0600316-2008

Electrical Protection of Telecommunications Outside Plant


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 0600316-2008 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
0600316-2008
发布日期
2008年05月01日
实施日期
2011年04月28日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
ATIS - Alliance for Telecommunications Industry Solutions
引用标准
29
适用范围
Telecommunications outside plant covered in this standard This standard applies to the electrical protection@ bonding@ and grounding of telecommunications outside plant facilities. These facilities may consist of paired-conductor cable@ wire@ coaxial cable@ and optical fiber cable@ either singularly or in any combination@ and associated equipment such as closures@ pedestals@ electronic apparatus cases@ and cable terminals. The outside plant may be aerial@ direct buried@ or underground. The outside plant is the transmission media interconnecting telecommunications central offices and similar facilities as described in ATIS-0600313.2008@ Electrical protection for telecommunications central offices and similar type facilities@ to other such facilities or to the telecommunications customer premises at the telephone protector or equivalent location. The electrical protection@ bonding@ and grounding measures presented in this standard are intended to assist in protecting persons and property@ from the effects of lightning@ electric power systems@ and Electromagnetic Interference (EMI). Items not covered in this standard Specific EMI mitigation designs and the electrical protection of central offices and similar facilities@ microwave and radio tower structures@ the customer network interface@ and non-insulated open wire are not covered in this standard. Device-level specifications for electrical protection apparatus are not included in this standard. Optical fiber cables not under the exclusive control of a communications carrier@ or not meeting the requirements of ANSI C2@ National electrical safety code@ (see clause 2) for a communication line are not covered. Dedicated outside plant serving commercial or privately owned electric power generating stations and substations is not covered. Application of electrical protection The same degree of electrical protection may not be required on all outside plant. This standard defines@ based upon the electrical environment@ the criteria necessary to determine the electrical protection that should be applied. The primary consideration is the exposure of the outside plant to sources of unwanted voltage such as lightning and electric power. Other factors@ such as those relating to telecommunications service reliability@ may dictate the need for electrical protection measures exceeding those described in this standard.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号