60601-2-17-2013
Medical electrical equipment Part 2-17: Particular requirements for the safety of automatically-controlled brachytherapy afterloading equipment (Edition 3.0)

Appareils électromédicaux Partie 2-17: Règles particulières de sécurité des appareils projecteurs de sources radioactives à chargement différé automatique utilisés en brachythérapie (Edition 3.0)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60601-2-17-2013 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
60601-2-17-2013
发布日期
2013年11月01日
实施日期
2013年11月29日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
96
适用范围
Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT@ hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only@ or to ME SYSTEMS only@ the title and content of that clause or subclause will say so. If that is not the case@ the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS@ as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This standard applies to automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT used for treatment or alleviation of disease. This standard specifies requirements a) for automatically-controlled AFTERLOADING ME EQUIPMENT 1) which contains and uses only beta@ gamma@ or NEUTRON-emitting SEALED RADIOACTIVE SOURCES@ or BRACHYTHERAPY X-RAY SOURCES designed and constructed for use with automatically-controlled AFTERLOADING ME EQUIPMENT@ 2) which automatically drives the RADIATION SOURCE(S) from a STORAGE CONTAINER or@ in the case of BRACHYTHERAPY X-RAY SOURCES@ a reference location outside the PATIENT@ to a treatment position inside the SOURCE APPLICATOR(S) and returns the RADIATION SOURCE(S) to the STORAGE CONTAINER or the BRACHYTHERAPY X-RAY SOURCE(S) to the reference location@ 3) which is designed for connection to a PATIENT@ and 4) with which movements of the RADIATION SOURCE(S) are carried out automatically by the ME EQUIPMENT according to a prescribed programme using a powered mechanism whose changes are controlled by the CONTROLLING TIMER(S) and TIMING DEVICES that are either PROGRAMMABLE ELECTRONIC SUB-SYSTEMS (PESS) (computer or microprocessors) or non-programmable systems and b) for ME EQUIPMENT intended to be 1) for NORMAL USE@ operated under the authority of appropriately licensed or QUALIFIED PERSONS by OPERATORS having the required skills for a particular medical application@ for particular specified clinical purposes@ e.g. remote AFTERLOADING BRACHYTHERAPY; 2) maintained in accordance within the recommendations given in the INSTRUCTIONS FOR USE; 3) subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON. This standard does not specify requirements for SEALED RADIOACTIVE SOURCES. Requirements for the design of X-RAY TUBES used with the ME EQUIPMENT are specified in other IEC standards. See for example: IEC 60601-2-28:2010. The requirements of this standard are based on the assumptions that: ?C a TREATMENT PLAN is available that prescribes appropriate values of the TREATMENT PARAMETERS@ and ?C the SOURCE STRENGTH(S) or the REFERENCE AIR-KERMA RATE of the RADIATION SOURCE(S) used by the ME EQUIPMENT is (are) known. This standard includes requirements intended to ensure that the prescribed values of the TREATMENT PARAMETERS can be achieved by the ME EQUIPMENT@ in particular that: ?C the selected RADIATION SOURCE(S) is (are) positioned or moved within the SOURCE APPLICATOR in the selected configuration relative to the SOURCE APPLICATOR; ?C IRRADIATION is performed by the selected RADIATION SOURCE configuration for the selected duration; ?C IRRADIATION is performed by the ME EQUIPMENT without causing unnecessary RISK to the OPERATOR or other persons in the immediate surroundings.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号