This non-destructive inspection method is needed to ascertain the following conditions: a. Innerlayer shift is within acceptable tolerances. b. One or more inner layers have not been reversed. c. Drilled holes are aligned with pads to the extent that any break-out is within acceptable tolerances. d. The minimum distance between a drilled hole and a ground plane clearance is within acceptable tolerances. The test method will entail passing X-rays through the test specimen and converting the transmitted X-ray image into a visual image through the use of either X-ray film or a flouro- scopic (real time) device.Cautionary notes: The construction of the multilayer with respect to; number of layers@ thickness of copper and presence other metals such as heat sinks (e.g. Invar)@ will determine the power and sensitivity of the X-ray apparatus which can be used. All X-ray apparatus should be registered with the appropriate state or regional Radiation Control agency. A radiation safety program should be implemented.