Regulations

ICS
91.120.99
CCS
P18
发布
2022-01-07
实施
2022-02-10

1   Scope This British Standard specifies requirements for the designation, testing, factory production control , installation manual, deployment instructions, user manual and marking for different types and configurations of flood resistance products . This British Standard is applicable to flood resistance products intended for use in the temporary sealing of building apertures and entrances to properties, including boards, skirt and wall sealant systems , and flood doors, in the event of static flood water rising above a minimum level of 540 mm above aperture threshold level, except where they are designed to completely cover or replace small apertures, such as airbricks or air vents. The flood resistance products are expected to be effective at flood heights from ground level to the designated maximum water depth (DMWD). It covers wall aperture closure systems and foam products. Skirt and wall sealant systems are used in the temporary sealing of the above or below ground external faces of buildings and properties. This British Standard specifies the method of testing and product performance. The range of building aperture sizes covered is a nominal width of up to 6 000 mm. For skirt and sealant systems the range of building sizes covered is governed by the system constraints, but theoretically the system could be installed to provide protection to any size of building. NOTE 1 The hydrostatic pressures exerted by floodwater can cause sudden or long-t...

Flood resistance products - Building products. Specification

ICS
91.120.99
CCS
发布
2021-11-30
实施
2021-11-30

1   Scope This British Standard specifies requirements for the designation, testing, factory production control , installation manual, deployment instructions, user manual and marking for different types and configurations of flood resistance products . This British Standard is applicable to flood resistance products intended for either temporary installation or to be demountable, for use away from buildings but where they could be sealed against structures or buildings at section ends, in the UK or locations with similar exposures, i.e. where there is a temperate climate. This British Standard specifies the method of testing and an allowable leakage rate. NOTE 1 The test conditions given in Annex A represent typical conditions that can be experienced during a flood. This includes testing the flood resistance product on a concrete base for leakage and structural failure under static water levels, random waves up to 0.1 m high and parallel currents up to 1.0 m/s. NOTE 2 This British Standard does not cover testing with contaminated or saline water; however, product manufacturers are required to provide information about the performance of their products in these conditions (see Annex B). NOTE 3 Flood resistance products that conform to this British Standard might not be suitable for all ...

Flood resistance products - Perimeter barrier systems. Specification

ICS
91.120.99
CCS
发布
2021-11-30
实施
2021-11-30

前  言  1 范围  2 规范性引用文件  3 术语和定义  4 管理职责      4.1 一般规定      4.2 相关方安全管理职责      4.3 施工单位安全管理职责  5 策划      5.1 一般规定      5.2 安全管理目标      5.3 风险控制      5.4 组织体系      5.5 资源配置  6 实施      6.1 一般规定      6.2 目标分解      6.3 履职考核      6.4 风险管控      6.5 资源管控  7 审核      7.1 一般规定      7.2 内部审核      7.3 外部审核  8 改进  9 信息管理  10 资料与记录      10.1 一般规定      10.2 安全管理体系运行资料和记录      10.3 策划的资料和记录      10.4 实施过程的资料和记录      10.5 审核和改进的资料和记录 

Construction site safety production management regulations

ICS
91.120.99
CCS
E4710
发布
2021-11-19
实施
2021-12-30

主要技术内容包括:总则、术语和符号、基本规定、抗连续倒塌、抗地震倒塌、抗火灾倒塌、抗爆炸倒塌、建造阶段及加固改造过程抗倒塌等。

Collapse-resistant design standards for building structures

ICS
91.120.99
CCS
E4710
发布
2021-10-15
实施
2021-10-28

1.1 This practice describes methods for reducing radon entry into existing attached and detached residential buildings three stories or less in height. This practice is intended for use by trained, certified or licensed, or both, or otherwise qualified individuals. 1.2 These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed information is contained in references cited throughout this practice. 1.3 This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems. 1.4 The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s) or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy, and for up to one year after occupancy, are covered by Practice E1465. 1.5 This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions, to fulfill objectives of their specific radon contractor certification or licensure programs. Radon mitigation performed in accordance with this practice is considered ordinary repair. 1.6 The methods addressed in this practice include the following categories of contractor activity: general practices, building investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation. 1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety hazards. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings

ICS
91.120.99
CCS
发布
2021-10-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号