UL Standard for Safety OUTLINE OF INVESTIGATION FOR SOLID STATE OVERCURRENT PROTECTORS (COMMENTS DUE: December 14@ 2009)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 2367 BULLETIN-2009 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
2367 BULLETIN-2009
发布日期
2009年10月30日
实施日期
2014年03月07日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
12
适用范围
This Outline of Investigation covers solid-state overcurrent protectors. These devices are solid-state switches that limit the output current to a safe level when the output load exceeds the current-limit threshold or when a load-side short-circuit is present. Solid-state overcurrent protectors are intended to be used on the load-side of an isolating transformer@ power supply or battery to provide a means of supplementary protection. See Table 1.1 for maximum current and power levels. The devices covered by these requirements are integrated circuits@ and electrical spacings within the devices are not specified. The devices covered by these requirements are entirely electronic in nature and have no means for manual operation or reset. The terminals of the devices covered by these requirements are for factory wiring only (intended to be mounted on a printed wiring board). The devices covered by these requirements shall only be used on supply circuits originating from an isolating transformer@ a power supply or a battery with limited maximum current and power levels as noted in Table 1.1. Use on supply circuits with a higher power capability requires additional evaluation for reliability@ such as those requirements contained in the Standard for Safety-Related Controls Employing Solid-State Controls@ UL 991. The devices covered by these requirements limit output currents to values less than the overcurrent protection rating of 5 amperes. The devices covered by these requirements have only been evaluated for supplementary overcurrent protection of secondary circuits supplied by the load side of a transformer@ power supply or battery and have not been evaluated for branch-circuit protection. This Outline of Investigation may cover devices intended for use in telecommunications applications. However@ devices intended for connection to telecommunications networks with outside plant connections should be evaluated in the end-use in accordance with the requirements of the Standard for Telephone Equipment@ UL 1459@ the Standard for Secondary Protectors for Communication Circuits@ UL 497A@ or the Standard for Information Technology Equipment@ UL 60950 as appropriate.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号