65-1956

Proposed Test Procedure for THERMAL EVALUATION of VENTILATED DRY-TYPE POWER and DISTRIBUTION TRANSFORMERS


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 65-1956 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
65-1956
发布日期
1956年11月01日
实施日期
2016年03月17日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
引用标准
16
适用范围
PREFACE For many years@ temperature limits for electric apparatus have been founded upon classification of insulating materials by broad general definitions based upon chemical composition1. Recently@ it has become apparent that this method no longer meets the needs of the industry and that a new approach is needed@ based upon functional tests.w?6'6 The latest revision of AIEE No. I1 recognizes this need by the following statement: The electrical insulation of equipment is made up of many different components@ selected to withstand the widely different electric@ mechanical and thermal stresses occurring in different parts of the structure. To assure satisfactory service life@ therefore@ insulation specifications need to be supported by service experience or life tests@ on the complete insulation system. Accelerated life tests are increasingly important as a means of evaluating the many new synthetic insulating materials that are available@ thus shortening the period of service experience required before they can be used with confidence. It is desirable that life tests on materials be supplemented by tests on complete insulation systems@ representative of the different types of equipment. It is contemplated that@ in the course of time@ Institute Test Codes will be developed@ giving procedures for such accelerated life tests@ and other methods of evaluating insulating materials and systems. Accordingly@ this test procedure is intended to establish methods for evaluating the insulating systems of ventilated dry-type power and distribution transformers. It is expected that test procedures covering other classes of transformers will be prepared from time to time as the lengthy but necessary study and trials are completed. During the preparation of this test procedure@ members of the subgroup built and tested more than fifty transformer models in accordance with the recommended methods. The results demonstrated that the methods are workable@ even though there were a few details on which further work will be necessary before final decisions can be made. The test procedure@ therefore@ is offered for trial use in order to obtain wider distribution and to encourage discussion@ criticism@ and trial by others.

谁引用了65-1956 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号