R 32-2019

Standard Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 R 32-2019 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
R 32-2019
发布日期
2019年01月01日
实施日期
2019年06月14日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
AASHTO - American Association of State Highway and Transportation Officials
引用标准
14
适用范围
This standard practice covers the annual calibration of the load cell and the deflection sensors and monthly relative calibration of the deflection sensors of a falling weight deflectometer (FWD) or a heavy weight deflectometer (HWD). It is used to establish calibration factors for correcting FWD and HWD measurements. For this practice@ the term ??FWD?? also refers to an HWD unless otherwise noted. This procedure is not applicable to the calibration of lightweight deflectometers or of cyclic loading and other types of pavement deflection testing equipment. A reference calibration is performed once per year or after the load cell has been replaced on the FWD. It shall be performed by a certified technician. Monthly relative calibration is performed on the deflection sensors at least once per month and immediately after a deflection sensor is replaced. A certified technician is not required. The procedure results in calibration factors that are entered into the FWD software as multipliers. When the FWD measurements are multiplied by the calibration factors@ the result is a set of measurements that have been corrected to agree with the calibration instrumentation. Calibration procedures may vary slightly among FWD types. This procedure can be used for all types of FWDs with minor modifications within the limits of the reference calibration equipment. This procedure has been automated in the software package WinFWDCal. It is required that the computer program be used to carry out the procedure. To use this procedure@ the FWD computer shall be capable of electronic data transfer. Data files for all types of FWDs can be read by the WinFWDCal software. The PDDX file format (Section 3.1.11) is required for data input. FWD data files that are in native format can be converted to PDDX format using PDDXconvert@ which is an integral component in WinFWDCal. The values stated in SI units are to be regarded as standard. U.S. Customary units given in parentheses are for information purposes only. This standard practice may involve hazardous materials@ operations@ and equipment. It does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard practice to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号