ISO 17633:2017
焊接消耗品.不锈钢和耐热钢的气体保护和非气体保护金属弧焊用药芯电极和焊条.分类

Welding consumables - Tubular cored electrodes and rods for gas shielded and non-gas shielded metal arc welding of stainless and heat-resisting steels - Classification


标准号
ISO 17633:2017
发布
2017年
发布单位
国际标准化组织
替代标准
ISO 17633:2017/Amd 1:2021
当前最新
ISO 17633:2017/Amd 1:2021
 
 
引用标准
EN 12073:1999 ISO 13916:1996 ISO 14175:2008 ISO 14344:2010 ISO 15792-1:2000 ISO 544:2011 ISO 6847:2013 ISO 6947:2011 ISO 80000-1:2009 ISO 8249:2000
适用范围
This document specifies requirements for classification of tubular flux and metal cored electrodes and rods, based on the all-weld metal chemical composition, the type of core, shielding gas, welding position and the all-weld metal mechanical properties, in the as-welded or heat-treated conditions, for gas shielded and non-gas shielded metal arc welding of stainless and heat-resisting steels. This document is a combined standard providing for classification utilizing a system based upon nominal composition or utilizing a system based upon alloy type. a) Clauses, subclauses, and tables which carry the suffix letter “A” are applicable only to products classified using the system based upon nominal composition. c) Clauses, subclauses, and tables which do not have either the suffix letter “A” or the suffix letter “B” are applicable to all products classified in accordance with this document. b) Clauses, subclauses, and tables which carry the suffix letter “B” are applicable only to products classified using the system based upon alloy type. This document does not use pulsed current for determining the product classification.

ISO 17633:2017相似标准


推荐

内部缺陷性质估判以及缺陷产生原因防止措施

产生这类缺陷原因主要是材未按规定温度烘干,焊条药皮变质脱落、焊芯锈蚀,焊丝清理不干净,手工时电流过大,电弧过长;埋时电压过高或网络电压波动太大;气体保护保护气体纯度低等。如果焊缝中存在着气孔,既破坏了焊缝金属致密性,又使得焊缝有效截面积减少,降低了机械性能,特别是存链状气孔时,对弯曲冲击韧性会有比较明显降低。...

探伤过程中常见缺陷判断及产生原因(ZT)

产生这类缺陷原因主要是材未按规定温度烘干,焊条药皮变质脱落、焊芯锈蚀,焊丝清理不干净,手工时电流过大,电弧过长;埋时电压过高或网络电压波动太大;气体保护保护气体纯度低等。如果焊缝中存在着气孔,既破坏了焊缝金属致密性,又使得焊缝有效截面积减少,降低了机械性能,特别是存链状气孔时,对弯曲冲击韧性会有比较明显降低。    ...

超声波探伤仪检测工件出现不同缺陷原因解析?

从各个方向探测,反射波大体相同,但稍一动探头就消失,密集气孔会出现一簇反射波,波高随气孔大小而不同,当探头作定点转动时,会出现此起彼落现象。   产生这类缺陷原因主要是材未按规定温度烘干,焊条药皮变质脱落、焊芯锈蚀,焊丝清理不干净,手工时电流过大,电弧过长;埋时电压过高或网络电压波动太大;气体保护保护气体纯度低等。...

探伤过程中常见缺陷判断及产生原因

从各个方向探测,反射波大体相同,但稍一动超声波探伤仪探头就消失,密集气孔会出现一簇反射波,波高随气孔大小而不同,当探头作定点转动时,会出现此起彼落现象。产生这类缺陷原因主要是材未按规定温度烘干,焊条药皮变质脱落、焊芯锈蚀,焊丝清理不干净,手工时电流过大,电弧过长;埋时电压过高或网络电压波动太大;气体保护保护气体纯度低等。...