60079-26-2004
Matériel électrique pour atmosphères explosives gazeuses – Partie 26: Construction@ essais et marquage des matériels électriques de Groupe II utilisables en Zone 0 (Edition 1.0)

Electrical apparatus for explosive gas atmospheres – Part 26: Construction@ test and marking of Group II Zone 0 electrical apparatus (Edition 1.0)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60079-26-2004 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
60079-26-2004
发布日期
2004年03月01日
实施日期
2006年08月25日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
42
适用范围
This part of IEC 60079 specifies the particular requirements for construction@ test and marking for electrical apparatus of Group II intended for use in Zone 0 as defined in IEC 60079-10.This electrical apparatus@ within the operational parameters specified by the manufacturer@ ensures a very high level of protection that includes rare faults related to the apparatus or two faults occurring independently of each other.NOTE 1 A malfunction may result from a failure of the component parts of the electrical apparatus or from anticipated externally applied influences. Two independent malfunctions which may occur more frequently and which@ separately@ would not create an ignition hazard but which@ in combination@ could create a potential ignition hazard@ should be regarded as occurring together to form a rare fault.This electrical apparatus is intended for use in Zone 0 hazardous areas@ in which explosive gas atmospheres caused by mixtures of air and gases@ vapours or mists under normal atmospheric conditions are present continuously@ for long periods or frequently.This standard also applies to apparatus mounted across the boundary between Zone 0 and Zone 1.EXAMPLE: In the wall of a storage vessel.This standard also applies to apparatus installed outside Zone 0@ but electrically connected to apparatus inside Zone 0 (associated apparatus).This standard supplements the general requirements in IEC 60079-0 and the requirements of the standardized types of protection@ in accordance with the IEC 60079 series@ to adapt the level of safety provided by those standards to the very high level of risk in Zone 0.NOTE 2 In designing apparatus for operation in explosive gas atmospheres under conditions other than the atmospheric conditions given in IEC 60079-0@ this standard may be used as a guide. However@ additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection ??Flameproof enclosure?? (IEC 60079-1) and ??Intrinsic safety?? (IEC 60079-11) are applied.NOTE 3 The classification of hazardous areas in zones is defined in IEC 60079-10.NOTE 4 There may be other non-electrical sources of ignition (for example ultrasonic@ optical or ionizing radiation) that are not addressed by this standard; these should also be taken into consideration (see@ for example@ EN 1127-1).




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号