UL Outline for Investigation FOR FIRE TESTS FOR FIRE PROTECTIVE CURTAINS (COMMENTS DUE: April 24@ 2017)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 10D BULLETIN-2017 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 10D BULLETIN-2017 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 




购买全文,请联系:


标准号
10D BULLETIN-2017
发布日期
2017年03月10日
实施日期
2017年10月05日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
UL - UL
引用标准
10
适用范围
These requirements cover the evaluation of fire-protective curtain assemblies intended to provide supplemental@ passive fire protection as part of an engineered fire protection system. fire-protective curtain assemblies are horizontally or vertically oriented. Horizontally or vertically oriented fireprotective curtain assemblies provide nonstructural separation only@ and are not intended to be substituted for structural hourly rated partitions or opening protectives that have been tested for fire endurance and hose stream performance. Note: fire-protective curtains do not include proscenium type (theater type) curtains. This document does not apply to proscenium type curtains in assembly occupancies for legitimate stages. Tests made in conformity with these test methods are intended to register performance during the test exposure;. but Such tests shall not be construed as determining suitability for use after exposure to fire. It is the intent that tests made in conformity with these test methods allow for the development of data to enable regulatory bodies to determine the suitability of horizontally or vertically oriented fire-protective curtain assemblies for use in locations where fire protection of a specified duration is required. These methods are intended to evaluate the ability of fire-protective curtain assemblies to remain in a horizontal or vertical opening during a predetermined test exposure. The tests expose a specimen to a standard controlled fire exposure controlled to achieve specified temperatures throughout a specified time period. The exposure@ however@ is not representative of all fire conditions@ which vary with changes in ventilation@ and compartment size@ and configuration. It does@ however@ provide a relative measure of fire performance of horizontally or vertically oriented fire-protective curtain assemblies under these specified fire exposure conditions. Any variation from the construction or conditions that are tested is capable of substantially changing the performance characteristics of the horizontally or vertically oriented fire-protective curtain assembly. The test methods does not provide the following: a) Full information as to performance of all horizontally oriented fire-protective curtain assemblies in walls or floors constructed of materials other than those tested. b) Full information as to performance of all vertically oriented fire-protective curtain assemblies in walls constructed of materials other than those tested. c) Evaluation of the degree by which the horizontally or vertically oriented fire-protective curtain assembly contributes to the risk of fire by generation of smoke@ toxic gases@ or other products of combustion. d) A temperature limit on the unexposed side of the horizontally or vertically oriented fire-protective curtain assembly. e) Measurement of the degree of control or limitation of the passage of smoke or products of combustion through the fire-protective curtain assembly. Note: See limitations for the passage of smoke detailed in the Standard for Smoke Door Assemblies and Other Opening Protectives@ NFPA 105.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号