SIS SS IEC 463:1983
核检测仪表.用于放射线防护的便携式低能量X或γ射线照射量率计

Nuclear instrumentation - Low energy X or gamma radiation portable exposure r?te meters and monitors for use in radiological protection


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SIS SS IEC 463:1983 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
SIS SS IEC 463:1983
发布
1983年
发布单位
SE-SIS
当前最新
SIS SS IEC 463:1983
 
 
适用范围
1.1 This recommendation applies to portable assemblies intended to measure exposure r?te due to X or gamma radiation of energy equal to or less than 60 keV for the purposes of radiation pro-tection, and which comprise at least: - a detector sub-assembly, (e.g., ionization chamber, G.M. counter tube, scintillation detector, etc), - a measuring sub-assembly, which may be connected together either rigidly or by means of a flexible cable, or incorporated into a single assembly. The recommendation applies only to those situations in which there is no beta radiation present at the point of measurement. 1.2 The recommendation is applicable in its entirety to the following assemblies defined in Clause 2 : - portable exposure r?te meters; - portable exposure r?te monitors. 1.3 The recommendation is also applicable to portable exposure r?te measuring assemblies designed for special applications (e.g. very high exposure r?tes). However, some of the specifications may need to be amended or supplemented according to the particular characteristics applicable to such assemblies. 1.4 If an assembly has been designed to carry out combined functions, it shall comply with the require-ments pertaining to each of these functions. If it has been designed to perform only one function, but is also capable of carrying out other functions, then it need comply only with the requirements for the first function. It would be desirable, however, for the assembly to meet the requirements pertaining to the other functions. 1.5 The requirements given below pertain to assemblies as defined in Sub-clause 1.1, and which are cur-rently being manufactured. It is possible, however, to use assemblies which do not meet the requirements set out below when such requirements are not deemed essential for a given purpose. In such cases, the requirements to be applied to the assemblies shall be specified by agreement between the manufacturer and the user, but the determination of the characteristics of the assemblies shall conform to the methods given in the present recommendations. 1.6 The recommendation is not applicable to the operating characteristics of the functional units or sub-assemblies for the display of information (e.g. indicating meters, recorders, alarms). The characteristics of such instruments shall be in conformity with the general specifications appro-priate to them. 1.7 This recommendation specifies, for the above described assemblies, general characteristics, general test procedures, radiation characteristics, electrical, mechanical, safety and environmental characteristics, and also the identification certificate.

SIS SS IEC 463:1983相似标准


推荐

医疗工作环境真的足够安全吗?

随着科技进步,医疗技术也在不断发展变化,而伴随医疗技术进步,各种各样先进医疗设备研制相继出现并投入使用,医疗辐射也随之而来。医疗辐射诊疗分为放射线诊疗(包含比如X射线、γ射线)以及核医学诊疗(包含比如放射性同位素试剂)两种。这些医疗辐射具有一定危害性,由于并非频繁接受照射,因此对人体危害相对较小。...

【材料】具有超长电荷传输寿命无金属卤化物钙钛矿单晶用于X射线探测

所以专业人员都需配备放射线剂量测定装置,检测含量是否超标。金属基钙钛矿半导体材料在X射线探测方面展示了巨大前景。但是由于金属具有较大密度从而有较大质量,在一些需要便携或者轻质量探测器场合并不适用,例如X射线防护服上携带检测装置,智能标签探测装置等。由于有机材料密度与人体当量接近更符合人体特征,且重量很轻,所以用于上述X射线检测是比较合适。...

实验室检验检测设备--x光机

于是,X射线诊断技术便成了世界上最早应用非刨伤性内脏检查技术。(二)X射线治疗X射线用于治疗,主要依据其生物效应,应用不同能量X射线对人体病灶部分细胞组织进行照射时,即可使被照射细胞组织受到破坏抑制,从而达到对某些疾病,特别是肿瘤治疗目的。...

《多晶X射线衍射技术与应用》-5

仅在一定曝光范围内照片黑度与曝光量成比例,黑度保持线性变化曝光范围仅约两个量级;曝光高则出现所谓“曝光不足”“曝光过度”问题。照片黑度也和波长有关。测量黑度简单方法是目估,较为准确测量方法则需要事先制作好黑度标准,或者用光电黑度来扫描测量。此外,照相方法比较费时。例如,在普通功率(40kV,40mA)下如要获得一张岩石样品X射线粉末衍射照片,一般需要半小时以上。...


SIS SS IEC 463:1983 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号