PUBL 1625-1979

Analysis of Temperature Effects on Gasoline Marketing Operations


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 PUBL 1625-1979 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
PUBL 1625-1979
发布日期
1979年01月01日
实施日期
2011年06月01日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
API - American Petroleum Institute
引用标准
168
适用范围
EXECUTIVE SUMMARY Radian Corporation@ under a previous contract to the American Petroleum Institute@ compiled and analyzed data obtained as part of a calendar year 1975 gasoline temperature survey conducted by the EF-14 Task Force. Data were collected from fifty-six service stations across the United States during all seasons of the year. The data collected included such items as station throughput. physical characteristics of sites@ meteorological data@ and product temperatures from three primary locations: (1) the underground storage tank@ (2) the service station dispenser@ and (3) the vehicle fuel tank. The analysis provided insight into the complex subject of gasoline temperature variations@ specifically as related to vapor shrinkage/growth during vehicle refueling. The primary purpose of this report is to present additional results related to gasoline temperature adjustment in the petroleum marketing distribution system. Separate analyses involving the temperature data base were performed and the significant results included: When the ambient temperature is between 65??and 85 of@ vapor shrinkage will occur overall some 89% of the time. Mathematical regression models can predict average dispensed gasoline temperatures within an accuracy of ?? 0.5 percent. The overall nationwide volume weighted average gasoline sales temperature is estimated as 6l.6?? In addition to the temperature data base analyses@ a comprehensive study was made of five different techniques for retail gasoline temperature adjustment and compared measurement precision with the corresponding cost to the nation. Temperature adjustment methods varied from a one-time meter adjustment based on estimated dispensed temperature to electronic compensators. The proportional volume uncertainty ranges from ?? 0.0075 (?? 0.75%) for one-time meter adjustment to ?? 0.0006 (?? 0.06%) for the electronic compensator. Additional cost for these methods ranges from $11 million to $1.2 billion. Although it was not included in this study@ a comprehensive analysis should be considered in future work since the current no-temperature compensation practice provides the u.S. consumer as-a-whole with a yearly average gasoline temperature near 60??




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号