UL Outline for Investigation Hip and Ridge Vents (Issue 3)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SUBJECT 2582-2015 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
SUBJECT 2582-2015
发布日期
2015年09月10日
实施日期
2015年09月12日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
16
适用范围
This Outline of Investigation covers requirements intended to evaluate the fire and wind-driven rain performance of roof hip or ridge vents. These requirements are intended to evaluate a hip or ridge vent's resistance to: a) Flame spread due to exposure to fire sources external to a building; b) Flame penetration resulting in flaming droplets; and c) Resistance to water infiltration to the interior attic space. Class A hip or ridge vents are considered effective against severe fire test exposures. Under such exposures@ shingles of this class@ afford a high degree of fire protection to the roof deck@ do not sip from position@ and are not expected to produce flying brands. Class B hip or ridge vents are considered effective against moderate fire test exposures. Under such exposures@ shingles of this class@ afford a moderate degree of fire protection to the roof deck@ do not slip from position@ and are not expected to produce flying brands. Class C hip or ridge vents are considered effective against light fire test exposures. Under such exposures@ shingles of this class@ afford a light degree of fire protection to the roof deck@ do not slip from position@ and are not expected to produce flying brands. Fire tests conducted in accordance with these requirements are intended to demonstrate the performance of hip or ridge vents during the types and periods of exposure involved@ but are not intended to determine the acceptability of hip or ridge vents for use after exposure to fire. These fire test methods do not provide a basis to compare expected performance under all actual fire conditions but they do provide a basis for comparison of the response of hip or ridge vents when subjected to fire sources that are described herein. Hip or Ridge vents complying with the requirements for wind-driven rain are not expected to withstand the wind forces of tornadoes@ cyclones@ or hurricanes. Hip or Ridge vents are required to comply also with the requirements for construction@ material specifications@ and performance as applicable to specific types@ designs@ sizes@ and arrangements. All such applicable additional requirements are not considered to be within the scope of these requirements for fire and wind-driven rain tests@ but are included in the applicable standards covering the material in question.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号