61535 AMD 1-2012
AMENDMENT 1 Installation couplers intended for permanent connection in fixed installations (Edition 1.0)

AMENDEMENT 1 Coupleurs d’installation pour connexions permanentes dans les installations fixes (Edition 1.0)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 61535 AMD 1-2012 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
61535 AMD 1-2012
发布日期
2012年05月01日
实施日期
2012年05月31日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
10
适用范围
This standard applies to two up to five wire installation couplers including earth@ if provided@ with a rated voltage up to and including 500 V a.c. and a rated connecting capacity up to and including 10 mm? for permanent connection in indoor electrical installations. Installation couplers with additional contacts for voltages other than mains voltages are outside the scope of this standard. NOTE 1 Installation couplers according to this standard are used e.g. in prefabricated buildings@ installation cavities@ such as suspended floors and ceilings@ or cable tray systems@ cable ladder systems@ cable ducting systems and cable trunking systems or in commercial show rooms@ in partition walls and in any similar application or in furniture complying with IEC 60364-7-713. NOTE 2 This standard may be used as a guide for installation couplers with additional contacts for voltages other than mains voltages. NOTE 3 In the UK@ where installation couplers have more than 5 wires@ they shall meet the requirements of IEC 61535 as though they were included in the scope and shall be tested in such a way that all of the mains voltage pins are subjected to the same level of testing. NOTE 4 In the USA@ these installation couplers are not permitted to be used where they will not be visible after installation. An installation coupler consists of an installation female connector and an installation male connector for permanent connection not intended to be engaged or disengaged under load nor to be engaged or disengaged other than during first installation or during reconfiguration or maintenance of the wiring system in which installation couplers have been installed. This means that installation couplers are only intended for infrequent use. Installation couplers are not suitable for use in place of socket-outlet systems. Installation couplers are not suitable for use in place of devices for connecting luminaires (DCLs) according to IEC 61995 or luminaire supporting couplers (LSCs). NOTE 5 For lower limits of in-service temperatures the necessary information is given in the manufacturer's installation instructions. In locations where special conditions prevail@ as in ships@ vehicles and the like and in hazardous locations@ for example where explosions are liable to occur@ special constructions may be required. NOTE 6 Particular requirements for installation couplers e.g. for. use at higher ambient temperatures@ with higher mechanical durability (e.g. metal housings)@ with higher fire resistance and for use in control circuits (e.g. SELV)@ are under consideration. NOTE 7 National rules may have requirements concerning the accessibility of installation couplers. NOTE 8 Installation couplers are intended to be installed by instructed or skilled persons. NOTE 9 National rules may specify who is allowed to carry out the connection and disconnection of installation couplers.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号