首页 > 产品展示 >  > MPC-102自动微量倾浊点试验仪

MPC-102自动微量倾浊点试验仪

参考报价: 面议 型号: MPC-102
品牌: 暂无 产地: 暂无
关注度: 161 信息完整度:
样本: 典型用户: 暂无
咨询留言 在线咨询

400-6699-1171000




自动微量倾浊点测试仪
MPC-102
New Standard ASTM D6749
No Methanol
新标准ASTM D6749,无甲醛

MPC-102 series has been designed for automatic determination of Pour Point (PP) and Cloud Point (CP) with small specimen size and shorter test cycle time while securing better test precision than the conventional manual methods’. PP measurement is made utilizing a new ASTM test method, namely “Air Pressure Method”(*1), which yields eventually no bias against the conventional test method, repeatability/reproducibility of 1℃/2℃ and 2-3 times faster determinations. The epoc-making high accuracy justifies PP determination at 1℃ intervals, which can help increasing the yields in the process. The CP/PP mode executes a CP determination and then PP determination consecutively, which further improves the test throughput in the lab. In addition to liquid-cooled model MPC-102L, air-cooled model MPC-102A is available. Multiple-tests versions with 6 test heads and 3 test heads are also available for higher volume tests.
MPC-102系列自动微量倾浊点测试仪,采用微量法测试样品的倾点,取样量少,测定过程由计算机自动完成,无需人工干预,测定速度快而结果准确。测定样品的同时可同时测定样品的浊点。仪器进行倾点测试时,没有采用传统的“倾斜法”,而采用了新的标准ASTM D6749 “空气加压法”。测试结果与ISO3016和ASTM D97是所描述的倾斜法完全一致。样品的测试间隔为1℃/2℃,并同时连续测试2-3次,测试结果具有更好的重复性和再现性。
MPC系列有多种型号可选择。MPC-102L是液冷型,MPC-102A是风冷型。MPC-302适用于3样品同时测试,MPC-602用于6样品同时测试。
*1:ASTM D6749 on “Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method)” ASTM D6749《石油产品倾点测定法(自动空气加压法)》

HIGH PRECISION POUR POINT DETERMINATION: 高精度的倾点测定
The typical repeatability and reproducibility are 1℃ and 2℃ respectively, when PP is determined at 1℃ intervals.(*2) This high precision attributes to the patented Air Pressure method, in which the disturbance to the formation of wax crystal structure through the test process is kept at a minimal and consistent level. “气压法”可有效避免降温过程中,样品的蜡状析出和冰晶体对结果的干扰,按1℃间隔测试样品,精度更高。
*2:Precision information is for general samples such as diesel fuels, base oils and finished lube oils. 柴油,基础油和调和润滑油。

POUR POINT AT 1℃ TESTING INTERVALS:
With this high precision, PP can be determined at 1℃ intervals for more precise process control, and therefore a considerable savings in the procss can be realized.仪器可按1℃间隔测试样品,测试精度大于试验标准测试规定,可以保证试验结果的精度更高。(重复性:倾点±1℃ 或3℃(仪器可按传统方式3℃间隔测试);浊点:±1℃)

EASY AND QUICK PP/CP DETERMINATION:
Just set up a sample, select a test mode and then press the START key. The sample is cooled at the steepest possible rate without affecting the formation/growth of wax crystal, which has been known to be a critical factor for PP/CP determination. The test cycle time is typically 1/3 to 1/2 of that of the conventional tilting method’s.(*3) 选好样品后,输入测试参数,预期的倾/浊点数据,按下“开始”键。仪器即可按标准自动进行测试,并输出结果。
相较于传统测试方式,“气压法”的效率更高,一般只要传统方式的1/3 或 1/2的时间,就可以完成测试。可在短时间内进行多组测试。
*3:When a diesel fuel oil with PP of –32.5℃ is tested, the Air Pressure method took 45 minutes while the conventional tilting method took 140 minutes. Note that the Japan Industrial Standard defines PP in 2.5℃ increments 柴油的倾点一般在–32.5℃左右,按传统方法测试,每隔2.5℃测试一次,一个测试过程需要140分钟,而应用“气压法”的测试过程只要45分钟,效率更高。

EASY SAMPLE HANDLING: 采样少,易操作
Since the required sample volume is a mere 4.5mL and the sample cup is a test-tube type removable jar, the sample handling is extremely easy.样品仅需求4.5毫升,玻璃小型样品杯是一个可取放的瓶状试管,操作极其简单。


COMPACT DESIGN &ENERGY EFFICIENT:
Use of Peltier Cells for sample cooling/heating made this “mini” tester not only compact in design but energy efficient. Depending on the temperature range, either air, tap water or small chiller with anti-freeze suffices the cooling requirement. No methanol is required. 仪器整体为台式结构,体积小,占地少,仪器本体内置半导体制冷源及加热装置。使用小型样品杯,取样量少,制冷迅速,效率很高。配合不同的冷浴介质,用于不同的测量范围。无需甲醛。

TANAKA Mini Pour/Cloud Point Tester, series MPC-102

SPECIFICATIONS:
TYPE:
Mini Pour Point(PP) and Cloud Point(CP) tester with sequential CP and PP measuring capability.
应用“气压法”测试样品倾点(PP),浊点(CP),或样品的浊点(CP)+倾点(PP)的连续测定
Sample cooling and pre-heating by TED. 特有的半导体制冷/加热设计。

TEST STANDARDS:适用标准
ASTM D6749/D97, ISO 3016 (PP), (倾点)
ASTM D2500, ISO 3015 (CP) (浊点)

SPECIMEN VOLUME(样品量): 4.5ml

MEASURING RANGE: (typical*) 测试范围
1.MPC-102L(Liquid cooled model):(液冷型)
+51℃ to - 40℃ with tap water of 20℃ (直接外接循环水冷,水温约在20℃)
+51℃ to - 65℃ with cooling liquid of -35℃ (外接循环制冷源,介质温度约在零下35℃)

2.MPC-102A(Air cooled model): (风冷型)
+51℃ to -30℃ (in 25℃ ambient) (环境温度在25℃左右)

*:Sample viscosity, etc. affects on lowest temperature of the measuring range.
样品本身的低温运动粘度的性质,限制了试验所需要zei低的测试温度。

MEASUREMENT MODES: 测试模式
Selectable from various modes.可选择多种测试模式
1.CP mode (0.1 or 1.0 ℃, selectable) 浊点测试模式(每隔0.1 或 1.0℃测试)

2.PP modes: Programmed by the user. Programmable倾点测试模式,按用户要求组合
parameters are: 需要先选择油品种类,再选择测试温度。
*Amount of applied air pressure for PP detection, to accommodate different sample types: L(low) for diesel fuels, H(high) for lube oils, VH(very high) and UH (ultra high) for residual fuels and similar samples. 按油品种类(L-柴油;H-润滑油;VH或 UH-重油/渣油)
*Testing intervals: 1.0℃, 2.5℃, or 3.0℃ 按温度每隔1.0℃, 2.5℃, 或 3.0℃测试
(In total, 4x3=12 modes for PP.) 以上总计12种组合倾点测试模式

3.CP/PP modes: 浊点+倾点连续测试 (重复测试)
CP is determined and then PP. PP detection is programmable by the user with the same parameters as PP modes’. (12 modes in total.) 到检测出倾点后,样品被自动加热至与室温一致,再次连续测试样品,或再次按不同的模式测试样品,尤其适用于科研场合。

SAMPLE AUTOMATIC PRE-HEATING:样品自动加热
Automatic preheating at either +45℃ or EPP+10℃. (EPP=Expected Pour Point)
按试验方法对样品预热步骤的要求,仪器也包括了样品预热的功能。每次测试时,样品会按要求被预热到(45℃)或(预期倾点+10℃)

DISPLAY: (显示)
Test parameters, EPP, bath temperature, sample temperature, PP, and CP displayed on VFD. Temperatures displayed in 0.1℃ increments.
VFD荧光屏,清晰显示试验参数,冷浴温度,样品温度,倾点,浊点,预期倾点等内容。
温度显示精度0.1℃。

EPP SETTING: 预期倾点设定
EPP(Expected Pour Point) needs to be set prior to test Starts. 测试开始时需要输入预期倾点

SPECIMEN CUP: (样品杯)
Cylindrical glass test jar with 4.5ml sample volume.
石英玻璃的小型样品杯,每次试验只需要4.5ml的样品

SENSORS: 传感器
Compound type sensor assembly for PP and CP. 同一仪器既可以检测倾点,也可以检测浊点
PP detected by air pressure method(patented). (专利设计的)气压传感器变化检测倾点
CP detected photo-electrically.光电传感器检测浊点
PT100 temp. sensors. PT-100铂电阻检测温度

SAMPLE COOLING RATE: 降温速率
As standard, 4℃/min. till EPP+40℃, and 1℃/min. thereafter. Cooling profile is programmable.
按标准规定:在预期倾点+40℃以前,降温速率4℃/min;在此以后,降温速率1℃/min。
用户也可以自行设定特殊的降温曲线,便于科研应用。

SAFETY SHUTDOWN: 安全保护
As hot side of TED reaches 60℃ while preheating, warning buzzer beeps and heating stops.
半导体热面温度达到(60℃),超过限定时 ,仪器报警提示,并且自动停机

DATA OUTPUT: 数据输出
RS-232C 1 channel (for PC or Optional Printer)
标准RS-232C接口,1(可用于计算机联机控制或外接打印机输出)

DATA STRAGE 记录保存
Last 50 test data are stored in RAM 记录zei后50次试验结果,即使掉电,数据也不会丢失。

POWER REQUIREMENTS: (电源需求)
100, 120, 220, or 240VAC 0.5kW

DIMENSIONS AND WEIGHT: (体积和重量)
230mmWx480mmDx385mmH, 20kg

ORDERING INFORMATION:

STANDARD ACCESSORIES: (标准附件)
1.Specimen Cup with Reflex Seal 样品杯(带反光贴片)
5 pcs

2.Spare Pressure Conducting Tube 导压软管
2 pcs

3. AC Power Cord, 3.0m (2.5m (>AC200V) 电源线
1 pc

4.Connecting Cables(set of 2) 连接线
1 set

5.Hose and clamps(MPC-102L) 软管和夹具(液冷型)
1 set

6.Dripping Plate(MPC-102L)防滴盘(液冷型)
1 pc

7.Instruction manual使用说明书
1 copy


OPTIONAL ACCESSORIES: (选购件1)
·Water Regulator with Pressure Gauge (MPC-102L, for Connecting Tap Water)
循环泵组件 (MPC-102L,直接外接水冷专用)

·Chillers for -60℃ of Measurement: TANAKA TCU-40B (MPC-102L): or Neslab RTE-740(*1) or Julabo FP40-MC(*2) *1:Made in USA. *2:Made in Germany
试验温度要求-60℃(零下60℃)需要外接循环制冷源,推荐以下型号:
TANAKA TCU-40B(日本田中制)或RTE-740(美国制)或Julabo FP40-MC(德国制)

·Chiller for -45℃ of Measurement: Neslab RTE-7(*1)
试验温度要求-45℃(零下45℃)需要外接循环制冷源,推荐以下型号:Neslab RTE-7(美国制)

·Printer, BS2-80TS (w/ AC Adapter and Connecting Cable) 打印机(带电源和连接线)

·Built-in Clock Board (内置时钟板)

SUGGESTED SPARES FOR 2 YEARS: (选购件2,2年维护)
1.Specimen Cup with Reflex Seal样品杯(带反光贴片)
20 pcs

2.Reflex Seal(反光贴片)
30 pcs

3.Pressure Conducting Tube导压软管
5 pcs

4.O-Ring set (G-35 and P-8) O型圈(G-35 +P-8)
2 sets