ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups.
This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of accelerometers at low frequencies. It applies to all kinds of pick-ups.
This part of ISO 5347 is applicable for a frequency range from 0,5 Hz to 20 Hz and a dynamic range from 1 m/s to 200 m/s (frequency-dependent) and from 0,5 mm to 1 000 mm.
The limits of uncertainty applicable are ±0,5 % of reading.