GSO ASTM F1980:2024
无菌屏障系统和医疗器械加速老化的标准指南

Standard Guide for Accelerated Aging of Sterile Barrier Systems and Medical Devices


标准号
GSO ASTM F1980:2024
发布
2024年
发布单位
GSO
当前最新
GSO ASTM F1980:2024
 
 
适用范围
1.1 This guide provides information for developing accelerated aging protocols to model the possible effects of the passage of time on the sterile integrity of the sterile barrier system (SBS), as defined in ANSI/AAMI/ISO 11607–1: 2019 and the physical properties of their component packaging materials. Guidance for developing accelerated aging protocols may also be used for medical devices and medical device materials. 1.2 Information obtained using this guide may be regarded as sufficient evidence for expiration date claims for medical devices and sterile barrier systems until data from real-time aging studies are available. 1.3 The accelerated aging guideline addresses sterile barrier systems as a whole with or without devices. The sterile barrier system material and device interaction compatibility that may be required for new product development or the resulting evaluation is not addressed in this guide. 1.4 Real-time aging protocols are not addressed in this guide; however, it is essential that real-time aging studies be performed to confirm the accelerated aging test results using the same methods of evaluation. Real-time aging (stability) is the requirement of ANSI/AAMI/ISO 11607–1: 2019. 1.5 Methods used for sterile barrier system performance validation, which include, environmental challenge, distribution, handling, and shipping events, are used for package performance (event-related loss of integrity) testing and are beyond the scope of this guide. 1.6 This guide does not address environmental challenging that simulates extreme climactic conditions that may exist in the shipping and handling environment. Refer to Practice D4332 for standard conditions that may be used to challenge the sterile barrier system to realistic extremes in temperature and humidity conditions. See Terminology F17 for a definition of “environmental challenging.” 1.7 The data obtained from accelerated aging studies is not to be used as a manner of establishing label storage conditions for sterile barrier systems. 1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee

GSO ASTM F1980:2024相似标准


推荐

医疗器械灭菌包装密封性能验证标准及测试方法

标准等同于采用ISO 11607:2003《最终灭菌医疗器械包装》,规定了用于最终灭菌医疗器械包装一次性使用材料可再次使用容器要求,同时提出了评价无菌医疗器械包装性能基本要求,涉及到包装材料物理、化学、毒理学特性、微生物屏障成型包装密封/闭合性、完好性、老化性能等。这些性能要求最终以保证灭菌包装微生物隔绝作用为目的。...

烘箱在进行老化试验应用与操作

; YY/T 0681.1-2018 无菌医疗器械包装试验方法第1 部分 加速老化试验指南; GB/T 3984.2-2004 感应加热装置用电力电容器第2部分:老化试验、破坏试验内部熔丝隔离要求; FZ/T 01008-2008 涂层织物 耐热空气老化测定; ASTM D5423 - 14 StandardSpecification for Forced-Convection...

有源医疗器械使用期限评价方法

随着法规标准不断完善,以及认知水平和技术能力不断提高,相关内容也将适时进行修订。二、评价方法本评价方法依据《有源医疗器械使用期限注册技术审查指导原则》进行编写,通过可靠性分析、仿真计算、加速老化试验、疲劳测试、经验数据类比分析、风险分析等方法,对有源医疗器械进行验证,确定使用期限。本方法通过将有源医疗器械分解为不同子系统/部件方式进行评价。...

新版欧盟GMP无菌附录1变化- PUPSIT及应用

过滤器完整性测试在完整性测试过程中,过滤器下游要保持常压状态,所以下游应该能够通气。屏障式过滤器不仅能排液,也能排气,同时保证过滤器下游无菌性。屏障式过滤器支持通过气体及液体,可以快速系统排空,从而简化系统设计以及减少过滤器数量。系统吹扫并且保持无菌性在完整性测试结束之后,如果要进行系统吹扫,屏障式过滤器仍然可以在保证除菌过滤器下游无菌情况下,既排水又排气。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号