K.50-2016

Safe limits for operating voltages and currents in telecommunication systems powered over the network (Study Group 5)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 K.50-2016 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
K.50-2016
发布日期
2016年12月01日
实施日期
2018年04月19日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
ITU-T - International Telecommunication Union/ITU Telcommunication Sector
引用标准
28
适用范围
This Recommendation provides guidance on voltages and currents that may safely be used to power telecommunication systems that are part of the network of telecommunications service providers. These systems use the paired-conductor cables of the network to provide power to communicationsrelated equipment at remote locations. This equipment and the current-carrying conductors can be accessed in the energized state by service or skilled personnel without using insulated gloves or tools. These systems are not intended to extend a voltage-limited remote feeding telecommunication (RFT-V) or a current-limited RFT (RFT-C) circuit beyond the point of demarcation between the service provider and the end user or ordinary people. In addition@ exposed RFT-V and RFT-C circuits are not allowed to be accessible to ordinary people or end users. The systems that use RFT-C and RFT-V are located in the network between different telecommunication centres@ between a telecommunication centre and a telecommunications access facility or node@ and between a telecommunication centre and public network interfaces (PNIs). This Recommendation covers only systems that use continuous direct current (d.c.) powering. RFT circuits sometimes carry signalling or data on the conductors@ as well as delivering power. However@ in many cases the conductors are used to simply provide d.c. power and no signalling or data is present. This is becoming more commonplace@ as fibre is used more and more to transmit broadband data and twisted pair copper cable pairs are used to power remote telecommunications equipment. Figure 1-a shows the field of application in the network between different telecommunication centres. Figure 1-b shows the part of the access network where this Recommendation is applicable. If there is no access network equipment between the local exchange and the customer premises equipment to convert the RFT-V or RFT-C to telecommunication network voltage-1 (TNV-1)@ TNV-2@ TNV-3@ energy source class 1 (ES1) or energy source class 2 (ES2)@ this Recommendation does not apply. Guidance on work practices@ if these limits are exceeded@ can be found in [b-ITU-T Directives Vol. VI] and [b-ITU-T Directives Vol. VII]. NOTE 1 ?C Limits on permissible voltages that may occur because of exposure to power or electrified railway lines are provided in [b-ITU-T Directives]. NOTE 2 ?C Requirements for the safety of equipment that is part of the telecommunications network infrastructure are provided in [b-ITU-T K.51]@ [IEC 60950-1] and [IEC 62368-1].




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号