SUBJECT 2577-2010

OUTLINE OF INVESTIGATION FOR SUSPENDED CEILING GRID LOW VOLTAGE LIGHTING SYSTEMS (Issue Number: 3)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SUBJECT 2577-2010 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
SUBJECT 2577-2010
发布日期
2010年12月17日
实施日期
2010年12月21日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
40
适用范围
These requirements cover suspended ceiling grid@ low voltage lighting systems and components intended for permanent installation and for use in a suspended ceiling grid in accordance with Article 411 of the National Electrical Code@ ANSI/NFPA 70. The suspended ceiling grid@ low voltage lighting systems covered by this outline are intended to be installed in a suspended ceiling grid that provides mechanical support for the ceiling tiles and provides electrical connections between the low voltage power supply and the low voltage luminaires. The low voltage lighting system consists of the following components: a) An isolating type low voltage power supply operating at 30 V (42.4 V peak) or less and not exceeding Class 2 power limits@ b) A grid rail power distribution system to provide power from the Class 2 power supply to one or more Class 2 powered luminaires@ and c) Class 2 powered luminaires that may be recessed into the suspended ceiling@ surface mounted on the room side of the ceiling@ or located below the suspended ceiling. The suspended ceiling grid@ low voltage lighting system is intended to be permanently connected@ for indoor dry locations@ commercial use only@ and installed in accordance with the National Electrical Code@ ANSI/NFPA 70@ the International Building Code@ and the International Mechanical Code requirements. This outline also covers suspended ceiling grid@ low voltage lighting systems intended use in for use air-handling spaces. This outline does not cover suspended ceiling grid@ low voltage lighting systems intended for use in: a) Hazardous locations as specified in the National Electrical Code@ ANSI/NFPA 70@ b) General patient care areas or critical patient care areas as defined by Article 517 of the National Electrical Code@ ANSI/NFPA 70@ c) Emergency systems as defined by Article 700 of the National Electrical Code@ ANSI/NFPA 70. This outline does not evaluate the suspended ceiling grid@ low voltage lighting system for seismic requirements in accordance with the International Building Code. This outline does not evaluate the suspended ceiling grid@ low voltage lighting systems for fire resistance.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号