514B-2012

UL Standard for Safety Conduit@ Tubing@ and Cable Fittings (Sixth Edition; Reprint with revisions through and including June 4@ 2014)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 514B-2012 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
514B-2012
发布日期
2012年07月13日
实施日期
2014年11月25日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
148
适用范围
These requirements cover FITTINGS for use with cable and conduit intended for installation in accordance with the National Electrical Code@ ANSI/NFPA 70@ the Canadian Electrical Code (CEC)@ Part I@ CSA C22.1@ and the Standard for Electrical Installations@ NOM-001-SEDE. These requirements cover CONDUIT LOCKNUTS@ conduit BUSHINGS@ metal stud BUSHINGS@ CONDUIT BODIES@ and entrance ELBOWS; FITTINGS for electrical metallic tubing@ flexible metal conduit@ intermediate metal conduit@ liquid-tight flexible conduit@ rigid metal conduit@ and SERVICE-ENTRANCE HEADS; FITTINGS or box clamps referenced from other standards for armored cable@ metal-clad cable@ aluminum-sheathed cable@ mineral-insulated cable@ nonmetallic-sheathed cable@ service-entrance cable@ and tray cable@ and submersible FITTINGS; FITTINGS for flexible cord@ flexible nonmetallic and metallic tubing@ INSULATING BUSHINGS@ grips@ reducing washers@ and NIPPLES. Note 1: In Canada@ fittings for metal-clad (MC) cable@ intermediate metal conduit (IMC)@ flexible metallic tubing@ flexible nonmetallic tubing@ and CONDUIT BODIES are not recognized. CONDUIT BODIES are considered FITTINGS. Note 2: In Canada@ armored cable includes Type TECK cable. Note 3: In Canada@ tray cable includes any 'TC rated' cable. Note 4: In Mexico and the United States@ requirements for submersible FITTINGS are provided in NMX-J-235/2-ANCE or UL 50E. Note 5: In Mexico@ intermediate metal conduit is designated as semi-heavy metal conduit. In Mexico and the United States@ these requirements cover CONDUIT BODIES for rigid polyvinyl chloride (PVC) conduit. These products are intended to be used with Schedule 40@ Type EB@ Type A and Schedule 80 PVC conduit@ ELBOWS@ and other bends. In Canada@ requirements for fittings intended for use with rigid PVC conduit are addressed in CSA C22.2 No. 85. These requirements do not cover FITTINGS intended for use in hazardous locations as defined in the National Electrical Code@ ANSI/NFPA 70@ the Canadian Electrical Code (CEC)@ Part I@ CSA C22.1@ and the Standard for Electrical Installations@ NOM-001-SEDE. These requirements do not cover FITTINGS intended for use with surface raceway systems. These requirements do not cover conduit NIPPLES@ threaded ELBOWS@ and threaded COUPLINGS intended for use with rigid metal conduit or intermediate metal conduit.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号