IEEE C 37.41-2008
高压(>1000 V)熔断器,熔断器和熔断,分配闭合式单极空气开关,熔断器断开开关以及与这些设备配套使用的熔断器连线和附件的设计试验

Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:IEEE C 37.41-2008 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEEE C 37.41-2008 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEEE C 37.41-2008
发布日期
2008年11月10日
实施日期
废止日期
中国标准分类号
K31
发布单位
US-IEEE
引用标准
ANSI C37.42 ANSI C37.46 ANSI C37.47 ANSI C63.2-1987 IEC 60282-1 IEC 60282-2 IEEE 4-1995 IEEE C37.20.3 IEEE C37.40 IEEE C37.43 IEEE C37.45 IEEE C37.48
被代替标准
IEEE C 37.41-2000
适用范围
This standard specifies design test requirements for high-voltage (above 1000 V) fuses, distribution enclosed single-pole air switches, disconnecting cutouts, fuse disconnecting switches, and accessories for use on ac power and distribution systems. Devices with rated maximum voltages to 170 kV are covered. The devices to which this standard applies are as follows: a) Distribution and power class expulsion type fuses b) Distribution and power class current-limiting type fuses c) Distribution and power class fuse disconnecting switches d) Item a) through item c) used in fuse enclosure packages e) Fuse supports of the type intended for use with distribution and power class fuses, and fuse disconnecting switches f) Fuse and disconnecting cutouts g) Disconnecting devices created by the use of a removable switch blade in a distribution or power class fuse support h) Distribution class enclosed single-pole air switches i) Distribution class and power class expulsion, current-limiting, and combination types of external capacitor fuses used with a capacitor unit, groups of units, or capacitor banks j) Backup current-limiting fuses (“motor-starter fuses”) used in conjunction with high-voltage Class E2 motor starters (see ANSI/UL 347-2000 [B1])1 k) Fuse links when used exclusively with distribution class and power class fuses, and distribution class and power class fuse disconnecting switches l) Item a) through item d) and item f) through item i) having integral load-break means This standard specifies the minimum testing requirements for fuses and related devices. Such standardization is needed to ensure uniform minimum product testing for devices within the document scope. Test areas covered are based on historical experience.

IEEE C 37.41-2008 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号