23.060 阀门 标准查询与下载



共找到 964 条与 阀门 相关的标准,共 65

Sluice valves for water works

ICS
23.060
CCS
发布
2015-12-29
实施

Inspection and Testing of Valves Part 1: Americas Series

ICS
23.060
CCS
J16
发布
2015-09-15
实施
2015-10-15

Inspection and testing of valves Part 2: European series

ICS
23.060
CCS
J16
发布
2015-09-15
实施
2015-10-15

This part of IEC 60534 defines the testing and reporting of the step response of control valves that are used in throttling closed-loop control applications. A control valve consists of the complete, ready-to-use assembly of the control valve body, the actuator, and any required accessories. The most probable accessory is a valve positioner. NOTE For background, refer to technical report ANSI/ISA-TR75.25.02 [6]1. The object of this standard is to define how to test, measure, and report control valve response characteristics in an open-loop environment. This information can be used for process control applications to determine how well and how fast the control valve responds to the control valve input signal. This standard does not define the acceptable control valve performance for process control nor does it restrict the selection of control valves for any application. If this standard is used for evaluation or acceptance testing, the parties may agree to documented variations from these requirements. The information using the defined test methods is specifically applicable to closed-loop feedback control but may have some application to open-loop control applications. It does not address valves used in on-off control service. Tests specified in this standard may not be sufficient to measure the performance required for all applications. Not all control valve applications will require this testing.

Industrial-process control valves - Part 9: Test procedure for response measurements from step inputs

ICS
23.060
CCS
发布
2015-09-03
实施

This part of IEC 60534 specifies face-to-face (FTF) and centre-to-face (CTF) dimensions for given nominal sizes and pressure ratings of flanged, two-way, globe-type, straight pattern and angle pattern control valves. The nominal sizes included are DN 15 to DN 400 for straight pattern control valves and DN 25 to DN 400 for angle pattern control valves.

Industrial-process control valves - Part 3-1: Dimensions - Face-to-face dimensions for flanged, two-way, globe-type, straight pattern and centre-to-face dimensions for flanged, two-way, globe-type, angle pattern control valves

ICS
23.060
CCS
发布
2015-09-03
实施

This part of IEC 60534 is intended to permit a variety of positioning devices, which respond to a rotary motion, to be mounted on the actuator of a control valve, either directly or by employing an intermediate mounting bracket. This standard is applicable where interchangeability between actuators and positioners is desired. a) The standardized mounting in this standard defines the interface between the positioner and a part of the actuator having a rotary movement proportional to the control valve travel. b) This standard also covers the direct connection between the positioner feedback and the shaft (or its axial extension) of a rotary control valve. In such cases, the feedback rotation is coincident with the valve angular travel. c) The standardized mounting applies to those rotary actuators in which the rotary part mentioned in item a) has a maximum travel of 90°. Such a travel is coincident with the valve travel when a direct connection (see item b)) is performed. d) The standardized mounting is divided into two options. Figure 1 shows the basic design and defines the minimum requirements an actuator must fulfill to adapt most common positioners. The universal design in figure 2 offers more variations of positioner adaptation and positioner feedback connection. The positioner manufacturer should state which mounting design is required.

Industrial-process control valves - Part 6-2: Mounting details for attachment of positioners to control valves - Positioner mounting on rotary actuators

ICS
23.060
CCS
发布
2015-09-03
实施

1.1 This Standard applies to manual lever operated gas shut-off valves, sizes NPS ¼ inch to 8 inch, of metallic construction with welded, or flanged, or threaded ends other than pressure lubricated designs for use with natural gas, manufactured gas, and liquefied petroleum gases (distributed as vapour with or without the admixture of air), or mixtures thereof that are suitable for use between service temperatures of -60 °C to 180 °C (-76°F to 356°F) over a pressure range of 0 to 860 kPa (125 psig) and that withstand field pressure testing to a maximum permissible pressure of 1290 kPa (187 Psig). Notes: 1) Valves covered by this Standard may be used on “digester gas” (methane produced during sewage treatment), but because of entrained contaminants their use is to be subject to agreement between the manufacturer and the purchaser. 2) Valves covered by this Standard may not be used on “sour gas” (gas with entrained hydrogen sulphide) without modification(s). Manufacturers should be consulted for their recommendation(s). 1.2 All valves covered by this Standard will be limited as to the service temperature and/or special provisions in accordance with the following designations and descriptions in Clauses 5 through 9. Clause 5 -30 °C to 65 °C (-22°F to 149°F) Clause 6 -40 °C to 65 °C (-40°F to 149°F) Clause 7 -60 °C to 65 °C (-76°F to 149°F) Clause 8 -30 °C to 120 °C (-22°F to 248°F) Clause 9 -30 °C to 180 °C (-22°F to 356°F) 1.3 All references to psi (kPa) throughout this Standard are considered as gauge pressure unless otherwise specified. 1.4 This Standard contains SI (Metric) units corresponding to the yard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. (IEEE/ASTM SI 10, American National Standard for Metric Practice, or ISO 80000-1:2009, Quantities and units – Part 1: General, is used as a guide in making metric conversion from yard/pound quantities.) If a value for a measurement and a corresponding value in other units are stated, the first stated value is to be regarded as the requirement. The given corresponding value may be approximate. If a value for a measurement and a 9corresponding value in other units are both specified as a quoted marking requirement, the first stated unit, or both, are to be provided. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Lever operated non-lubricated gas shut-off valves

ICS
23.060
CCS
发布
2015-01-01
实施

This part of IEC 61514 specifies design reviews and tests intended to measure and determine the static and dynamic performance, the degree of intelligence and the communication capabilities of single-acting or double-acting intelligent valve positioners. The tests may be applied to positioners which receive standard analogue electrical input signals (as specified in IEC 60381) and/or digital signals via a data communication link and have a pneumatic output. An intelligent valve positioner as defined in Clause 3 is an instrument that uses for performing its functions digital techniques for data processing, decision-making and bi-directional communication. It may be equipped with additional sensors and additional functionality supporting the main function. The performance testing of an intelligent valve positioner needs to be conducted with the positioner mounted on and connected to the actuator/valve assembly the positioner is to be used on. The specific characteristic parameters of these combinations such as size, stroke, friction (hysteresis), type of packing, spring package and supply pressure for the pneumatic part, should be carefully chosen and reported, since the performance of a positioner is greatly dependent on the used actuator. The methods of evaluation given in this standard are intended for testing laboratories to verify equipment performance specifications. The manufacturers of intelligent positioners are urged to apply this standard at an early stage of development. This standard is intended to provide guidance for designing evaluations of intelligent valve positioners by providing: – a checklist for reviewing their hardware and software design in a structured way; – test methods for measuring and qualifying their performance under various environmental and operational conditions; – methods for reporting the data obtained. When a full evaluation, in accordance with this standard, is not required or possible, the tests which are required should be performed and the results should be reported in accordance with the relevant parts of this standard. In such cases, the test report should state that it does not cover the full number of tests specified herein. Furthermore, the items omitted should be mentioned, to give the reader of the report a clear overview. The standard is also applicable for non-intelligent microprocessor-based valve positioners without means for bi-directional communication. In that case an evaluation should be reduced to a limited programme of performance testing and a short review of the construction.

Industrial process control systems - Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly

ICS
23.060
CCS
发布
2014-12-25
实施

This International Standard specifies tests designed to determine the static and dynamic performance of single-acting or double-acting positioners. The tests may be applied to positioners which receive standard analogue input signals (as specified in IEC 60381 and IEC 60382) and have a pneumatic output. NOTE For positioners with pulsed or digital input signals, equivalent criteria may be applied. The methods described may not fully apply to positioners with digital controllers or positioners with pulsed outputs. Testing may be conducted either on a positioner alone, independently of an actuator, or on a positioner mounted and connected to a specific actuator, as a combined unit. The text makes clear where different approaches are required. The methods of evaluation given in this standard are intended for use by manufacturers to determine the performance of their products, and by users, or independent testing establishments, to verify manufacturers' performance specifications. The closest liaison should be maintained between the evaluating body and the manufacturer. Note should be taken of the manufacturer's specifications for the instrument when the test programme is being decided, and the manufacturer should be invited to comment on both the test programme and the results. His comments on the results should be included in any report produced by the testing organization. This standard is intended to provide definitions of positioner elements, actions, and characteristics, to specify uniform methods of measuring performance errors and effects of influence quantities on those characteristics, and to describe methods of reporting and evaluating the results of the measurement data obtained. The test conditions described in this publication (for example range of ambient temperatures and power supply) relate to conditions which commonly arise in use. Consequently, the values specified shall be used where no other values are specified by the manufacturer or user. If other values are used, they should be stated. It is recognized that the manufacturer's specifications and instructions for installation and operation should apply during all steps. The tests specified in this standard are not necessarily sufficient for instruments specifically designed for unusually arduous conditions. Conversely, a reduced series of tests may serve adequately for instruments designed to perform within a more limited range of conditions. When a full evaluation, in accordance with this standard, is not required or possible, those tests which are required should be performed and the results reported in accordance with the relevant parts of this standard. In such cases, the test report should state that it does not cover the full number of tests specified herein.

Industrial-process control systems - Methods of evaluating the performance of valve positioners with pneumatic outputs

ICS
23.060
CCS
发布
2014-12-25
实施

Motorized valve for fan coil units

ICS
23.060
CCS
J72
发布
2014-12-15
实施
2014/12/15

Motorized valve for fan coil units

ICS
23.060
CCS
发布
2014-12-15
实施

이 표준은 나사로 직접 체결된 차단장치(매니폴드)를 갖는 차동압력(형) 측정기(기구)에 적용할 수 있다.이 표준은 38 ℃에서 41.3 MPa(413 bar)의 최대 허용 동작압력을 위한 상대 치수와 허용공차, 나사산, 나사, 개스킷을 규정한다.이 표준은 계기와 매니폴드 사이에 추가적인 밀봉 요소(어댑터)를 제공하는 조립에는 적용하지 않는다.계기의 장착이 가능한 한쪽 면에 차단장치를 장착해야 하며, 모든 연결은 이 표준에 부합해야 한다.플랜지 접속된 축이음과 같은 요소는 공급자와 최종 사용자의 재량에 따라 표준화를 높이기 위해 이 표준, 또는 이 표준의 각 부들을 적용할 수 있다.이 표준은 190 N/mm2 이상의 항복강도를 갖는 금속재질로 생산된 계기와 매니폴드 플랜지에 대해서만 유효하다.?

Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41.3 MPa)

ICS
23.060
CCS
发布
2014-10-02
实施
2014/10/2

Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41.3 MPa)

ICS
23.060
CCS
发布
2014-10-02
实施

本标准规定了电站阀门的压力-温度额定值、一般要求、订货要求、设计及制造、材料、焊接、热处理、返修、检验、试验、标志、涂漆、供货、包装、交付文件、阀门安装、调试、质量保证和环境保护等要求。本标准适用于法兰、螺纹和焊接端连接的铸造、锻造和组焊阀门的设计、制造与验收,包括超(超)临界及以下参数用的截止阀、闸阀、堵阀、止回阀、安全阀、泄放阀、调节阀、减压阀、减温减压阀、节流阀、给水分配阀、排污阀、快速启闭阀、碟阀、球阀、循环泵出口阀、闭锁阀、高加三通阀、抽气逆止阀等各类火力发电机组用钢制阀门和镍基合金阀门,其参数范围为:PN系列:--公称压力小于或等于80MPa,最高工作温度小于或等于430℃ ;--工作压力小于或等于35MPa,最高工作温度小于或等于625℃ ;--工作压力小于或等于8MPa,最高工作温度小于或等于648℃。Class系列:--压力级别Class 150至Class 4500。其他蒸汽参数机组和工业锅炉、余热锅炉和其他特种设备上用的阀门也可参照采用。

Valves for power station

ICS
23.060
CCS
J16
发布
2014-06-29
实施
2014-11-01

Hydraulic fluid power-Identification of valve ports,subplates, control devices and solenoids

ICS
23.060
CCS
发布
20131230
实施
20131230

4-way reversing valves for heat pump

ICS
23.060
CCS
发布
2013-12-30
实施

Hydraulic fluid power-Identification of valve ports,subplates, control devices and solenoids

ICS
23.060
CCS
发布
2013-12-30
实施

Scope 1.1 This Standard applies to electrically operated, general-purpose valves* and safety valves* that are intended to be used in ordinary locations in accordance with the Canadian Electrical Code, Part I, for the control of fluids (e.g., air, gases, oils, refrigerants, steam, water, etc.), and rated 600 V and less. * For convenience, the shorter term "valve" is used where the same requirements apply to both general-purpose and safety valves. 1.2 This Standard also applies to valves intended to be incorporated into equipment that is subject to the requirements of the Canadian Electrical Code, Part II. 1.3 This Standard also applies to electrically powered mechanisms that are designed to provide the signals needed for monitoring valve operation from a remote location and to electrically powered valve actuators*, that are designed to be fitted to valves. * For convenience the term valve includes valve actuator unless otherwise stated. 1.4 This Standard contains requirements for electrical features of valves and requirements for mechanical features of valves that affect their safe operation. 1.5 This Standard does not include requirements for mechanical and operational features that do not directly affect the safe operation of a valve. 1.6 With respect to construction and tests of electrical features, the requirements of this Standard complement those of ANSI Z21.21/CSA 6.5. 1.7 This Standard does not apply to water valves of connection size larger than 2-inch pipe size or pressure rating above 1600 kPa (232 psi) for valve bodies of thermo plastic material. 1.8 Electrically operated damper actuators are evaluated to the requirements of CSA C22.2 No. 24. 1.9 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.10 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Electrically operated valves

ICS
23.060
CCS
发布
2013-12-01
实施

本规范规定了石油化工通用铸铁、碳素钢、铬钼合金钢、不锈钢和铜、铝、钛、镍等部分有色金属及其合金的闸阀、截止阀、止回阀、蝶阀、球阀、旋塞阀、隔膜阀、疏水阀、减压阀以及安全阀等阀门安装前的检验及管理要求。本规范适用于石油化工工程中公称压力不大于PN420 (CL2500),设计温度-196℃~850℃的石油化工工业管道阀门检验与管理,不适用于长输管道的阀门。

Specification for valves inspection and management in petrochemical industry

ICS
23.060
CCS
P72
发布
2013-10-17
实施
2014-03-01

IEC 61514-2:2013 specifies design reviews and tests intended to measure and determine the static and dynamic performance, the degree of intelligence and the communication capabilities of single-acting or double-acting intelligent valve positioners. The tests may be applied to positioners which receive standard analogue electrical input signals (as specified in IEC 60381) and/or digital signals via a data communication link and have a pneumatic output. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The significant changes with respect to the previous edition are: The standard has been optimized for usability and the test procedures have been reviewed regarding applicability for use in test facilities. Impractical test procedures were removed or modified.

Industrial process control systems - Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly

ICS
23.060
CCS
发布
2013-09-06
实施
2013-11-01 (7)



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved