Energy-Saving Measures in a Classroom Using Low Pressure Drop Ceiling Supply Device – A Field Study


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 OR-16-C062-2016 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
OR-16-C062-2016
发布日期
2016年01月01日
实施日期
2016年04月05日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc.
引用标准
8
适用范围
Between 1990 and 2006 the energy use by ventilation systems in Swedish schools doubled. This is explained by high airflows in schools because of the high occupant density. Studies show that 87% of Swedish schools use constant air volume (CAV)@ and it is estimated that a change to variable air volume (VAV) could save 0.12-0.33 TWh (4.1*1012 - 1.1*1013 Btu) per year. Therefore the aim of this study is to investigate whether it is possible to replace displacement ventilation (DV) with mixing ventilation (MV) to create a comfortable indoor climate in a typical classroom and at the same time decrease the energy use by using VAV and Low Pressure Drop Ceiling Supply Device (LPDCSD). The study used two LPDCSDs which consist of circular channels with 190/228 round jets placed in an interlocking pattern@ with a horizontal one/two-way-direction. The field study was carried out in a school which is intended to be extensively renovated. The school currently has DV and CAV. The study was carried out by installing MV with LPDCSD in one of the typical classrooms. Several different air-flow rates were investigated using tracer-gas technology to measure the local mean age of the air in the occupied zone. Simultaneously@ thermal comfort and vertical temperature gradients were measured in the room. The results show nearly uniform distribution of the local mean age of air in the occupied zone@ even in the cases of relatively low air-flow rates. Since the mixing of air is more or less the same in the entire occupied zone VAV can be used to reduce air-flow rate based on the desired CO2-level. Because of the number of students in each classroom and the fact that changes in air-flow rates have no significant effect on the degree of mixing@ it is possible to reduce the air-flow rates for extended periods of time. Finally@ since the LPDCSD has a lower pressure-drop than the currently used supply devices and it is possible to use VAV to lower the airflows in cases with reduced heat loads@ it is possible to significantly reduce the energy usage in the school while maintaining the IAQ@ increasing the thermal comfort and the available floor area of the occupied zone.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号