NESC-2012

National Electrical Safety Code(R)


NESC-2012 发布历史

A. Covered See Figure 011-1. The NESC covers: 1. Supply and communication facilities (including metering) and associated work practices employed by a public or private electric supply@ communications@ railway@ trolley@ street and area lighting@ traffic signal (or other signal)@ irrigation district or other community owned utility@ or a similar utility in the exercise of its function as a utility. 2. The generation@ transmission@ and distribution of electricity@ lumens@ communication signals@ and communication data through public and private utility systems that are installed and maintained under the exclusive control of utilities or their authorized representatives. 3. Utility facilities and functions of utilities that (a) either generate energy or signals or accept energy or signals from another entity and (b) provide that energy or signals through a delivery point to another entity. 4. Street and area lights that provide a supply of lumens where these facilities are supplied by underground or overhead conductors installed and/or maintained under the exclusive control of utilities (including their authorized contractors or other qualified persons. 5. Utility facilities and functions on the line side of the service point located on public or private property in accordance with legally established easements or rights-of-way@ contracts@ other agreements (written or by conditions of service)@ or as authorized by a regulating or controlling body. Agreements to locate utility facilities on property are required where easements are either (a) not obtainable (such as locating utility facilities on existing rights-of-way of railroads or other entities@ military bases@ federal lands@ Native American reservations@ lands controlled by a port authority@ or other governmental agency) or (b) not necessary (such as locating facilities necessary for requested service to a site). 6. Wiring within a supply station or in an underground facility that is (a) installed in accordance with Part I or Part 3 of this Code and maintained under the exclusive control of utilities and (b) necessary for the operation of the supply station or underground facility. 7. Utility facilities installed@ maintained@ and controlled by utilities on surface or underground mine sites@ including overhead or underground distribution systems providing service up to buildings or outdoor equipment locations on the line side of the service point. 8. Similar systems to those listed above that are under the exclusive control of qualified persons and authorized by a regulating or controlling body@ including those associated with an industrial complex or utility interactive system. B. Not covered See Figure 011-1. NESC rules do not cover: 1. Utilization equipment or premises wiring located beyond utility service points to buildings or outdoor installations@ or 2. Underground mine wiring or installations In ships@ railway rolling equipment@ aircraft@ or automotive equipment@ or 3. Luminaires not installed or maintained under exclusive control by utilities@ or 4. Industrial complex or utility interactive systems that are not controlled exclusively under utilities or qualified persons or are located on the premises wiring side of the service point. NOTE: For installations in ships@ refer to Title 46@ Code of Federal Regulations@ Parts 110-113. The National Electrical Code? (NEC?) (NFPA 70?@ 2011 Edition)(1) covers utilization wiring requirements beyond the service point and luminaires that are not controlled exclusively by utilities. C. Types of requirements 1. These rules specify: 011C1d a. Loadings and factors related to required strength of utility structures and supported facilities; b. Clearances and spacings between: (1) facilities of different utilities@(2) facilities of same utility@ and(3) utility facilities and public facilities; c. Grounding; and d. Other requirements related to the safeguarding of persons and facilities@ including associated safe work practices@ to be employed by a utility in the exercise of its function as a utility up to the service point. 2. Utilities operating under the NESC are required to maintain control over the system up to the service point to assure that: a. The system is engineered to meet the requirements of expected conditions@ and b. The personnel installing@ maintaining@ and operating the system and its components are qualified to do so@ are adequately supervised@ follow accepted engineering practices@ and use appropriate tools and safe work procedures. Purpose A. The purpose of the NESC is the practical safeguarding of persons@ utility facilities@ and affected property during the installation@ operation@ and maintenance of electric supply and communication facilities@ under specified conditions. NOTE: NESC rules are founded upon the fundamental principles used for safety of utility facilities@ and the NESC is globally accepted as good engineering practice. B. NESC rules contain the basic provisions@ under specified conditions@ that are considered necessary for the safeguarding of: 1. The public@ 2. Utility workers (employees and contractors)@ 3.Utility facilities@ 4. Electric supply and communication equipment connected to utility facilities@ and 5. Other facilities or premises adjacent to or containing utility facilities. C. NESC rules are intended to provide a standard of safe practices that can be adopted by public utilities@ private utilities@ state or local utility commissions or public sen!ice commissions@ or other boards or bodies having control over safe practices employed in the design@ installation@ operation@ and maintenance of electric supply@ communication@ street and area lighting@ signal@ or railroad utility facilities. D. This Code is not intended as a design specification or as an instruction manual. (1)Information on references can be found in Section 3.

NESC-2012由IEEE - The Institute of Electrical and Electronics Engineers@ Inc. 发布于 2012-01-01,并于 2011-08-26 实施。

NESC-2012 发布之时,引用了标准

NESC-2012的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 NESC-2012 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
NESC-2012
发布日期
2012年01月01日
实施日期
2011年08月26日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
引用标准
398
适用范围
A. Covered See Figure 011-1. The NESC covers: 1. Supply and communication facilities (including metering) and associated work practices employed by a public or private electric supply@ communications@ railway@ trolley@ street and area lighting@ traffic signal (or other signal)@ irrigation district or other community owned utility@ or a similar utility in the exercise of its function as a utility. 2. The generation@ transmission@ and distribution of electricity@ lumens@ communication signals@ and communication data through public and private utility systems that are installed and maintained under the exclusive control of utilities or their authorized representatives. 3. Utility facilities and functions of utilities that (a) either generate energy or signals or accept energy or signals from another entity and (b) provide that energy or signals through a delivery point to another entity. 4. Street and area lights that provide a supply of lumens where these facilities are supplied by underground or overhead conductors installed and/or maintained under the exclusive control of utilities (including their authorized contractors or other qualified persons. 5. Utility facilities and functions on the line side of the service point located on public or private property in accordance with legally established easements or rights-of-way@ contracts@ other agreements (written or by conditions of service)@ or as authorized by a regulating or controlling body. Agreements to locate utility facilities on property are required where easements are either (a) not obtainable (such as locating utility facilities on existing rights-of-way of railroads or other entities@ military bases@ federal lands@ Native American reservations@ lands controlled by a port authority@ or other governmental agency) or (b) not necessary (such as locating facilities necessary for requested service to a site). 6. Wiring within a supply station or in an underground facility that is (a) installed in accordance with Part I or Part 3 of this Code and maintained under the exclusive control of utilities and (b) necessary for the operation of the supply station or underground facility. 7. Utility facilities installed@ maintained@ and controlled by utilities on surface or underground mine sites@ including overhead or underground distribution systems providing service up to buildings or outdoor equipment locations on the line side of the service point. 8. Similar systems to those listed above that are under the exclusive control of qualified persons and authorized by a regulating or controlling body@ including those associated with an industrial complex or utility interactive system. B. Not covered See Figure 011-1. NESC rules do not cover: 1. Utilization equipment or premises wiring located beyond utility service points to buildings or outdoor installations@ or 2. Underground mine wiring or installations In ships@ railway rolling equipment@ aircraft@ or automotive equipment@ or 3. Luminaires not installed or maintained under exclusive control by utilities@ or 4. Industrial complex or utility interactive systems that are not controlled exclusively under utilities or qualified persons or are located on the premises wiring side of the service point. NOTE: For installations in ships@ refer to Title 46@ Code of Federal Regulations@ Parts 110-113. The National Electrical Code? (NEC?) (NFPA 70?@ 2011 Edition)(1) covers utilization wiring requirements beyond the service point and luminaires that are not controlled exclusively by utilities. C. Types of requirements 1. These rules specify: 011C1d a. Loadings and factors related to required strength of utility structures and supported facilities; b. Clearances and spacings between: (1) facilities of different utilities@(2) facilities of same utility@ and(3) utility facilities and public facilities; c. Grounding; and d. Other requirements related to the safeguarding of persons and facilities@ including associated safe work practices@ to be employed by a utility in the exercise of its function as a utility up to the service point. 2. Utilities operating under the NESC are required to maintain control over the system up to the service point to assure that: a. The system is engineered to meet the requirements of expected conditions@ and b. The personnel installing@ maintaining@ and operating the system and its components are qualified to do so@ are adequately supervised@ follow accepted engineering practices@ and use appropriate tools and safe work procedures. Purpose A. The purpose of the NESC is the practical safeguarding of persons@ utility facilities@ and affected property during the installation@ operation@ and maintenance of electric supply and communication facilities@ under specified conditions. NOTE: NESC rules are founded upon the fundamental principles used for safety of utility facilities@ and the NESC is globally accepted as good engineering practice. B. NESC rules contain the basic provisions@ under specified conditions@ that are considered necessary for the safeguarding of: 1. The public@ 2. Utility workers (employees and contractors)@ 3.Utility facilities@ 4. Electric supply and communication equipment connected to utility facilities@ and 5. Other facilities or premises adjacent to or containing utility facilities. C. NESC rules are intended to provide a standard of safe practices that can be adopted by public utilities@ private utilities@ state or local utility commissions or public sen!ice commissions@ or other boards or bodies having control over safe practices employed in the design@ installation@ operation@ and maintenance of electric supply@ communication@ street and area lighting@ signal@ or railroad utility facilities. D. This Code is not intended as a design specification or as an instruction manual. (1)Information on references can be found in Section 3.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号