AGMA 05FTM20-2005
双驱动输送机减速器故障分析

Dual Drive Conveyor Speed Reducer Failure Analysis


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 AGMA 05FTM20-2005 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
AGMA 05FTM20-2005
发布
2005年
发布单位
美国齿轮制造商协会
 
 
引用标准
13--16 1998 Belt Conveyors for Bulk Materials Belt--Conveyor Drives CEMA. Engineering Conference ErnestoWiedenbrug Fifth edition Garry E. Paulson Motor Selection for Motors: A M Overheating Electric P.E. PH.D September Tenth CIM Maintenance/
适用范围
With increasing requirements, many conveyor systems utilize dual drive arrangements to increase output. Dual drives can provide an economical solution by utilizing smaller, more efficient, system designs. However, multiple drive conveyors must proportion the load between drives and load sharing without some type of control is difficult to achieve. This paper presents a case study on a failure analysis of a coal mine dual drive conveyor system that experienced gear reducer failures between 2 to 18months. Physical and metallurgical inspection of failed gearing did not indicate material or workmanship defects, but indicated overload. In order to determine the cause of the failures, strain gage load testing was performed. The testing of the conveyor drives revealed load sharing problems which that will be reviewed.

AGMA 05FTM20-2005相似标准


推荐





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号