71.080.10 脂族烃 标准查询与下载



共找到 350 条与 脂族烃 相关的标准,共 24

1.1 This specification covers the three grades of 1,1,2trichloro 1,2,2-trifluoroethane2 typically needed in various industries. It may be used as a reference document by purchasers or by persons establishing in-house, 1,1,2-trichloro 1,2,2trifluoroethane recovery programs. 1.2 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Reclaimed 1,1,2-Trichloro 1,2,2-Trifluoroethane

ICS
71.080.10
CCS
发布
2020-04-01
实施

工业用高纯甲基环戊二烯二聚体产品应符合表1的技术要求。 表1 工业用高纯甲基环戊二烯二聚体的技术要求                          项  目                                                        指  标 外观                                                                     透明均一液体,无机械杂质 含量,w%(质量分数)        ≥                                                  99.0 色度(铂-钴),号               ≤                                                  20 水分,mg/kg                          ≤                                                  200

High purity methylcyclopentadiene dimer for industrial use

ICS
71.080.10
CCS
C261
发布
2019-12-03
实施
2019-12-03

工业用高纯双环戊二烯产品应符合表1的技术要求。 表1 工业用高纯双环戊二烯的技术要求                项  目                                      指  标                                                      优等品   合格品 外观 (温度≥40℃)            透明均一液体,无机械杂质 含量, w%(质量分数)        ≥      99.0      97.0 色度(铂-钴),号                ≤        10         20 水分,mg/kg                        ≤        200         250

High purity dicyclopentadiene for industrial use

ICS
71.080.10
CCS
C261
发布
2019-12-03
实施
2019-12-03

1.1 This test method covers the quantitative measurement, either in the laboratory or in the field, of how easily asphaltenecontaining heavy fuel oils diluted in toluene phase separate upon addition of heptane. The result is a separability number (%). See also Test Method D7061. 1.2 The test method is limited to asphaltene-containing heavy fuel oils. ASTM specification fuels that generally fall within the scope of this test method are Specification D396, Grade Nos. 4, 5, and 6, Specification D975, Grade No. 4-D, and Specification D2880, Grade Nos. 3-GT and 4-GT. Refinery fractions from which such blended fuels are made also fall within the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Measuring n-Heptane Induced Phase Separation of Asphaltene from Heavy Fuel Oils as Separability Number by an Optical Device

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This test method covers the determination of butadiene1,3 purity and impurities such as propane, propylene, isobutane, n-butane, butene-1, isobutylene, propadiene, transbutene-2, cis-butene-2, butadiene-1,2, pentadiene-1,4, and, methyl, dimethyl, ethyl, and vinyl acetylene in polymerization grade butadiene by gas chromatography. Impurities including butadiene dimer, carbonyls, inhibitor, and residue are measured by appropriate ASTM procedures and the results used to normalize the component distribution obtained by chromatography. NOTE 1—Other impurities present in commercial butadiene must be calibrated and analyzed. Other impurities were not tested in the cooperative work on this test method. NOTE 2—This test method can be used to check for pentadiene-1,4 and other C5s instead of Test Method D1088. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.1 and 9.3. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This test method covers the determination of peroxides in butadiene. 1.2 This test method covers the concentrations range of 1 mg ⁄kg to 10 mg ⁄kg as available oxygen. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Determination of Peroxides in Butadiene

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This test method covers the determination of butadiene dimer (4-vinylcyclohexene-1) and styrene in butadiene concentrates, both recycle and specification grade. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 6 and 8. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Butadiene Dimer and Styrene in Butadiene Concentrates by Gas Chromatography

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This guide covers the analysis of 1,3–butadiene products produced in North America. It includes possible components and test methods, both ASTM and other, either actually used or believed to be in use, to test for these components. This guide is not intended to be used or construed as a set of specifications for butadiene products. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Guide for Analysis of 1,3–Butadiene Product

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This test method covers the quantitative measurement, either in the laboratory or in the field, of how easily asphaltenecontaining heavy fuel oils diluted in toluene phase separate upon addition of heptane. This is measured as a separability number (%) by the use of an optical scanning device. 1.2 The test method is limited to asphaltene-containing heavy fuel oils. ASTM specification fuels that generally fall within the scope of this test method are Specification D396, Grade Nos. 4, 5, and 6, Specification D975, Grade No. 4-D, and Specification D2880, Grade Nos. 3-GT and 4-GT. Refinery fractions from which such blended fuels are made also fall within the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Measuring n-Heptane Induced Phase Separation of Asphaltene-Containing Heavy Fuel Oils as Separability Number by an Optical Scanning Device

ICS
71.080.10
CCS
发布
2019-12-01
实施

Standard Test Method for Measuring n-Heptane Induced Phase Separation of Asphaltene-Containing Heavy Fuel Oils as Separability Number by an Optical Scanning Device

ICS
71.080.10
CCS
发布
2019-12-01
实施

1.1 This test method covers the determination of the purity of cyclohexane by gas chromatography. 1.2 This test method has been found applicable to the measurement of impurities such as those found in Table 1, which are impurities that may be found in cyclohexane. The impurities can be analyzed over a range of 1 to 400 mg/kg by this method, but may be applicable to a wider range. 1.3 The limit of detection is 1 mg/kg. 1.4 In determining the conformance of the test results using this test method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)

ICS
71.080.10
CCS
发布
2019-11-01
实施

Standard Test Method for Trace Carbonyl Sulfide in Propylene by Gas Chromatography

ICS
71.080.10
CCS
发布
2019-05-01
实施

1.1 The ASTM Butadiene Measurement Tables are for use in the calculation of quantities of butadiene. The accompanying Tables 1-3 cover the normal operating ranges for the reduction of observed relative density and volume to 15.556/ 15.556 °C (60/60 °F) and for the calculation of weight-volume relationships of butadiene. 1.2 These tables are applicable to both butadiene and butadiene concentrates (minimum of 60 % butadiene). NOTE 1—These tables replace the existing tables in the National Institute of Standards and Technology Letter Circulars LC-736 and LC-757 and the Rubber Reserve Corp., Butadiene Laboratory Manual. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard ASTM Butadiene Measurement Tables

ICS
71.080.10
CCS
发布
2018-10-01
实施

本标准规定了工业用2,5-二甲基-2,5-双(叔丁基过氧基)己烷的要求、试验方法、检验规则、标志、包装、运输、贮存。 本标准适用于以2,5-二甲基2,5-己二醇、双氧水、叔丁醇和硫酸为原料,经反应制得的工业用2,5-二甲基-2,5-双(叔丁基过氧基)己烷。

2,5-Dimethyl-2,5-Bis(t-butyl peroxy)hexane for industrial use

ICS
71.080.10
CCS
C261
发布
2018-08-10
实施
2019-08-01

1.1 This guide covers a list of the major grades of propylene concentrates produced in North America. It includes possible components and test methods, both ASTM and other, either actually used, or believed to be in use, to test for these properties. This guide is not intended to be used or construed as a set of specifications for any grade of propylene concentrate. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Guide for Analysis of Propylene Concentrates

ICS
71.080.10
CCS
发布
2018-07-01
实施

Standard Test Method for Determination of Hydrocarbon Impurities in High Purity Propylene by Gas Chromatography

ICS
71.080.10
CCS
发布
2018-06-01
实施

1.1 This test method covers the determination of the purity of cyclohexane by gas chromatography. 1.2 This test method has been found applicable to the measurement of impurities such as those found in Table 1, which are impurities that may be found in cyclohexane. The impurities can be analyzed over a range of 1 to 400 mg/kg by this method, but may be applicable to a wider range. 1.3 The limit of detection is 1 mg/kg. 1.4 In determining the conformance of the test results using this test method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)

ICS
71.080.10
CCS
发布
2018-01-01
实施

1.1 This test method covers the determination of the purity of cyclohexane by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique. 1.2 This test method has been found applicable to the measurement of impurities such as those found in Table 1, which are impurities that may be found in cyclohexane. The impurities can be analyzed over a range of 3 to 200 mg/kg by this method, but may be applicable to a wider range. 1.3 The limit of detection is 1 mg/kg. 1.4 In determining the conformance of the test results using this test method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard)

ICS
71.080.10
CCS
发布
2018-01-01
实施

1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. 1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, ethylbenzene, t-butylbenzene, n-propylbenzene, alpha-methylstyrene, sec-butylbenzene, and diisopropylbenzene, which are common to the manufacturing process of isopropylbenzene. The limit of quantitation for these impurities averages 0.0030 wt.% based on the data in Table 2, while the limit of detection for these impurities averages 0.0010 wt.%. This method has been found applicable for concentrations of various components up to 0.0571 wt.%. 1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography

ICS
71.080.10
CCS
发布
2018-01-01
实施

Ethylene and propylene for industrial use — Determination of acetone, acetonitrile, propan-2-ol and methanol — Gas chromatographic method

ICS
71.080.10
CCS
发布
2017-12-29
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号