Q76 建筑暖通、空调器材设备 标准查询与下载



共找到 563 条与 建筑暖通、空调器材设备 相关的标准,共 38

Ventilation for buildings - Air handling units - Rating and performance for units, components and sections; German version EN 13053:2006+A1:2011

ICS
91.140.30
CCS
Q76
发布
2012-02-01
实施
2012-02-01

Refrigerating systems and heat pumps - Qualification of tightness of components and joints; German version EN 16084:2011, Corrigendum to DIN EN 16084:2011-07

ICS
27.080;27.200
CCS
Q76
发布
2012-02
实施

This proposal provides clarification of test duct air flow.

Standard for Safety for Air Filter Units (Proposal dated 10-07-11)

ICS
13.040.40
CCS
Q76
发布
2012-01-01
实施

This is a revision of the current published ANSI/ASHRAE Standard 127-2007. This standard provides a uniform set of requirements for rating computer and data processing room unitary (CDPR) air conditioners. This standard does not apply to the rating of individual assemblies, such as condensing units or direct expansion fan-coiled units, for separate use.

Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Provides a means of accurately measuring the refrigerant mass flow capacity of solenoid valves. The flow capacity may be expressed in terms of refrigerating effect with various refrigerants by performing simple thermodynamic computations.

Methods of Testing Capacity of Refrigerant Solenoid Valves

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

The proposed changes are intended to clarify and coordinate requirements of the Standard with the FGI Guidelines for Design and Construction of Health Care Facilities.

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

This addendum proposes that the airflow requirements of Section 7.4.1 apply to both Caesarian delivery rooms and Operating/surgical cystoscopic rooms. Both of these spaces are typically already programmed as Class B surgeries. This addendum also proposes additional entries for Table 7-1.

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

This recirculation proposal includes revisions to 7.27 and Section 9 for Test Duct Air Flow.

Standard for Safety for Air Filter Units 9 (Proposal bulletin dated 12/16/11)

ICS
13.040.40
CCS
Q76
发布
2012-01-01
实施

This addendum proposes clarifying requirements for the use of fully ducted return systems by recognizing that some spaces requiring a negative pressure relationship with the adjacent space require a fully ducted exhaust system rather than a return air system. This modification is made in Section 6.7.1, where the standard already has requirements for ducted return systems for spaces with a required pressure relationship. This addendum also proposes adding four additional spaces to meet the requirement for being fully ducted.

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

The following changes in requirements to the Standard for Safety for Grease Filters for Exhaust Ducts, UL 1046, are being proposed: (1) Clarification of acceptance requirements for flame exposure test.

Standard for Safety for Grease Filters for Exhaust Ducts

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

The changes included in this proposed addendum are primarily intended to coordinate with the 2010 Guidelines for the Design and Construction of Health Care Facilities. Specific changes include: - the addition of two new definitions: ôabsorption distanceö and ôessential accessoriesö; - a change to Section 5 to clarify that ôequipmentö refers to non-HVAC equipment, new 6.4.4 to minimize air leakage around filters; - new 6.7.3 on smoke barriers; - new 6.7.4 on smoke and fire dampers; - new 6.7.5 on duct penetrations; - new 6.8 on psychiatric patient areas; and - new 7.5.2 to improve infection control in spaces where patients are likely to be coughing.

Ventilation of Health Care Facilities

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

ICS
91.140.30
CCS
Q76
发布
2012-01-01
实施

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods; German version EN 14511-3:2011

ICS
91.140.30
CCS
Q76
发布
2012-01
实施

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions; German version EN 14511-1:2011

ICS
01.040.91;91.140.30
CCS
Q76
发布
2012-01
实施

Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions; German version EN 14511-2:2011

ICS
91.140.30
CCS
Q76
发布
2012-01
实施