额定电压不超过33kV的电力电缆的选择,搬运和安装.第4部分:额定电流

The selection, handling and installation of electric power cables of rating not exceeding 33 kV Part 4: Current ratings


SANS 10198-4-2005 发布历史

This part of SANS 10198 covers current ratings for the following types of cables installed under stipulated standard conditions: a) 600/1 000 V two-core, three-core or four-core extruded solid dielectric-insulated armoured cables; b) 1,9/3,3 kV three-core extruded solid dielectric-insulated armoured cables; c) 1,9/3,3 kV to 19/33 kV three-core impregnated-paper-insulated cables either lead/lead-alloy covered and armoured or corrugated seamless aluminum sheathed; d) 3,8/6,6 kVto 19/33 kV three-core cross-linked polyethylene-insulated armoured cables; and e) 600/1 000 V to 19/33 kV cross-linked polyethylene-insulated aerial bundled conductor cables. 2 Rating factors for deviations from standard conditions of installation are tabulated and, in addition, short-circuit ratings for symmetrical and earth faults are given. NOTE Where other types of cable (e.g. single-core or unarmoured) are involved or where conditions of installation are unusual, reference should be made to the manufacturer of the cables to establish ratings.

SANS 10198-4-2005由ZA-SANS 发布于 2005,于 2010-04-16 废止。

SANS 10198-4-2005的历代版本如下:

  • 2005年 SANS 10198-4-2005 额定电压不超过33kV的电力电缆的选择,搬运和安装.第4部分:额定电流
  • 2010年04月16日 SANS 10198-4-2010 额定功率不超过33 kV的电力电缆选择,处理和安装.第4部分:电流额定值

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SANS 10198-4-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
SANS 10198-4-2005
发布日期
2005年
实施日期
废止日期
2010-04-16
国际标准分类号
29.240.20
发布单位
ZA-SANS
代替标准
SANS 10198-4-2010
适用范围
This part of SANS 10198 covers current ratings for the following types of cables installed under stipulated standard conditions: a) 600/1 000 V two-core, three-core or four-core extruded solid dielectric-insulated armoured cables; b) 1,9/3,3 kV three-core extruded solid dielectric-insulated armoured cables; c) 1,9/3,3 kV to 19/33 kV three-core impregnated-paper-insulated cables either lead/lead-alloy covered and armoured or corrugated seamless aluminum sheathed; d) 3,8/6,6 kVto 19/33 kV three-core cross-linked polyethylene-insulated armoured cables; and e) 600/1 000 V to 19/33 kV cross-linked polyethylene-insulated aerial bundled conductor cables. 2 Rating factors for deviations from standard conditions of installation are tabulated and, in addition, short-circuit ratings for symmetrical and earth faults are given. NOTE Where other types of cable (e.g. single-core or unarmoured) are involved or where conditions of installation are unusual, reference should be made to the manufacturer of the cables to establish ratings.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号