MS 12-2010

QUANTIFICATION AND MAPPING OF GEOMETRIC DISTORTION FOR SPECIAL APPLICATIONS


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 MS 12-2010 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
MS 12-2010
发布日期
2010年01月01日
实施日期
2017年03月09日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
NEMA - National Electrical Manufacturers Association
引用标准
24
适用范围
This standards publication defines test methods for measuring the absolute spatial variation of geometric accuracy within MR images. This standard presents the absolute geometric accuracy as a map@ graph@ or table throughout the imaging region rather than as simple figures of merit such as average or worst case error. Specifying both the acquisition and data presentation methods is the key function of this standard because the results are not easily reduced to a few simple figures of merit; the results are spatial in nature. This standard deals exclusively with absolute error measurements because it is assumed the end user will need geometric distortion error measurements in absolute versus relative terms. While the intent of this standard is to quantify equipment induced geometric errors only@ the phantom used for these measurements will also introduce some geometric errors. It is not possible to remove the phantom induced errors within the scope of this standard@ and this standard assumes that the measured errors are exclusively equipment errors. Therefore it is necessary for the user of this standard to be able to differentiate between geometric errors due to the MR imaging system and errors that arise from measuring geometric distortion with a test object. The user should attempt to estimate the error the phantom introduces for the specific test conditions used. This standard also recognizes that these measurements are ideally performed with three dimensional acquisitions and large volume phantoms@ but the cost@ weight@ and size of the required phantom may be prohibitive in certain situations. Therefore@ this standard permits the use of a substantially two dimensional phantom in conjunction with a set of two dimensional image acquisitions in different orientations. It is recognized that the use of a two dimensional phantom will fundamentally undersample the three dimensional spatial error map. These procedures could also be helpful in evaluating the impact of system changes on performance@ for quality control programs that seek to continually reaffirm system performance@ or in demonstrating effectiveness for FDA applications. However@ this standard does not supercede MS 2@ ??Determination of Two-Dimensional Geometric Distortion in Diagnostic Magnetic Resonance Images.?? Standard MS 2 is designed to produce simple figures of merit that describes basic geometric distortions@ or image field of view errors@ that could arise from imaging gradient amplitude scaling errors.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号