P42 建筑给水、排水工程 标准查询与下载



共找到 260 条与 建筑给水、排水工程 相关的标准,共 18

This European Standard applies to electrolytic dosing systems for conditioning water intended for human consumption inside buildings and based on dissolution of aluminium anodes (with imposed DC current). It specifies constructional (but not dimensional) and operational requirements. It describes relevant methods for testing performance and safety. It only concerns units which are permanently connected to the mains supply.

Water conditioning equipment inside buildings - Electrolytic treatment systems with aluminium anodes - Requirements for performance and safety, testing; German version EN 14095:2003

ICS
13.060.20;91.140.60
CCS
P42
发布
2004-03
实施

Water conditioning equipment inside buildings - Electrolytic treatment with aluminium anodes - Requirements for performance, safety and testing

ICS
13.060.20;91.140.60
CCS
P42
发布
2004-01-12
实施
2004-01-12

Include language in requiring a manufacturer to specify who is authorized to install their treatment system.

Residential Wastewater Treatment Systems

ICS
91.140.80
CCS
P42
发布
2004
实施

lnclude language that the owner manuals will be added to the final report; detailed dimensional drawings representative of what was tested in the final report and pounds of BOD in influent and

Residential Wastewater Treatment Systems

ICS
91.140.80
CCS
P42
发布
2004
实施

Change CBOD5 to BOD5 in the influent water characteristics.

Residential Wastewater Treatment Systems

ICS
CCS
P42
发布
2004
实施

This standard specifies test methods for gullies for buildings according to EN 1253-1:2003 and access covers in accordance with EN 1253-4.

Gullies for buildings - Test methods

ICS
91.140.80
CCS
P42
发布
2003-12-19
实施
2003-12-19

This European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings.

Gullies for buildings - Gullies with light liquids closure

ICS
91.140.80
CCS
P42
发布
2003-11-18
实施
2003-11-18

Technical specification of polyethylene (PE),crosslinked polyethylene (PE-X) and polyethylene of raised temperature resistance (PE-RT) pipeline engineering for water supply in building

ICS
CCS
P42
发布
2003-11-14
实施
2004-01-01

本标准规定了以聚乙烯为主要原材料,子L网钢带为增强骨架,经挤出复合成型的孔网钢樽聚乙烯复 合管(以下简称复合管〉的要求、试验方法、检验规则、标志、包装、运输、贮存。 本标准适用温度 40℃ 以下给排水用管蒜工业用管也可选用。

Polyethylene(PE) composite pipes with porous steel strip for water supply

ICS
91.140.60
CCS
P42
发布
2003-06-03
实施
2003-10-01

Fauceting cast iron pipes and fittings with flexible joint for building drainage

ICS
91.140.80
CCS
P42
发布
2003-03-17
实施
2003-10-01

This Part 3 of EN 13566, read in conjunction with EN 13566-1:2002, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of non-pressure drainage and sewerage networks. It covers pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U). It is applicable to the plastic lining system only. It does not cover the requirements for the existing pipeline.

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Lining with close fit pipes

ICS
83.140.30;93.030
CCS
P42
发布
2003-02-04
实施
2003-02-04

This Part 4 of EN 13566, in conjunction with Part 1, specifies requirements and test methods for cured-in-place pipes and fittings used for renovation of underground non-pressure drainage and sewerage networks. It covers the use of various thermosetting resin systems in combination with compatible fibrous carrier materials and other process-related plastics components as defined in 4.1.

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Lining with cured-in-place pipes

ICS
83.140.30;93.030
CCS
P42
发布
2003-02-04
实施
2003-02-04

This standard specifies the requirements and test methods for plastics piping systems used for renovation of underground non-pressure drainage and sewerage networks which are operated as gravity systems and subject to a maximum surcharge pressure of 0,5 bar. It is applicable to pipes and fittings as manufactured as well as to the installed plastics lining system; it does not cover the existing pipeline or any annular filler. This Part of EN 13566 deals with the general requirements common to all relevant renovation techniques as defined in 3.1.2.

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - General

ICS
83.140.30;93.030
CCS
P42
发布
2003-02-04
实施
2003-02-04

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Lining with cured-in-place pipes

ICS
93.030
CCS
P42
发布
2003-02-04
实施
2003-02-04

Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - General

ICS
93.030
CCS
P42
发布
2003-02-04
实施
2003-02-04

This European Standard specifies the field of application, the dimensional, the physico-chemical, the design, the hydraulic, the mechanical, and the acoustic characteristics of controllable backflow preventer with reduced pressure zone Family B Type A. This standard covers controllable backflow preventers of Family B Type A, with reduced pressure zones, intended to prevent backflow by backsiphoning or backpressure of water into the potable water distribution system whenever the pressure of the latter is lower than the system located downstream. It is applicable to controllable backflow preventers in denominations DN 8 up to DN 250. It covers controllable backflow preventers of PN 10 that are capable of working without modification or adjustment: — at any pressure up to 1 MPa (10 bar); — with any pressure variation up to 1 MPa (10 bar); — in permanent duty at a limited temperature of 65 ℃ and 90 ℃ for 1 h maximum. It specifies also the test methods and requirements for verifying their characteristics, the marking and the presentation at delivery.

Devices to prevent pollution by backflow of potable water - Controllable backflow preventer with reduced pressure zone - Family B. Type A

ICS
13.060.20;91.140.60
CCS
P42
发布
2003-01-30
实施
2003-01-30

This European Standard specifies the field of application, the dimensional, the physico-chemical, the design, the hydraulic, the mechanical, and the acoustic characteristics of controllable backflow preventer with reduced pressure zone Family B Type A. This standard covers controllable backflow preventers of Family B Type A, with reduced pressure zones, intended to prevent backflow by backsiphoning or backpressure of water into the potable water distribution system whenever the pressure of the latter is lower than the system located downstream. It is applicable to controllable backflow preventers in denominations DN 8 up to DN 250. It covers controllable backflow preventers of PN 10 that are capable of working without modification or adjustment: — at any pressure up to 1 MPa (10 bar); — with any pressure variation up to 1 MPa (10 bar); — in permanent duty at a limited temperature of 65 ℃ and 90 ℃ for 1 h maximum. It specifies also the test methods and requirements for verifying their characteristics, the marking and the presentation at delivery.

Devices to prevent pollution by backflow of potable water - Controllable backflow preventer with reduced pressure zone - Family B. Type A

ICS
13.060.20;91.140.60
CCS
P42
发布
2003-01-30
实施
2003-01-30

Technicalspecification for chlorinated poly (vinyl choride)pipline engineering of building water supply

ICS
91.140.60
CCS
P42
发布
2002-12-01
实施
2002-12-01

本规程适用于立管采用硬聚氯乙烯(PVC-U)内螺旋管材及配套连接管件的连续排放温度不大于40℃、瞬时排放温度不大于80℃的生活排水管道工程的设计、施工及验收。

Technical specification of PVC-U innerspiral rib pipe for building drainage

ICS
91.140.80
CCS
P42
发布
2002-09-01
实施
2002-09-01

Technical specification of PVC-U innerspiral rib pipe for building drainage

ICS
91.140.80
CCS
P42
发布
2002-09-01
实施
2002-09-01