API RP 14F-2018

Recommended Practice for Design@ Installation@ and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I@ Division 1@ and Division 2 Locations (SIXTH EDITION)


API RP 14F-2018 发布历史

General This document recommends minimum requirements and guidelines for the design@ installation@ and maintenance of electrical systems on fixed and floating petroleum facilities located offshore. For facilities classified as Zone 0@ Zone 1@ or Zone 2@ reference API RP 14FZ@ Recommended Practice for Design@ Installation@ and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I@ Zone 0@ Zone 1@ and Zone 2 Locations. These facilities include drilling@ producing@ and pipeline transportation facilities associated with oil and gas exploration and production. This recommended practice is not applicable to mobile offshore drilling units (MODUs) without production facilities. This document is intended to bring together in one place a brief description of basic desirable electrical practices for offshore electrical systems. The recommended practices contained herein recognize that special electrical considerations exist for offshore petroleum facilities. These include the following: a) the inherent electrical shock possibility presented by the marine environment and steel decks; b) space limitations that require that equipment be installed in or near hazardous (classified) locations; c) the corrosive marine environment; d) motion and buoyancy concerns associated with floating facilities. This recommended practice applies to both permanent and temporary electrical installations. The guidelines presented herein should provide a high level of electrical safety when used in conjunction with welldefined area classifications. This recommended practice emphasizes safe practices for hazardous (classified) locations on offshore petroleum facilities but does not include guidelines for classification of areas; for guidance on the classification of areas refer to API RP 500. Applicability of the National Electrical Code Electrical systems for offshore petroleum facilities shall be designed and installed in accordance with the National Electrical Code (NEC)@ 2017 edition@ except where specific departures are noted.

API RP 14F-2018由API - American Petroleum Institute 发布于 2018-10-01,并于 2018-10-23 实施。

API RP 14F-2018 发布之时,引用了标准

API RP 14F-2018的历代版本如下:

  • 1985年07月01日 API RP 14F-1985
  • 1991年01月01日 API RP 14F-1991
  • 1999年06月01日 API RP 14F-1999 海上固定和浮式生产设施非危险区域.1级1类和2类区域电器系统设计与安装.第4版
  • 2008年07月01日 API RP 14F-2008 未分级和1级、1类和2类区域用海上固定和浮式石油设备电气系统的设计、安装和维护.第5版
  • 2018年10月01日 API RP 14F-2018

API RP 14F-2018



标准号
API RP 14F-2018
发布日期
2018年10月01日
实施日期
2018年10月23日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
API - American Petroleum Institute
引用标准
189
适用范围
General This document recommends minimum requirements and guidelines for the design@ installation@ and maintenance of electrical systems on fixed and floating petroleum facilities located offshore. For facilities classified as Zone 0@ Zone 1@ or Zone 2@ reference API RP 14FZ@ Recommended Practice for Design@ Installation@ and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I@ Zone 0@ Zone 1@ and Zone 2 Locations. These facilities include drilling@ producing@ and pipeline transportation facilities associated with oil and gas exploration and production. This recommended practice is not applicable to mobile offshore drilling units (MODUs) without production facilities. This document is intended to bring together in one place a brief description of basic desirable electrical practices for offshore electrical systems. The recommended practices contained herein recognize that special electrical considerations exist for offshore petroleum facilities. These include the following: a) the inherent electrical shock possibility presented by the marine environment and steel decks; b) space limitations that require that equipment be installed in or near hazardous (classified) locations; c) the corrosive marine environment; d) motion and buoyancy concerns associated with floating facilities. This recommended practice applies to both permanent and temporary electrical installations. The guidelines presented herein should provide a high level of electrical safety when used in conjunction with welldefined area classifications. This recommended practice emphasizes safe practices for hazardous (classified) locations on offshore petroleum facilities but does not include guidelines for classification of areas; for guidance on the classification of areas refer to API RP 500. Applicability of the National Electrical Code Electrical systems for offshore petroleum facilities shall be designed and installed in accordance with the National Electrical Code (NEC)@ 2017 edition@ except where specific departures are noted.