共找到 97 条与 牵引变电 相关的标准,共 7 页
Railway applications - Fixed installations - Electronic power converters for substations; German version EN 50328:2003
Railway applications - Fixed installations - Harmonisation of the rated values for converter groups and tests on converter groups; German version EN 50327:2003
This European Standard covers general purpose standard dimensioned triphased induction motors for 50 Hz with rated voltages not exceeding 690 V for industrial purposes having dimensions selected from IEC 60072-1 in the range : Frame numbers - shaft-heights: 56 mm to 315 mm Flange numbers - pitch circle diameter of flange: 65 mm to 740 mm It gives Tables of fixing dimensions, shaft extension dimensions and output powers.#,,#
General purpose three-phase induction motors having standard dimensions and outputs - Frame numbers 56 to 315 and flange numbers 65 to 740; German version EN 50347:2001
This European Standard covers specific characteristics of traction transformers as defined in 1.3.1, used in traction substation or along the track for the supply of power to a.c. and d.c. traction systems or to provide power to auxiliary services. Traction transformers are either - single-phase traction transformers, - single-, three- or poly-phase rectifier-transformers or converter/inverter-transformers for d.c. or a.c. contact line, - single phase auto-transformers for traction power supply, - single- or three-phase auxiliary transformers at traction supply voltage. Transformers feeding a.c. contact lines are covered by EN 60076. Dry-type transformers are covered by HD 464. These standards are valid with the additional requirements given in this document. For transformers feeding contact lines through static converters EN 61378-1 may assist, but modified or additional requirements are given in this document. NOTE Transformers mounted on-board traction vehicles are covered by EN 60310 and are excluded from the scope of this document. Electromagnetic compatibility is ruled by EN 60076-1 which states that a transformer may be considered a passive element in this respect. Some accessories however are subject to EMC requirements and shall comply with EN 50121-5.
Railway applications. Fixed installations. Traction transformers
Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components; Rules for d.c. circuit-breakers (IEC 60077-3:2001); German version EN 60077-3:2002
Prescribes the maximum dimensional requirements of each battery tray for a specific number of cells and battery capacity or performance rating.
Standard for Rail Transit Vehicle Battery Physical Interface
Railway applications - Rolling stock - Combined testing - Part 2 : chopper-fed direct current traction motors and their control.
Railway applications - Electric equipment for rolling stock - Part 1 : general service conditions and general rules.
Railway applications - Electric equipment for rolling stock - Part 2 : electrotechnical components - General rules.
This European Standard specifies the functional requirements for output and accuracy of measurements of the dynamic interaction between pantograph and overhead contact line.
Railway applications. Current collection systems. Requirements for and validation of measurements of the dynamic interaction between pantograph and overhead contact line
Code for design auxiliary power supply in traction substation on railway
Railway applications - Rotating electrical machines for rail and road vehicles - Part 2: Electronic converter-fed alternating current motors (IEC 60349-2:1993, modified); German version EN 60349-2:2001
Railway applications - Rolling stock equipment - Capacitors for power electronics.
Railway applications - Traction transformers and inductors on rolling stock.
This document defines the general assembly characteristics which are to be applied to pantographs, to enable current collection from the overhead line system. It also defines the tests the pantographs have to perform, excluding insulators. This standard does not apply to pantograph dielectric tests, which are to be performed on the pantograph installed on the vehicle roof. This standard does not apply to pantographs used on isolated metros and light rail systems : these pantographs are considered in EN 50206-2.
Railway applications. Rolling stock. Pantographs: Characteristics and tests. Part 1: Pantographs for main line vehicles
Aluminum-clad steel-cored aluminum stranded wire for electrified railway
Technical specifications for low-voltage AC distribution panels (cabinets) for electrified railways
DC power supply device for medium-rate nickel-cadmium battery for electrified railway
本标准规定了电气化铁道牵引供电系统的技术要求、试验、检验及标志、包装、运输、贮存等。 本标准适用于电气化铁道牵引供电运动系统。
Technical specification for electrified railway traction power supply telecontrol system
27.5kV single-phase copper core XLPE insulated cable for electrified railway
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号