L15 敏感元器件及传感器 标准查询与下载



共找到 409 条与 敏感元器件及传感器 相关的标准,共 28

Certain plastic surface-mount components are subject to permanent damage due to moistureinduced failures encountered during high-temperature surface-mount processing unless appropriate precautions are observed.

Symbol and Labels for Moisture-Sensitive Devices

ICS
CCS
L15
发布
1999-05-01
实施

This notice should be filed in front of MS244824 dated 22 April 1958

TRANSMITTER, TEMPERATURE, ELECTRICAL RESISTANCE, ARMORED, BAYONET LOCKING TYPE, (50 DEG. C TO 300 DEG. C)

ICS
CCS
L15
发布
1999-03-29
实施

This notice should be filed in front of MS27188, dated 1 February 1962. MS27188 is inactive for new design and is no longer used, except for replacement purposes.

PROBE, TOTAL TEMPERATURE, DEICEABLE

ICS
CCS
L15
发布
1999-03-26
实施

Semiconductor Manufacturers - from wafer electrical probe through shipment of finished devices except for in-process operations when all leads are shorted together.

Requirements for Handling Electrostatic-Discharge-Sensitive (ESDS) Devices Replaced JEDEC JESD42

ICS
CCS
L15
发布
1999
实施

1.1 This specification covers requirements for high-temperature electrical insulating tape consisting of glass cloth coated on one side with a pressure-sensitive adhesive.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.

Standard Specification for High-Temperature Glass Cloth Pressure-Sensitive Electrical Insulating Tape

ICS
29.035.20 (Plastic and rubber insulating materials
CCS
L15
发布
1999
实施

1.1 These test methods cover procedures for testing pressure-sensitive adhesive-coated tapes to be used as electrical insulation and are classified as follows: 1.1.1 Class 1 -Non-elastomeric backings made from materials such as: Paper, flat or creped, Fabric, uncoated or coated, Cellulose ester films, Polyethylene terephthalate (polyester) films, Fluorocarbon polymer films, Composite filament films, Polyamide films, Polyimide films, and Combinations thereof. 1.1.2 Class 2 -Elastomeric backings that are characterized by both high stretch and substantial recovery made from materials such as: Vinyl chloride and co-polymers, Vinylidene chloride and co-polymers, and Polyethylene and co-polymers. Note 1-Laminates of Class 1 and Class 2 backings should be tested according to Class 1 test methods. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards see Section 3. 1.3 The procedures appear in the sections indicated: Paper, flat or creped, Fabric, uncoated or coated, Cellulose ester films, Polyethylene terephthalate (polyester) films, Fluorocarbon polymer films, Composite filament films, Polyamide films, Polyimide films, and Combinations thereof. 1.4 The values stated in inch-pound units are the standard, unless otherwise noted. If a value for measurement is followed by a value in SI units in parentheses, the second value may only be approximate. The first stated value is the requirement.

Standard Test Method for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications

ICS
29.035.20 (Plastic and rubber insulating materials
CCS
L15
发布
1999
实施

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 233 : heat-shrinkable fluoroelastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 212 : heat-shrinkable polyolefin sleeving, flame retarded, shrink ratio 2:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 272 : heat-shrinkable elastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1, thin wall.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 228 : heat-shrinkable semi-rigid polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 271 : heat-shrinkable elastomer sleeving, flame retarded, fluid resistant, shrink ratio 2:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 218 : heat-shrinkable polyolefin sleeving, not flame retarded, shrink ratio 3:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Flexible insulating sleeving. Part 3 : specifications for individual types of sleeving. Sheet 217 : heat-shrinkable polyolefin sleeving, flame retarded, shrink ratio 3:1.

ICS
29.035.20
CCS
L15
发布
1998-12-01
实施
1998-12-05

Directly heated negative temperature coefficient thermistors

ICS
31.040.30
CCS
L15
发布
1998-11-20
实施

This part of ISO 16063 describes methods for the calibration of vibration and shock transducers. It also includes methods for the measurement of characteristics in addition to the sensitivity. One primary calibration method has been selected as the preferred method (see 5.2.1). Comparison calibration methods for vibration and shock are also described (see 5.3). More detailed descriptions are given in parts 1 to 23 of ISO 5347 (see references [1] to [22]). This part of ISO 16063 is applicable to continuous-reading rectilinear acceleration, velocity and displacement transducers and recommends a preferred method which has proved to give reliable and reproducible results. It is not applicable to methods for the calibration of rotational transducers.

Methods for the calibration of vibration and shock transducers - Part 1: Basic concepts

ICS
01.040.17;17.160
CCS
L15
发布
1998-10
实施

This notice should be filed in front of MlL-E-55199A, dated 18 September 1963.

ELECTRO-ACOUSTICAL TRANSDUCER EQUIPMENTS

ICS
CCS
L15
发布
1998-09-03
实施

This specification covers an ultrasonic motion signal transceiver and an ultrasonic motion signal processor which combine toform an ultrasonic motion sensor, designed to detect the motion of an intruder inside a protected space.

SENSOR GROUP, ULTRASONIC MOTION: TRANSCEIVER RT-1161/FSS-9 (V) AND PROCESSOR MX-9444/FSS-9 (V) [Use In Lieu Of: ARMY MIL-S-0052872 C NOTICE 1]

ICS
CCS
L15
发布
1998-07-17
实施

This test provides a means for determining the strength of the bond between a gold ball bond on a die bonding surface or an aluminum wedge or stitch bond on a package bonding surface, and may be performed on pre-encapsulation or postencapsulation parts. This measure of bond strength is extremely important in determining two features

Test Method B116 Wire Bond Shear Test

ICS
CCS
L15
发布
1998-07-01
实施

Calibration of electromagnetic field sensors and probes, excluding antennas, from 9 kHz to 40 GHz; Corrections

ICS
17.220.01
CCS
L15
发布
1998-05
实施

UL Standard for Safety Thermistor-Type Devices First Edition; Reprint with Revisions Through and Including 08/30/2002

ICS
31.040.30
CCS
L15
发布
1998-04-03
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号