These requirements cover pressure regulators for use with LP-Gas equipment. Regulators covered by these requirements are intended for use in non-refrigerated systems in accordance with the following standards: a) Liquefied Petroleum Gas Code@ (National Fire Codes@ Vol. 2) NFPA 58; b) National Fuel Gas Code ( IAS/A.G.A. Z223.1)@ NFPA 54; c) Outdoor Cooking Gas Appliances@ IAS/A.G.A. Z21.58; and d) Standard on Recreational Vehicles (RVIAA119.2) (National Fire Codes@ Vol. 7)@ NFPA 501C. These requirements do not cover: a) Compressed gas regulators; b) Gas appliance pressure regulators; c) Regulators for use in chemical@ petroleum@ or utility power plants; pipeline or marine terminals; or related storage facilities at such plants or terminals; d) Combination gas control valves for gas appliances; e) Regulators for use in oxygen-fuel@ gas-welding@ and cutting operations; and f) Regulators for use in engine fuel (automotive and/or marine) applications. The requirements for (a) ?C (e) are covered in the Standard for Compressed Gas Regulators@ UL 252@ and in the Standard for Gas Appliance Pressure Regulators@ IAS/A.G.A. Z21.18@ and in the Standard for Combination Gas Controls for Gas Appliances@ IAS/A.G.A. Z21.78@ respectively. The assigning of flow ratings to regulators is not within the scope of these requirements@ and observations of flow values are required to ascertain stability characteristics within the manufacturer's rated capacity. These requirements include tests to verify outlet pressure stability characteristics within the manufacturer's rated capacity. The manufacturer is to submit this data prior to the investigation of the device. See the Flow Test@ 25.1.1 and 25.1.2@ regarding the outlet pressure instability definition.
144-2012由UL - UL 发布于 2012-05-25,并于 2014-11-07 实施。
非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 144-2012 前三页,或者稍后再访问。
点击下载后,生成下载文件时间比较长,请耐心等待......
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号