61010-2-010 BULLETIN-2014

UL Standard for Safety Requirements for Electrical Equipment for Measurement@ Control@ and Laboratory Use – Part 2-010: Particular Requirements for Laboratory Equipment for the Heating of Materials (COMMENTS DUE: DECEMBER 22@ 2014)


哪些标准引用了61010-2-010 BULLETIN-2014

 

找不到引用61010-2-010 BULLETIN-2014 的标准

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 61010-2-010 BULLETIN-2014 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
61010-2-010 BULLETIN-2014
发布日期
2014年11月07日
实施日期
2019年03月29日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
24
适用范围
Equipment included in scope This part of IEC 61010 specifies general safety requirements for electrical equipment intended for professional@ industrial process@ and educational use@ any of which may incorporate computing devices@ as defined in a) to d) below@ when used under the environmental conditions of 1.4. a) Electrical test and measurement equipment This is equipment which by electrical means tests@ measures@ indicates or records one or more electrical or non-electrical quantities@ also non-measuring equipment such as signal generators@ measurement standards@ power supplies@ transducers@ transmitters@ etc. NOTE All indicating and recording electrical measuring instruments (except those excluded in 1.1.2) fall within the scope of IEC 61010 unless they are panel meters designed only for building-in to other equipment. Built-in panel meters are considered to be components and only need to meet the relevant requirements of IEC 61010@ or other standards@ as part of the equipment into which they are built. b) Electrical control equipment This is equipment which controls one or more output quantities to specific values@ with each value determined by manual setting@ by local or remote programming@ or by one or more input variables. c) Electrical laboratory equipment This is equipment which measures@ indicates@ monitors or analyses substances@ or is used to prepare materials@ and includes in vitro diagnostic (IVD) equipment This equipment may also be used in areas other than laboratories@ for example self-test IVD equipment may be used in the home. d) Accessories intended for use with the above (for example@ sample handling equipment). 1.1.1DV.1 DE Modification of item (a) by adding the following: This Part 1 applies to test equipment integrated into manufacturing facilities intended for testing electronic devices@ including silicon wafers and other semiconductor devices. NOTE This equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application. Equipment excluded from scope This standard does not apply to equipment within the scope of a) IEC 60065 (Safety requirements for audio@ video and similar electronic apparatus); b) IEC 60204 (Controls for electrical machines); c) IEC 60335 (Safety of household and similar electrical appliances); d) IEC 60364 (Electrical installations of buildings); e) IEC 60439-1 (Low-voltage switchgear and controlgear assemblies); f) IEC 60521 (Class 0@5; 1 and 2 alternating current watthour meters); g) IEC 60601 (Medical electrical equipment); h) IEC 60950 (Safety of information technology equipment including electrical business equipment@ except as specified in 1.1.3); i) IEC 61558 (Power transformers@ power supply units and similar). Computing equipment This standard applies only to computers@ processors@ etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment. NOTE Computing devices and similar equipment within the scope of IEC 60950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However@ some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in this standard. If HAZARDS from moisture or liquids could affect equipment that conforms to IEC 60950 and is used with equipment which conforms with this standard@ the instructions for use should specify any additional precautions required. 1.1.3ADV DR Addition of the following referencing the National Electrical Code and the Canadian Electrical Code: This standard applies to equipment to be employed in accordance with ANSI/NFPA 70@ National Electrical Code? (NEC); designed to be installed in accordance with the Canadian Electrical Code (CEC)@ Part I@ CSA C22.1@ and CSA C22.2 No. 0; or designed to comply with both the NEC and CEC. Object Aspects included in scope The purpose of the requirements of this part 1 is to ensure that the design and methods of construction used provide adequate protection for the OPERATOR and the surrounding area against a) electric shock or burn (see clause 6); b) mechanical HAZARDS (see clauses 7 and 8); c) excessive temperature (see clauses 9 and 10); d) spread of fire from the equipment (see clause 9); e) effects of fluids and fluid pressure (see clause 11). f) effects of radiation@ including lasers sources@ sonic and ultrasonic pressure (see clause 12); g) liberated gases@ explosion and implosion (see clause 13). NOTE Attention is drawn to the existence of additional requirements which may be specified by national authorities responsible for the health and safety of labour forces. Aspects excluded from scope This standard does not cover a) reliable function@ performance or other properties of the equipment not related to safety; b) effectiveness of transport packaging; c) EMC requirements@ which are covered by IEC 61326; d) protective measures for explosive atmospheres (see IEC 60079); e) servicing (repair); f) protection of servicing (repair) personnel. NOTE Servicing personnel are expected to be reasonably careful in dealing with obvious HAZARDS@ but the design should protect against mishap by the use of warning labels@ shields for hazardous voltage TERMINALS@ segregation of low-voltage circuits from hazardous voltages@ etc. More important@ servicing personnel should be trained to recognize unexpected HAZARDS and to react accordingly. Verification This standard also specifies methods of verifying@ through inspection and type testing@ that the equipment meets the requirements of this standard. NOTE Requirements for ROUTINE TESTS are given in annex F. Environmental conditions Normal environmental conditions This standard applies to equipment designed to be safe at least under the following conditions: a) indoor use; b) altitude up to 2 000 m; c) temperature 5 ??to 40 ?? d) maximum relative humidity 80 % for temperatures up to 31 ??decreasing linearly to 50 % relative humidity at 40 ?? e) MAINS supply voltage fluctuations up to ??10 % of the nominal voltage; f) transient overvoltages typically present on the MAINS supply. NOTE The normal level of transient overvoltages is impulse withstand (overvoltage) category II of IEC 60364-4-443. g) applicable RATED POLLUTION degree. Extended environmental conditions This standard applies to equipment designed to be safe not only in the environmental conditions specified in 1.4.1@ but also in any of the following conditions for which the equipment is RATED by the manufacturer: a) outdoor use; b) altitude above 2 000 m; c) ambient temperatures below 5 ??or above 40 ?? d) relative humidity above the levels specified in 1.4.1; e) MAINS supply voltage fluctuations exceeding ??10 % of the nominal voltage. Equipment included in scope Replacement: This part of IEC 61010 specifies safety requirements for electrically powered laboratory equipment for the heating of materials@ where the heating of materials is one of the functions of the equipment. NOTE If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard@ it will also need to meet the requirements of those other part 2 standards. In particular@ if equipmen is intended to be used for IVD purposes@ it will need to meet the requirements of IEC 61010-2-101. Equipment excluded from scope Addition after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter@ and which is large enough for the OPERATOR to remain inside with the door or doors closed.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号