ASTM D5712-2005e1
用改进半空细胞法分析天然橡胶及其制品中水可萃取蛋白质的标准试验方法

Standard Test Method for Analysis of Aqueous Extractable Protein in Natural Rubber and Its Products Using the Modified Lowry Method


ASTM D5712-2005e1 中,可能用到以下仪器设备

 

Luminex 200 液相芯片仪

Luminex 200 液相芯片仪

默克生命科学

 

Guava easyCyte 12系统

Guava easyCyte 12系统

默克生命科学

 

Guava easyCyte 6系统

Guava easyCyte 6系统

默克生命科学

 

Guava easyCyte 6HT系统

Guava easyCyte 6HT系统

默克生命科学

 

guava easyCyte 5系统

guava easyCyte 5系统

默克生命科学

 

Guava easyCyte 5HT系统

Guava easyCyte 5HT系统

默克生命科学

 

默克Millicell ERS-2 电阻仪

默克Millicell ERS-2 电阻仪

默克生命科学

 

Vectra™全自动定量病理学工作站(6片连载型)

Vectra™全自动定量病理学工作站(6片连载型)

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

Vectra™全自动定量病理学工作站200片连载型

Vectra™全自动定量病理学工作站200片连载型

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞 AppliedBiosystems

 

autoMACS Pro 全自动磁性细胞分选仪

autoMACS Pro 全自动磁性细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® Tyto 流式细胞分选仪

MACSQuant® Tyto 流式细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

美天旎MACSQuant® X高通量流式细胞仪

美天旎MACSQuant® X高通量流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® 流式细胞仪

MACSQuant® 流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® VYB流式细胞仪

MACSQuant® VYB流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

ClonePix 2细胞克隆筛选系统

ClonePix 2细胞克隆筛选系统

美谷分子仪器(上海)有限公司

 

皮升泵LPP01-100(细胞注射器)-LongerPump

皮升泵LPP01-100(细胞注射器)-LongerPump

保定兰格恒流泵有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM D5712-2005e1 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM D5712-2005e1
发布日期
2005年
实施日期
废止日期
中国标准分类号
G40
国际标准分类号
83.040.10 (Latex and raw rubber)
发布单位
US-ASTM
适用范围

This test method, for the determination of protein levels in NR, is primarily intended to test NR materials for residual protein content. It is assumed that all who use this test method will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.

1.1 This test method covers an analytical test for determining the amount of total aqueous extractable protein associated with natural rubber (NR) and its products. Water soluble proteins are extracted in a buffer solution and then precipitated to concentrate them and also to separate them from water soluble substances that may interfere with the determination. The extracted protein is redissolved and quantified colorimetrically by the modified Lowry method using a protein standard.

1.2 For the purpose of this test method, the range of protein measurement will be based on the limit of detection and quantitation and recorded in micrograms per dm2 NR specimen.

1.3 The test method is designed to be accurate and compatible with the industrial environment.

1.4 Steps are included in this test method to minimize the effects of interfering substances.

1.5 It is recognized that other methods for the analysis of leachable proteins exist and these may be used for routine quality control purposes provided they have been validated and a correlation established against the reference method specified by this test method.

1.6 The values stated inSI units are to be regarded as the standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.