K40 输变电设备综合 标准查询与下载



共找到 277 条与 输变电设备综合 相关的标准,共 19

Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests (IEC 61558-1:2005); German version EN 61558-1:2005, Corrigenda to DIN EN 61558-1 (VDE 0570-1):2006-07; German version CENELEC-Cor. :2006 t

ICS
29.180
CCS
K40
发布
2008-12
实施

1.1 These requirements cover medium voltage power conversion equipment that controls and transfers power to motors. These requirements also cover power-supply modules, input/output modules, and electronic solid state switching devices, for use with power conversion equipment. 1.2 These requirements cover equipment rated 1501 volts to 15,000 volts. 1.3 This equipment has not been investigated for use in hazardous locations as defined by the National Electrical Code, NFPA 70. 1.4 These requirements do not cover solid state reduced voltage motor controllers (soft starters). 1.5 These requirements do not cover low voltage power conversion equipment rated 1500 volts and below. This type of equipment is covered by the Standard for Power Conversion Equipment, UL 508C.

OUTLINE OF INVESTIGATION FOR MEDIUM VOLTAGE POWER CONVERSION CONTROLLERS Issue Number: 1

ICS
CCS
K40
发布
2008-07-29
实施

Device function numbers for control devices and equipment of electrical installations of directcurrent substaion

ICS
CCS
K40
发布
2008-07-25
实施

Device function numbers for control devices and equipment of electrical installations of hydraulic power station

ICS
CCS
K40
发布
2008-07-25
实施

Device function numbers for control devices and equipment of electrical installations of alternatingcurrent substaion

ICS
CCS
K40
发布
2008-07-25
实施

Device function numbers for control devices and equipment of electrical installations of thermal power station

ICS
CCS
K40
发布
2008-07-25
实施

This Standard specifies requirements for the design and the erection of electrical power installations (stations) in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide for safety of persons and proper functioning of the installation. This Standard applies to indoor substations, generating stations, and fenced outdoor supply stations and substations (including supply substations on customer premises). For the purpose of interpreting this Standard, an electrical power installation is considered to be one of the following: (a) a substation, i.e., a closed electrical operating area in a transmission or distribution network; or (b) one or more generating station(s) located on a single site. The installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded from the scope of this Standard. Connections between closed electrical areas (including substations) located on the same site are taken to be part of the installation, except where such connections form part of a transmission or distribution system. The electrical power installation includes, but is not limited to, the following equipment: – rotating electrical machines; – switchgear; – transformers and reactors; – converters; – cables; – lines; – wiring systems; – batteries; – capacitors; – earthing systems; – buildings and fences that are part of a closed electrical operating area; – associated protection, control, and auxiliary systems; and – large air-type core reactors. Note: In general, a Standard for an item of equipment takes precedence over this Standard. This Standard does not apply to the design and erection of any of the following: – overhead and underground lines between separate installations; – pad-mounted tamper-proof enclosed equipment installations; – underground distribution system installations; – pole-mounted installations; – electric railways (but not the substation feeding a railway system); – mining equipment and installations; – fluorescent lamp installations; – installations on ships and off-shore installations; – electrostatic equipment; – test sites; or – medical equipment, e.g., medical x-ray equipment. This Standard does not apply to the design of factory-built, type-tested switchgear for which separate Standards exist. The requirements for carrying out live working on electrical installations are beyond the scope of this Standard.

Power installations exceeding 1 kV a.c. ?Part 1: Common rules First Edition

ICS
CCS
K40
发布
2008-07-01
实施

Maintenance of installations and equipment of electrical energy supply networks - Part 1: System aspects and procedures

ICS
29.240.01
CCS
K40
发布
2008-07-01
实施
2008-07-01

Low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Electrical safety. Equipment for testing, measuring or monitoring of protective measures. Part 5. Resistance to earth

ICS
17.220.20
CCS
K40
发布
2008
实施
2009-01-01

The standard defines the functions and features to be provided in substation intelligent electronic devices (IEDs) to accommodate critical infrastructure protection programs. The standard addresses security regarding the access, operation, configuration, firmware revision and data retrieval from an IED. Encryption for the secure transmission of data both within and external to the substation is not part of this standard.

Standard for Substation Intelligent Electronic Devices (IED) Cyber Security Capabilities

ICS
CCS
K40
发布
2008
实施

New procedures for short-circuit testing of station, intermediate and distribution arresters would replace existing pressure-relief and short-circuit test procedures for these classes of arrester.

Standard for Metal-Oxide Surge Arresters for AC Power Circuits ( 1 kV) - Amendment: Short-Circuit Tests for Station, Intermediate and Distribution Arresters

ICS
CCS
K40
发布
2008
实施

Corrections to C62.21-2003 are made.

Guide for the Application of Surge Protective Equipment on AC Rotating Machinery 1000 Volts and Greater - Corrigendum 1: Replace Table 2 and Annexes A.1 and A.2

ICS
29.120.50
CCS
K40
发布
2008
实施

This specification covers ACB, low voltage, electric power, air circuit breakers with removable onstruction, their stationary component (cradle), and attachments for shipboard use.

CIRCUIT BREAKERS, ACB, LOW VOLTAGE, ELECTRIC POWER, AIR, REMOVABLE CONSTRUCTION, GENERAL SPECIFICATION FOR

ICS
29.120.30
CCS
K40
发布
2007-06-28
实施

This supplement forms a part of MIL-DTL-17587C(SH), dated 28 June 2007.

CIRCUIT BREAKERS, ACB, LOW VOLTAGE, ELECTRIC POWER, AIR, REMOVABLE CONSTRUCTION, GENERAL SPECIFICATION FOR

ICS
29.120.30
CCS
K40
发布
2007-06-28
实施

Recommends testing procedures, general data gathering formats, and general data reduction formats for field monitoring of overhead conductor vibration. Also provides some background information on technical aspects of vibration field measurements for overhead conductors, techniques for evaluating the severity of conductor vibration including amplitude and frequency, and some effects on conductor performance and life.

Guide for Aeolian Vibration Field Measurements of Overhead Conductors

ICS
17.100;13.160
CCS
K40
发布
2007-05-24
实施

Covering three-phase ac systems from 1kV to 800 kV, provides recommended electrical operating and safety clearances and insulation levels in air-insulated electric supply substation; addresses insulation coordination procedures; provides design procedures for the selection and coordination of the insulation levels within the station as they relate to substation clearances; and addresses how reduced clearances in high-voltage ac substations will allow for compact bus arrangements and substation voltage uprating applications.

Guide for Recommended Electrical Clearances and Insulation Levels in Air Insulated Electrical Power Substations

ICS
27.100;29.035.99
CCS
K40
发布
2007-04-26
实施

Correction Sheet to IEEE Std 80-2000

Guide for safety in AC substation grounding

ICS
29.120.50
CCS
K40
发布
2007-02
实施

本标准规定了变电设备巡检系统的建设原则、架构、使用流程、功能和巡检终端设备配置要求。 本标准适用于变电设备巡检系统的设计、建设、验收和应用。

Patrol system for power transformation facilities

ICS
29.240.10
CCS
K40
发布
2006-12-17
实施
2007-05-01

This document was prepared in the UIC Infrastructure Forum by the Traction and Energy Experts Group to provide Infrastructure Managers (IM) with guidelines for maintenance of overhead contact lines (OCL) based on uniform criteria and common objectives. OCL have been divided into their main components or parts to be taken into account for planning and performing maintenance operations. At the same time the main parameters to be checked, measured or observed and the operations/interventions to be carried out have been identified, as well as the data that should be examined to evaluate the condition of the OCL and to ensure expected performance.

Maintenance guidelines for overhead contact lines

ICS
CCS
K40
发布
2006-10-01
实施

This supplement forms a part of MIL-DTL-17361G(SH) dated 19 September 2006.

CIRCUIT BREAKER TYPES AQB/NQB, AIR, ELECTRIC, LOW VOLTAGE, INSULATED HOUSING (SHIPBOARD USE), GENERAL SPECIFICATION FOR

ICS
CCS
K40
发布
2006-09-19
实施