OR-10-008-2010

Development and Validation of a Dynamic Air Handling Unit Model@ Part 2 (RP-1312)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 OR-10-008-2010 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
OR-10-008-2010
发布日期
2010年01月01日
实施日期
2010年05月18日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc.
引用标准
17
适用范围
"INTRODUCTION The objectives of this study are to develop and validate a dynamic air handling unit (AHU) model. The development process of the dynamic system model (referred to as 1312 model hereafter) that includes a single duct dual fan variable air volume (VAV) AHU system and four building zones served by the VAV AHU system are introduced in the companion paper (Li and Wen 2009). The 1312 model is developed in HVACSIM+ environment and is based on the E51 model developed from ASHRAE research project RP825 (Norford and Haves 1997). The test facility used for this study is also described in Li and Wen (2009). In this paper@ the validation strategy@ process@ and final results for 1312 model are described. Validation of Heating Ventilating@ and Air Conditioning (HVAC) and building zone simulation dynamic models is not a trivial issue. Detailed review about simulation code verification and validation is provided by Reddy et al. (2006). While verification deals with determining whether the equations are solved correctly@ validation involves solving the right Equations and comparing simulation results against field or experimental data. There are publications in the literature that discuss HVAC system dynamic model verification and validation such as those focus on (a) component models (Clark et al. 1985@ Zhou and Braun 2007); (b) primary systems (Henze et al. 1997@ Wang et al. 2000); and (c) air conditioning process and its interaction with building zones (Brandemuehl et al. 1990@ Ahmed et al. 1998). Two papers were found that specifically discussed AHU dynamic model validation: ? Chen and Deng (2006) developed a dynamic simulation model for a direct expansion VAV air conditioning system consisted of a VAV air distribution subsystem and a DX refrigeration plant. AHU model was part of the overall model. A test rig was developed for validating the model. However@ the validation process only included comparing model outputs and experimental data under an open loop step change of compressor speed (one speed adjustment). ? No real weather conditions or internal loads was applied to the model. Nassif et al. (2008) developed a series of simplified component models for an AHU@ a VAV terminal unit@ building zone@ and their control systems. Real operation data collected from the system control system were used to obtain model parameters. Model outputs were compared with system measurements. However@ the component models were not connected to each other and it was unknown how well the entire system model would perform if all component models were connected. The above literature review indicates that there is a lack of a comprehensive validation study for AHU dynamic models that compares the entire system model predictions with real operation data. In this study@ three perspectives of the 1312 AHU model are to be validated: 1. Parameters: during the model development process@ all parameters are obtained from either nominal design values or from manufacturer catalogs. Those values often do not reflect the true parameters for a real system. An important part of the validation process is to first ""tune/ calibrate"" the parameters in the simulation model from system measurements; 2. component models: component models used in HVACSIM+ may not be able to simulate the test facility AHU performance satisfactorily because HVACSIM+ component models generally represent new and ideal component behaviors; and 3. system performance: even after all component models perform satisfactorily@ the system performance may still not be satisfactory due to error propagation and numerical calculation stability."




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号