13.080.10 土壤的化学特性 标准查询与下载



共找到 741 条与 土壤的化学特性 相关的标准,共 50

Soil quality-Determination of pH

ICS
13.080.10
CCS
发布
20201127
实施
20201127

ISO 16558-1 specifies a method for the quantitative determination of the total extractable volatile, the volatile aliphatic, and aromatic fractions of petroleum hydrocarbon content in field moist soil samples by gas chromatography with mass spectrometric detection. The aromatic f

Soil quality - Risk-based petroleum hydrocarbons - Part 1: Determination of aliphatic and aromatic fractions of volatile petroleum hydrocarbons using gas chromatography (static headspace method) (ISO 16558-1:2015 + Amd 1:2020); German version EN ISO 16558

ICS
13.080.10
CCS
发布
2020-11-01
实施

Soil quality - Risk-based petroleum hydrocarbons - Part 1: Determination of aliphatic and aromatic fractions of volatile petroleum hydrocarbons using gas chromatography (static headspace method) (ISO 16558-1:2015/Amd 1:2020); Amendment A1

ICS
13.080.10
CCS
发布
2020-11-00
实施
2020-11-01

1.1 This practice covers the collection of bare soil samples from areas around buildings and related structures using coring and scooping methods. 1.2 This practice may not be suitable for collection of soil samples from areas that are paved or otherwise covered with grass, mulch, or the like. See Guide E2115 or Practices E2271/E2271M or E3074/E3074M. 1.3 This practice does not address the sampling design criteria (that is, sampling plan that includes the number and location of samples) that are used for risk assessment and other lead hazard activities. 1.4 This practice contains notes that are explanatory and are not part of the mandatory requirements of this practice. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Field Collection of Soil Samples for Subsequent Lead Determination

ICS
13.080.10
CCS
发布
2020-09-01
实施

1.1 This practice covers the collection and documentation of quality control (QC) measurements for determining acceptable levels of instrumental performance when using field-portable energy-dispersive X-ray fluorescence spectrometry devices (XRFs) for the purposes of generating lead classification results from measurements on paint and other coating films within buildings and related structures. 1.1.1 This practice is not designed to determine the presence of a hazard as defined by authorities having jurisdiction in the United States or other jurisdictions. See Guide E2115 and the HUD Guidelines for more information. 1.2 QC procedures covered in this provisional practice include the performance of calibration checks, substrate bias checks, and specific instructions for documenting the collected data for later use in reporting the results. 1.3 No detailed operating instructions are provided because of differences among the various makes and models of suitable instruments. Instead, the analyst is to follow the instructions provided by the manufacturer of the particular XRF device or other relevant sources of information on XRF operation. 1.4 This practice contains notes which are explanatory and are not part of the mandatory requirements of this provisional practice. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) Devices

ICS
13.080.10
CCS
发布
2020-09-01
实施

This document specifies two methods for digestion of soil, treated biowaste, sludge and waste by the use of an aqua regia digestion. Digestion with aqua regia will not necessarily accomplish total decomposition of the sample. The extracted analyte concentrations may not necessarily reflect the total content in the sample but represent the aqua regia soluble metals under the condition of this test procedure. It is generally agreed that for environmental analysis purposes, the results are fit for the intended purpose to protect the environment. This document is applicable for the following elements: Aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), calcium (Ca), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), magnesium (Mg), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), phosphorus (P), potassium (K), selenium (Se), silver (Ag), sodium (Na), strontium (Sr), sulfur (S), tellurium (Te), thallium (Tl), tin (Sn), titanium (Ti), vanadium (V), and zinc (Zn). This document can also be applied for the digestion of other elements, provided the user has verified the applicability.

Soil, treated biowaste, sludge and waste — Digestion of aqua regia soluble fractions of elements

ICS
13.080.10
CCS
发布
2020-08-11
实施

Soil quality ― Determination of nitrate, nitrite and ammonium in field-moist soils by extraction with potassium chloride solution ―Part 1: Manual method

ICS
13.080.10
CCS
发布
2020-08-07
实施

Soil quality ― Determination of nitrate, nitrite and ammonium in field-moist soils by extraction with potassium chloride solution ―Part 1: Manual method

ICS
13.080.10
CCS
发布
2020-08-07
实施

本标准规定了土壤微生物量碳的测定。 本标准适用于各类土壤微生物量碳的测定。

Determination of soil microbial biomass carbon

ICS
13.080.10
CCS
N772
发布
2020-07-15
实施
2021-09-01

Soil quality. Risk-based petroleum hydrocarbons - Determination of aliphatic and aromatic fractions of volatile petroleum hydrocarbons using gas chromatography (static headspace method)

ICS
13.080.10
CCS
发布
2020-06-30
实施
2020-06-30

Soil quality - Risk-based petroleum hydrocarbons - Part 1: Determination of aliphatic and aromatic fractions of volatile petroleum hydrocarbons using gas chromatography (static headspace method) - Amendment 1 (ISO 16558-1:2015/Amd 1:2020)

ICS
13.080.10
CCS
发布
2020-06-17
实施
2020-09-30

Soil Sulfate Ion Determination by Cation Exchange Resin Method

ICS
13.080.10
CCS
B10
发布
2020-05-18
实施
2020-08-18

Soil Hydrolyzable Nitrogen Determination Kjeldahl Method

ICS
13.080.10
CCS
B10
发布
2020-05-18
实施
2020-08-18

BS ISO 15192. Characterization of soil and waste. Determination of Chromium(VI) in solid material by alkaline digestion and ion chromatography with spectrophotometric detection

ICS
13.080.10
CCS
发布
2020-04-17
实施
2020-04-17

Soil quality — Risk-based petroleum hydrocarbons — Part 1: Determination of aliphatic and aromatic fractions of volatile petroleum hydrocarbons using gas chromatography (static headspace method) — Ame

ICS
13.080.10
CCS
发布
2020-02-06
实施

1.1 This procedure covers the determination of (Tri-nbutyl)-n-tetradecylphosphonium chloride (TTPC) in a soil matrix by extraction with acetone, filtration, dilution with water, and analysis by liquid chromatography/tandem mass spectrometry. TTPC is a biocide that strongly adsorbs to soils.2 The sample extracts are prepared in a solution of 75 % acetone and 25 % water because TTPC has an affinity for surfaces and particles. The reporting range for this method is from 250 to 10 000 ng/kg. This analyte is qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry. 1.2 The method detection limit (Note 1) (MDL) and reporting range (Note 2) for the target analyte are listed in Table 1. NOTE 1—The MDL is determined following the Code of Federal Regulations, 40 CFR Part 136, Appendix B, as a guide utilizing solvent extraction of soil. Two-gram sample of Ottawa sand was utilized. A detailed process determining the MDL is explained in the reference and is beyond the scope of this standard to be explained here. NOTE 2—Reporting range concentration is calculated from Table 2 concentrations assuming a 50-µL injection of the Level 1 calibration standard for TTPC, and the highest level calibration standard with a 20-mL final extract volume of a 2-g soil sample. Volume variations will change the reporting limit and ranges. 1.2.1 The reporting limit in this test method is the minimum value below which data are documented as non-detects. Analyte detections between the method detection limit and the reporting limit are estimated concentrations and are not reported following this test method. The reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 2 for TTPC after taking into account a 2-g sample weight and a final extract volume of 20 mL in 75 % acetone/25 % water. The final extract volume is 20 mL because a 15-mL volume of acetone is added to each soil sample and only the liquid layer after extraction is filtered leaving the solid behind followed by the addition of 5 mL of water to the acetone extract. 1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in Soil by Multiple Reaction Monitoring Liquid Chromatography/Mass Spectrometry (LC/MS/MS)

ICS
13.080.10
CCS
发布
2020-02-01
实施

1.1 This test method covers analysis of nonylphenol (NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), octylphenol (OP), and bisphenol A (BPA), referred to collectively as target phenols (TPs), in soil, sediments, and biosolids by extraction with acetone, filtration, dilution with water, and analysis by liquid chromatography/ tandem mass spectrometry. The sample extracts are prepared in a solution of 75 % acetone and 25 % water because TPs have an affinity for surfaces and particles that is more pronounced at lower concentrations. The range of applicability of the test method is shown in Table 1. The method may be extended outside of these ranges depending on additional performance studies not undertaken here. 1.2 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Analysis of Target Phenols (TPs) in Soil by Multiple Reaction Monitoring Liquid Chromatography/Mass Spectrometry (LC/MS/MS)

ICS
13.080.10
CCS
发布
2020-02-01
实施

What is ISO 21226 - Soil screening using soil magnetometry about?    ISO 21226 discusses soil quality with a focus on soil screening using soil magnetometry.     ISO 21226 specifies methods for the measurements of magnetic susceptibility of soils (κ) as an indicator of potential soil pollution/contamination with trace elements associated with technogenic magnetic particles (TMPs).    ISO 21226 describes related procedures, protocols, and guidelines to be applied as a screening geophysical method of determination of soil pollution with trace elements. The results of measurements are used for preparing the maps of the magnetic susceptibility of soils in the area of interest.    ISO 21226 is applicable to screening all TMPs-related anthropogenic emission sources including long-range transport of airborne elements, of which TMPs are carriers and indicators.    Note: ISO 21226 is not applicable to screening anthropogenic emissions not associated with TMPs, e.g., organic pollutants ...

Soil quality. Guideline for the screening of soil polluted with toxic elements using soil magnetometry

ICS
13.080.10
CCS
发布
2019-12-31
实施
2019-12-31

本标准规定了测定土壤和沉积物中铊的石墨炉原子吸收分光光度法。 本标准适用于土壤和沉积物中铊总量的测定。 当称样量为 0.5 g,定容体积为 50 ml 时,本方法检出限为 0.1 mg/kg,测定下限为0.4 mg/kg

Soil and sediment—Determination of thallium —Graphite furnace atomic absorption spectrophotometry

ICS
13.080.10
CCS
Z18
发布
2019-12-31
实施
2020-06-30

Soil quality — Determination of perchlorate in soil using ion chromatography

ICS
13.080.10
CCS
发布
2019-12-30
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号