OR-10-003-2010

Top-Level Energy and Environmental Dashboard for Data Center Monitoring


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 OR-10-003-2010 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
OR-10-003-2010
发布日期
2010年01月01日
实施日期
2010年05月17日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc.
引用标准
5
适用范围
"INTRODUCTION Have you ever asked yourself why the automobile's dashboard looks the way it does? The four top-level gauges are generally the speedometer@ the fuel gauge@ the engine-temperature gauge@ and the clock. They provide the most important information a driver needs to know to stay out of trouble and keep moving. A second tier of warning icons are hidden from view until something goes wrong with the vehicle (e.g.@ check engine icon) or the behavior of the passengers (e.g.@ fasten seatbelt icon). This hierarchy is a time tested way of arranging the information provided to the driver. A data center facility should provide an adequate thermal IT-equipment environment while minimizing infrastructure energy usage. Curbing energy consumption in energy intensive data centers is important for economic reasons and ensuring a satisfactory operating thermal environment is important for protecting IT-equipment from failure. However@ there is a perceived conflict between these two important goals. The most scrutinized link is ""air management@"" which essentially is about keeping cold and hot air from mixing. Cold supply air from the air handler should enter the heat-generating IT-equipment without mixing with ambient air and the hot exhaust air should return to the air handler without mixing. Managing the cold and hot air streams in data centers is important both for infrastructure energy management and IT-equipment thermal management. Air management has great potential to make data centers more energy efficient. Correctly implemented air management also has great potential to improve the thermal IT-equipment conditions. The information required to implement effective air management can be obtained by monitoring only three data entities: Infrastructure energy efficiency@ thermal IT-equipment conditions@ and air management effectiveness. A number of useful metrics have been developed over the past years. This paper lays out analogous rationale to the automobile dashboard as well as the justification for selecting three of those metrics for the proposed top-level energy and environmental dashboard for data center monitoring."




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号