BS 2486-1997
蒸汽锅炉和热水器水处理推荐规范

Recommendations for treatment of water for steam boilers and water heaters


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:BS 2486-1997 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS 2486-1997 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
BS 2486-1997
发布日期
1997年02月15日
实施日期
1997年02月15日
废止日期
中国标准分类号
J98
国际标准分类号
13.060.01;91.140.65
发布单位
GB-BSI
被代替标准
95/521422 DC-1995 BS 2486-1978 97/124619 DC
适用范围
This British Standard gives recommendations for the control of water-side conditions of steam boilers and water heaters and also for the preparation of feed water for such plant. The following categories of water heating or steam-raising plant are covered: a) hot water systems as defined in 1.4; b) electrode boilers; c) shell (fire-tube) boilers operating at pressures up to 30 bar; d) water-tube boilers operating up to critical pressure; e) once-through boilers, including 'coil' and 'hairpin' types, operating up to, or above, the critical pressure. NOTE 1. Regulation 11 of the Pressure Systems and Transportable Gas Containers Regulations, 1989 [2] came into effect on 1 July 1994 and requires boiler users to provide operators with adequate and suitable instructions for the safe operation of the boiler, and to ensure that the boiler is not operated, except in accordance with these instructions. Guidance given in the Health and Safety Executive's Approved Code of Practice Safety of Pressure Systems [3] requires that instructions should cover, if appropriate, the feed water treatment. NOTE 2. The Control of Substances Hazardous to Health (COSHH) Regulations 1994 [1] require an assessment of the risk of exposure to substances hazardous to health and implication of the control measures needed to prevent, or if that is not reasonably practicable, adequately control such exposure. All sources of exposure in the workplace are covered including releases resulting from explosion or venting. For further information users are advised to consult the Approved Codes of Practice covering the control of substances hazardous to health and control of carcinogenic substances [4]. The recommendations are not directly appropriate for marine boilers which are separately addressed by BS 1170 Recommendations for treatment of water for marine boilers. The recommendations do not cover nuclear-powered steam generation plant. Analytical procedures and test methods are outside the scope of this standard. Annexes A to D provide additional useful information. note:2) 1 bar = 100 kPA.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号