60404-15-2016
Magnetic materials – Part 15: Methods for the determination of the relative magnetic permeability of feebly magnetic materials (Edition 1.1 Consolidated Reprint)

Matériaux magnétiques – Partie 15: Méthodes de détermination de la perméabilité magnétique relative des matériaux faiblement magnétiques (Edition 1.1 Consolidated Reprint)


60404-15-2016 发布历史

This part of IEC 60404 specifies a solenoid method@ a magnetic moment method@ a magnetic balance method and a permeability meter method for the determination of the relative magnetic permeability of feebly magnetic materials (including austenitic stainless steel). The magnetic balance and permeability meter methods are both comparison methods calibrated using reference materials to determine the value of the relative magnetic permeability of the test specimen. The relative magnetic permeability range for each of these methods is shown in Table 1. The methods given are for applied magnetic field strengths of between 5 kA/m and 100 kA/m. NOTE 1 The relative magnetic permeability range given for the magnetic balance method covers the inserts provided with a typical instrument. These can only be assessed at values for which calibrated reference materials exist. NOTE 2 For a relative magnetic permeability larger than 2@ a reference material cannot be calibrated using this written standard. A note of this is given in the test report explaining that the values measured using the magnetic balance are for indication only. The solenoid method is the reference method. The magnetic moment method described is used mainly for the measurement of the relative magnetic permeability of mass standards. Two comparator methods used by industry are described. These can be calibrated using reference materials for which the relative magnetic permeability has been determined using the reference method. When suitable@ the magnetic moment method can also be used. The dimensions of the reference material need to be given careful consideration when determining the uncertainty in the calibration value due to self-demagnetization effects. See Annex A for more information on correcting for self-demagnetization.

60404-15-2016由IEC - International Electrotechnical Commission 发布于 2016-12-01,并于 2016-12-07 实施。

60404-15-2016的历代版本如下:

  • 2012年09月01日 60404-15-2012 Magnetic materials – Part 15: Methods for the determination of the relative magnetic permeability of feebly magnetic materials (Edition 1.0)
  • 2016年12月01日 60404-15-2016 Magnetic materials – Part 15: Methods for the determination of the relative magnetic permeability of feebly magnetic materials (Edition 1.1 Consolidated Reprint)

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60404-15-2016 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
60404-15-2016
发布日期
2016年12月01日
实施日期
2016年12月07日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
98
适用范围
This part of IEC 60404 specifies a solenoid method@ a magnetic moment method@ a magnetic balance method and a permeability meter method for the determination of the relative magnetic permeability of feebly magnetic materials (including austenitic stainless steel). The magnetic balance and permeability meter methods are both comparison methods calibrated using reference materials to determine the value of the relative magnetic permeability of the test specimen. The relative magnetic permeability range for each of these methods is shown in Table 1. The methods given are for applied magnetic field strengths of between 5 kA/m and 100 kA/m. NOTE 1 The relative magnetic permeability range given for the magnetic balance method covers the inserts provided with a typical instrument. These can only be assessed at values for which calibrated reference materials exist. NOTE 2 For a relative magnetic permeability larger than 2@ a reference material cannot be calibrated using this written standard. A note of this is given in the test report explaining that the values measured using the magnetic balance are for indication only. The solenoid method is the reference method. The magnetic moment method described is used mainly for the measurement of the relative magnetic permeability of mass standards. Two comparator methods used by industry are described. These can be calibrated using reference materials for which the relative magnetic permeability has been determined using the reference method. When suitable@ the magnetic moment method can also be used. The dimensions of the reference material need to be given careful consideration when determining the uncertainty in the calibration value due to self-demagnetization effects. See Annex A for more information on correcting for self-demagnetization.