AMS1428G-2010

Fluid@ Aircraft Deicing/Anti-Icing@ Non-Newtonian (Pseudoplastic)@ SAE Types II@ III@ and IV


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 AMS1428G-2010 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
AMS1428G-2010
发布日期
2010年12月01日
实施日期
2016年02月19日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
SAE - SAE International
引用标准
26
适用范围
Form This specification covers three types of deicing/anti-icing material@ each in the form of a non-Newtonian fluid. Non-Newtonian A fluid defined as non-Newtonian exhibits a different apparent viscosity value when tested at the same temperature@ using the same viscometer and spindle in a predetermined volume when the only variant is the rotational speed of the spindle. Typically@ the non-Newtonian fluid shear stress is not in direct proportion to its rate of flow. Pseudoplastic A fluid described as pseudoplastic shall exhibit reduced apparent viscosity values as the spindle speed is increased@ and revert to original flow behavior when the shear stress is removed. This shall be demonstrable at the temperatures listed in 3.2.3.2. Application This fluid may be used as follows: a. Unheated and undiluted@ or diluted for anti-icing b. Heated and undiluted for deicing/anti-icing as a one step process c. Diluted with water and heated for deicing/anti-icing@ as a one step process d. Diluted with water and heated as the deicing stage in a two-step process@ usually when used with the unheated and undiluted fluid as step two CAUTION: SAE Type II@ III and IV fluid@ especially when used in a one step process or in the first step of a two step process@ may cause residues to collect in aerodynamically quiet areas@ cavities and gaps. These residues can affect flight safety. Refer to ARP4737. Consult aircraft manufacturer's Aircraft Operations Manual@ Aircraft Maintenance Manual and service letters to determine any restrictions relating to the use of deicing/anti-icing fluids meeting this specification for the type and model of aircraft being treated. Refer also to ARP4737. Precautions The lowest operational use temperature (LOUT) for a SAE Type II@ III@ and IV fluid shall be determined for the neat (undiluted) fluid or for each intended use dilution and is the lowest temperature at which the fluid has been tested and certified as acceptable in accordance with the appropriate aerodynamic acceptance test (3.2.5) while still maintaining the 7 ??(13 ?? freezing point temperature buffer (See ARP4737). The fluid manufacturers' literature shall clearly state the LOUT for the neat fluid and intended use dilutions. The deicing/anti-icing formulation may be mildly toxic and contact with human skin and eyes should be avoided. Prolonged exposure to concentrations of vapor or windborne mists should be avoided. Consult the fluid manufacturers' Material Safety Data Sheet for further information. Caution should be exercised in the use of glycol-water deicing/anti-icing solutions in and around electrical/electronic circuitry with noble metal coated wiring or terminals which could make contact with the fluid. Exothermic reactions@ which may result in fire have been reported. This may occur where defectively insulated wires@ switches@ or circuit breakers carrying direct current are encountered. Fluids based on glycol shall contain an inhibitor to minimize this potential fire hazard. A fluid meeting this specification is unique to each manufacturer and may be adversely affected by mixing with other aircraft deicing/anti-icing fluids. Slippery conditions may exist on the ground@ or equipment following the deicing/anti-icing procedure. Deicing/anti-icing fluids should be compatible with carbon brake material. Refer to ARP4737 and the airplane manufacturer's maintenance and service documents for further information on fluid use. An industry standard test method for compatibility is under development. Safety - Hazardous Materials While the materials@ methods@ applications@ and processes described or referenced in this specification may involve the use of hazardous materials@ this specification does not address the hazards which may be involved in such use. It is the sole responsibility of the user to ensure familiarity with the safe and proper use of any hazardous materials and processes and to take necessary precautionary measures to ensure the health and safety of all personnel involved. Fluid Qualification It is not sufficient for a SAE type II@ III@ or IV fluid to meet all of the requirements of AMS1428 for airlines to be able to use it. For such a fluid to be used commercially@ it must also have holdover time guidelines and be identified on a list of qualified fluids acceptable to regulators. For information on the qualification process of an AMS1428 fluid@ refer to ARP5718.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号