N323-1978

Radiation Protection Instrumentation Test and Calibration


N323-1978 发布历史

This standard establishes calibration methods for?portable radiation protection instruments used for detection and measurement of levels of ionizing radiation fields or levels of radioactive surface contamination. For purposes of this standard@ portable radiation protection instruments are those which are carried by hand to a specific facility or location for use. Although this standard is specific to portable radiation protection instrumentation@ the basic calibration principles may be applicable to radiation detection instrumentation in general.Included within the scope of this standard are conditions@ equipment@ and techniques for calibration as well as the degree of precision and accuracy required. Alpha@ beta@ photon@ and neutron radiations are considered. Passive integrating dosimetric devices such as film@ thermoluminescent@ and chemical dosimeters are outside the scope of this standard@ but the basic principles and intent may apply. In cases where integrating capability is included along with rate measurement or detection@ this standard shall apply.Throughout these criteria@ four verbs have been used to indicate the degree of rigor intended by the specific criterion. ??Shall?? and ??will?? indicate a minimum criterion that must be met@ while ??should?? and ??would?? indicate a criterion that is recommended as good practice and is to be applied when practical.

N323-1978由IEEE - The Institute of Electrical and Electronics Engineers@ Inc. 发布于 1978-01-01,并于 1978-01-01 实施。

N323-1978的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 N323-1978 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
N323-1978
发布日期
1978年01月01日
实施日期
1978年01月01日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
引用标准
21
适用范围
This standard establishes calibration methods for?portable radiation protection instruments used for detection and measurement of levels of ionizing radiation fields or levels of radioactive surface contamination. For purposes of this standard@ portable radiation protection instruments are those which are carried by hand to a specific facility or location for use. Although this standard is specific to portable radiation protection instrumentation@ the basic calibration principles may be applicable to radiation detection instrumentation in general.Included within the scope of this standard are conditions@ equipment@ and techniques for calibration as well as the degree of precision and accuracy required. Alpha@ beta@ photon@ and neutron radiations are considered. Passive integrating dosimetric devices such as film@ thermoluminescent@ and chemical dosimeters are outside the scope of this standard@ but the basic principles and intent may apply. In cases where integrating capability is included along with rate measurement or detection@ this standard shall apply.Throughout these criteria@ four verbs have been used to indicate the degree of rigor intended by the specific criterion. ??Shall?? and ??will?? indicate a minimum criterion that must be met@ while ??should?? and ??would?? indicate a criterion that is recommended as good practice and is to be applied when practical.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号