Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 PREN 81-72-2018 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
PREN 81-72-2018
发布日期
2018年03月01日
实施日期
2018年03月15日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
CEN - European Committee for Standardization
引用标准
53
适用范围
This document specifies the additional or deviating requirements to prEN 81-20:2018 for new passenger and goods passenger lifts@ which may be used for firefighting and evacuation purposes under firefighters control. This document applies@ when the following conditions are fulfilled: ?? the lift well and the lift environment are designed to restrict the ingress of fire@ heat and smoke to the lift well@ machinery spaces and safe areas; ?? the building design limits the flow of water into the lift well; ?? the firefighters lift is not an escape route@ such as staircases; ?? the lift well and the lift environment are fire protected for at least to the same level as the building structure; ?? the power supply is secure and reliable; ?? the electrical cable providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; ?? a suitable maintenance and verification plan is implemented. This document does not cover: ?? the use of lifts with partially enclosed wells for use as firefighters lifts; ?? lifts installed in new or existing buildings@ which are not included in fire resisting building structure; ?? important modification to existing lifts. This document does not define: ?? the number of firefighters lifts and the floors to be served during firefighting operations; ?? size of safe area(s); ?? the use of other than the highest deck of a multi deck lift for firefighting operations. This document deals with the significant hazards@ hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. The following significant hazards are not dealt with in this standard and are assumed to be addressed by the building designer: ?? not having enough or correctly located firefighters lifts to move the firefighters up the building; ?? a fire in the firefighters lift well@ safe area@ machinery space or car; ?? the absence of building floor identification signs at any floor; ?? water management is not operating correctly.

PREN 81-72-2018系列标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号