This document is applicable to permanent fixed and floating structures in the Gulf of Mexico. In this document@ inspection refers to structural inspections only and does not include inspections of production equipment@ process piping@ electrical and instrumentation or other systems and components of the platform@ unless noted otherwise. Fixed structures include steel jacket or template platforms@ towers and compliant towers@ caissons@ minimum nonjacket and special structures that are fixed to the seafloor. Design of these structures generally follows API 2A-WSD guidelines. Floating structures include tension leg platforms (TLPs)@ spars@ deep draft caisson vessels@ semi-submersibles and any other type of floating or tethered structures. Design of these structures generally follows API 2T@ API 2FPS@ API 2SK@ API 2RD and API 2I guidelines. Post-hurricane structural inspections are not as comprehensive as@ or supplant the need for@ regular in-service inspections as may be detailed in the structure's in-service inspection plan (ISIP). This document describes post-hurricane structural inspection of structures designed in accordance with the following API documents: ?? API 2A-LRFD@ ?? API 2A-WSD@ ?? API 2FPS@ ?? API 2I@ ?? API 2RD@ ?? API 2SK@ ?? API 2T@ ?? API 2TD. These structures may also be designed and operated in accordance with regulatory and classification society guidelines and these should be applied as required.