97.100.20 气体加热器 标准查询与下载



共找到 329 条与 气体加热器 相关的标准,共 22

1 Scope 1.1 Applicable equipment 1.1.1 Specific heaters This Standard applies to newly produced, direct-fired and indirect-fired construction heaters, hereinafter referred to as heaters, constructed entirely of new, unused parts and materials and primarily intended for temporary use in heating buildings or structures under construction, alteration, or repair. Products of combustion generated by direct-fired heaters are vented into the area being heated, whereas products of combustion generated by indirect-fired heaters are vented to the outdoors. Direct fired heaters may be installed indoors and optionally outdoors. Indirect-fired heaters may be installed indoors, outdoors, or both. Direct ground thawing heaters are for outdoor use only where heat is directed into the ground. The requirements of this Standard cover heaters with rated inputs up to and including 10 000 000 BTU/h (2930 kW). 1.1.2 Connection to ducts This Standard applies to self-contained heaters with or without integral means for air circulation and may be intended for connection to ducts. If a heater is designed to be utilized with ductwork, the heater is to be tested with the ductwork recommended by the manufacturer or at the maximum static pressure specified by the manufacturer. 1.1.3 Universal construction heaters This Standard applies to universal construction heaters (see Clause 3). 1.1.4 Fuel types for heaters This Standard applies to heaters for use with the following fuel types: a) natural gas; b) propane gas in the vapour phase; and c) propane gas in the liquid phase when the heater i) incorporates an integral vaporizer that meets the requirements outlined in Clause 6.7; and ii) meets all requirements for heaters for outdoor use outlined in Clause 5.19. 1.2 Non-applicable equipment This Standard does not apply to heaters employing a flameless catalytic combustion process. This Standard does not apply to heaters for use with liquid-phase fuel gases, except when the heater is for use with liquid propane and incorporates an integral vaporizer as outlined under applicable fuel types in Clause 1.1.

Gas-fired construction heaters

ICS
97.100.20
CCS
发布
2023-08-01
实施

本文件规定了带风冷燃烧室家用燃气快速热水器的评价指标、试验方法及评价等级。

Evaluation specifications for domestic gas fast water heater with air-cooled combustion chamber

ICS
97.100.20
CCS
C386
发布
2023-02-28
实施
2023-04-07

Gas heat pump — Ducted appliances — Testing and rating for performance

ICS
97.100.20
CCS
发布
2022-12-30
实施

Gas heat pumps — Non-ducted appliances — Testing and rating for performance

ICS
97.100.20
CCS
发布
2022-12-30
实施

1 范围 本标准规定了智能燃气快速热水器零冷水功能节能评价的评价指标及评价等级、评价规则及评价方法。 本标准适用于智能燃气快速热水器零冷水功能的节能评价,其他具有零冷水功能的热水器可参考执行。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB 6932  家用燃气快速热水器 GB 20665  家用燃气快速热水器和燃气采暖热水炉能效限定值及能效等级 GB/T 28219  智能家用电器通用技术要求 3 术语和定义 GB/T 28219界定的以及下列术语和定义适用于本文件。 3.1  智能燃气快速热水器  intelligent gas fast water heater 应用了智能化技术或具有了智能化能力/功能的燃气快速热水器。 注:以下简称“器具”。 3.2  零冷水功能  preheat function 通过水泵运转和器具燃烧预热用户用水管路中冷水的功能。 3.3  智能节能  intelligent energy saving 应用了智能化技术,通过用户习惯学习功能,使器具达到节能的效果。 3.4  用户习惯学习功能  user habit learning function 器具记忆用户使用时的温度、时间等习惯数据,主动(或自动)调整器具工作模式的能力。

Energy saving evaluation specification for preheat function of intelligent gas fast water heater

ICS
97.100.20
CCS
C385
发布
2022-11-03
实施
2022-11-03

本文件规定了空气分离设备用蒸汽加热器相关术语和定义、要求、制造与检验、出厂资料、标志、涂敷与运输包装。 本文件适用于空气分离设备中对纯化系统进行再生作用的蒸汽加热器(以下简称加热器),适用参数范围: a)蒸汽为饱和蒸汽或过热蒸汽,工作温度不大于350℃,工作压力不大于3.0MPa; b)再生气为空气或污氮气,工作压力不大于0.1MPa; 设计压力(MPa)与容积(m3)的乘积不大于500。

Specifications of steam heaters for air separation plants

ICS
97.100.20
CCS
C389
发布
2022-09-05
实施
2022-09-06

What is BS EN 613 - Closed-fronted gas-fired heaters about?   BS EN 613 is a standard that covers closed-fronted gas-fired heaters, enabling efficiency and performance in energy applications.   BS EN 613 specifies the requirements and test methods for the construction, safety, marking and rational use of energy.   BS EN 613 is applicable to types B 11AS , B 11BS , B 11CS , C 11 , C 31 and C 91 appliances and those that:   Are closed-fronted

Independent closed-fronted gas-fired type B11, type C11, type C31 and type C91 heaters

ICS
97.100.20
CCS
发布
2022-01-31
实施
2022-01-31

This document specifies the requirements and test methods for the construction, safety, marking and rational use of energy. This document is applicable to types B11AS, B11BS, B11CS, C11, C31 and C91 appliances (see 4.2) and those that: — are closed-fronted; — incorporate a natural draught burner; — are connected directly to an open flue or to a device to evacuate the products of combustion (open-flued appliances, balanced-flued appliances); — are wall mounted, free-standing or built-in; — have a nominal heat input not exceeding 20 kW (based on the net calorific value). This document is not applicable to: — open fronted appliances as specified in EN 13278:2013; — decorative fuel effect appliances as specified in EN 509:1999/A1:2003; — catalytic combustion appliances; — appliances in which the supply of combustion air and/or evacuation of products of combustion is achieved by mechanical means as specified in EN 1266:2002; — ducted-air appliances; — appliances installed by means of a closure plate (see 3.3.3.3). Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.

Independent closed-fronted gas-fired type B11, type C11, type C31 and type C91 heaters

ICS
97.100.20
CCS
发布
2021-12-22
实施
2022-03-31

Gas heat pumps — General requirements

ICS
97.100.20
CCS
发布
2021-05-31
实施

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2021-05-01
实施
2021-05-01

BS EN 509. Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2021-03-25
实施
2021-03-25

Decorative fuel-effect gas appliances

ICS
97.100.20
CCS
发布
2021-03-00
实施

1 范围 本标准规定了家用带电辅助加热燃气快速热水器的要求、试验方法、检验规则及标志、安装、包装、运输和贮存。 本标准适用于热负荷不大于70 kW家用带电辅助加热燃气快速热水器(以下简称热水器),不适用于燃气容积式热水器。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB 6932—2015  家用燃气快速热水器 3 术语和定义 GB 6932—2015界定的以及下列术语和定义适用于本文件。 3.1  家用带电辅助加热燃气快速热水器  domestic gas instantaneous water heater with electric auxiliary heating 带有一个或多个电辅助装置对流经电辅助装置的水进行加热的家用燃气快速热水器。 3.2  电辅助开启时循环预热噪声  cycle preheating noise at electric auxiliary heating 有内置水泵的机型,电辅助装置单独对管路进行循环预热时,所测得的噪声值。

Domestic gas instantaneous water heater with electric auxiliary heating

ICS
97.100.20
CCS
C385
发布
2021-02-05
实施
2021-05-20

1 范围 本标准规定了家用和类似用途储水式电热水器(简称“热水器”)的抗菌、除菌、阻垢功能的术语和定义、技术要求及试验方法。 本标准适用于具有抗菌、除菌、阻垢中一种或多种功能的家用和类似用途储水式电热水器。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB 4789.10—2016 食品安全国家标准 食品微生物学检验 金黄色葡萄球菌检验 GB 5749—2006 生活饮用水卫生标准 GB/T 5750.4—2006 生活饮用水标准检验方法 感官性状和物理指标 GB/T 5750.6—2006 生活饮用水标准检验方法 金属指标 GB/T 5750.12—2006 生活饮用水标准检验方法 微生物指标 GB/T 17218 饮用水化学处理剂卫生安全性评价 GB 21551.1—2008 家用和类似用途电器的抗菌、除菌、净化功能通则 GB 21551.2—2010 家用和类似用途电器的抗菌、除菌、净化功能 抗菌材料的特殊要求 GB 21551.3—2010 家用和类似用途电器的抗菌、除菌、净化功能 空气净化器的特殊要求 WS 628—2018 消毒产品卫生安全评价技术要求术语和定义 《消毒技术规范》(2002年版) 3 术语和定义 GB 21551.1—2008、GB 21551.2—2010、WS 628—2018 界定的以及下列术语和定义适用于本文件。 3.1  抗菌  antibacterial

Technical requirements and test methods of antibacterial and lime scale control function of electrical storage water

ICS
97.100.20
CCS
C385
发布
2020-11-09
实施
2021-02-24

1 Scope 1.1 This Standard applies to newly produced gas-fired outdoor infrared patio heaters (see Clause 3) hereinafter referred to as “heaters” or “appliances”, constructed entirely of new, unused parts and materials for use with: a) natural gas; or b) propane. 1.2 The heaters covered by this Standard are intended for installation in and heating of residential or nonresidential spaces. 1.3 Infrared patio heaters may be suspended overhead, angle-mounted overhead, wall-mounted, floormounted or for tabletop use. 1.4 Patio heaters intended for tabletop use are those limited to input ratings of 24 000 Btu/hr (7034 W) or less. These units incorporate an integral self-contained propane gas supply system consisting of a maximum of two disposable 1 lb (0.45 kg) fuel capacity cylinders and operating at pressures not greater than 5 psi (34.5 kPa). 1.5 Infrared patio heaters not intended for tabletop use may be for connection to a) a fixed fuel piping system operating at inlet gas pressures not exceeding 1/2 psi (3.5kPa); or b) an integral self-contained propane gas supply system, provided the appliance incorporates mounting means for the attachment of a maximum of one cylinder limited to a maximum of 20 lb (9.1 kg) of fuel operating at regulated outlet with i) pressure not exceeding 11 in wc (2.74 kPa); or ii) pressures in excess of 11 in wc (2.74 kPa) but not greater than 5 psi (34.5 kPa). 1.6 Clause 2 contains a list of standards specifically referenced in this Standard and sources from which these reference standards may be obtained. 1.7 Special construction provisions applicable to an appliance designed for use with an optional listed conversion kit are outlined under Annex D. 1.8 Special construction provisions applicable to infrared heaters designed to operate at altitudes over 2000 ft (610 m) are outlined in Annex E. 1.9 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. This Standard contains SI (Metric) equivalents to the yard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. (IEEE/ASTM-SI-10 is used as a guide in making metric conversion from yard/pound quantities.) If a value is given for a measurement and an equivalent value in other units, the first stated is to be regarded as the requirement. The given equivalent value may be approximate. If a value for a measurement and an equivalent value in other units are both specified as a quoted marking requirement, the first stated unit, or both shall be provided. 1.10 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Gas-fired outdoor infrared patio heaters

ICS
97.100.20
CCS
发布
2020-11-01
实施

What is BS EN 17175 - Gas-fired overhead radiant strip heaters about?    BS EN 17175 discusses gas-fired overhead radiant strip heaters and multiburner continuous radiant tube heater systems. BS EN 17175 specifies the requirements and test methods for the construction, safety, classification, marking, and efficiency of non-domestic gas-fired overhead radiant strips heaters and multi-burner continuous radiant tube heater systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.   For radiant strip heaters incorporating a single burner, BS EN 17175 is applicable to Type B22, B23, B52, B53, C12, C13, C32, C33 C52, and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.

Gas-fired overhead radiant strip heaters and multi-burner continuous radiant tube heater systems for non-domestic use. Safety and energy efficiency

ICS
97.100.20
CCS
发布
2020-02-29
实施
2020-02-29

1 范围 本标准规定了带CO催化功能的家用燃气快速热水器的技术要求、试验方法、检验规则及标志、安装、包装、运输和贮存。 本标准适用于热负荷不大于70 kW、带CO催化功能的家用燃气快速热水器(以下简称热水器)。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T 2828.1—2012  计数抽样检验程序 第1部分:按接收质量限(AQL)检索的逐批检验抽样计划 GB 6932—2015  家用燃气快速热水器 GB 20665—2015  家用燃气快速热水器和燃气采暖热水炉能效限定值及能效等级

Domestic gas instantaneous water heater with CO catalytic function

ICS
97.100.20
CCS
C213
发布
2019-12-09
实施
2020-04-26

1 Scope 1.1 This Standard applies to newly produced pool heaters (see Clause 3, Definitions), hereinafter referred to as pool heaters or appliances, constructed entirely of new, unused parts and materials, for heating non- potable water stored at atmospheric pressure, such as water in swimming pools, spas, hot tubs and similar applications: a) for use with natural gas; b) for use with manufactured gas; c) for use with mixed gas; d) for use with liquefied petroleum gases; e) for use with LP gas-air mixtures; f) for installation in applications intended to temper the entire flow of the primary circulating pool loop water prior to re-entering the pool; and g) for installation in applications for pool heaters intended to temper a portion of the primary circulating loop water diverted through the pool heater by mechanical means, and then re-enter and mix with the primary circulating loop water prior to entering the pool. 1.2 This Standard applies to pool heaters intended for installation at a distance less than 5 ft (1.52 m) from the inside surface of a pool or spa, hereinafter referred to as close proximity heaters (see Clause 3). 1.3 This Standard applies to pool heaters for indoor installation with draft hoods which are factory equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.4 This Standard applies to pool heaters of other than the direct vent type which are factory equipped with electrically operated or mechanically actuated automatic flue damper devices (see Clause 3, Definitions), hereinafter referred to as flue damper devices. 1.5 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.6 All references to psi throughout this Standard are to be considered gauge pressure unless otherwise specified. 1.7 Clause 7contains clauses that are unique to the United States. 1.8 Clause 8contains clauses that are unique to Canada. 1.9 Special construction clauses applicable to a water heater designed for use with an optional listed conversion kit are outlined under Annex D. 1.10 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard, and sources from which these reference standards may be obtained. 1.11 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Gas-fired pool heaters

ICS
97.100.20
CCS
发布
2019-11-01
实施

1 Scope 1.1 This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W): a) for use with natural gas; b) for use with propane; c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)]; d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)]; e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)]; f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)]. The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction. The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance. 1.2 Clauses 4and 5cover all vented gas fireplace heaters. In addition, Clauses 6and 7address the requirements specific to vented condensing gas fireplace heaters. ? 1.3 Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.4 If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.5 All references to “psi” throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.6 Clause 9, Items unique to the United States, contains provisions that are unique to the United States. 1.7 Clause 10, Items unique to Canada, contains provisions that are unique to Canada. 1.8 This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.9 Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional). 1.10 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. 1.11 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Vented gas fireplace heaters

ICS
97.100.20
CCS
发布
2019-11-01
实施

1 Scope 1.1 This Standard applies to portable type gas water heaters (herein after referred to as appliance or water heater) for use with propane, butane, or liquefied petroleum gases and mixtures thereof having: a) a regulated pressure; b) a non-regulated pressure. 1.2 Portable type water heaters and components employing materials or having forms of construction differing from those detailed in these provisions may be examined and tested according to the intent of the provisions, and if found to be satisfactorily equivalent, may be given recognition. 1.3 This Standard applies to portable water heater constructed entirely of new, unused parts. 1.4 All references to psi throughout this Standard are to be considered gauge pressures unless otherwise specified. 1.5 All accessories recommended by the manufacturer for use with appliances certified to this Standard are to be supplied and with the appliance. 1.6 A portable water heater is: a) for point of use (dishwashing, washing, showering, etc.) supply of either potable or non-potable hot water; b) not for permanent connection to inlet or outlet water lines; c) only intended for use outdoors and no connections may be provided for venting of combustion products via a chimney or vent system. 1.7 The water heater may be: a) tank type; b) automatic storage type; c) water-tube type; d) instantaneous type; or e) multifunction design such as an instantaneous-tube type (see Clause 3Definitions). 1.8 Portable water heaters are limited to a maximum input of 75,000 BTU/hr (21 980 W). V

Portable water heaters for outdoor use

ICS
97.100.20
CCS
发布
2019-11-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved