ASTM ISO/ASTM 52303-15
辐射处理设施中吸收剂量映射的标准指南

Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities


标准号
ASTM ISO/ASTM 52303-15
发布
2015年
发布单位
美国材料与试验协会
当前最新
ASTM ISO/ASTM 52303-15
 
 
引用标准
ASTM E170 ASTM E178 ASTM E2232 ISO 11137-1
适用范围

4.1 This guide is one of a set of guides and practices that provide recommendations for properly implementing dosimetry in radiation processing. In order to understand and effectively use this and other dosimetry standards, consider first “Practice for Dosimetry in Radiation Processing,” ASTM/ISO 52628, which describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E10.01 series of dosimetry standards. In addition, ASTM/ISO 52628 provides guidance on the selection of dosimetry systems and directs the user to other standards that provide information on individual dosimetry systems, calibration methods, uncertainty estimation and radiation processing applications.

4.2 Radiation processing is carried out under fixed path conditions where (a) a process load is automatically moved through the radiation field by mechanical means or (b) a process load is irradiated statically by manually placing product at predetermined positions before the process is started. In both cases the process is controlled in such a manner that the process load position(s) and orientation(s) are reproducible within specified limits.

Note 2: Static irradiation encompasses irradiation of the process load using either manual rotation, no rotation or automated rotation.

4.3 Some radiation processing facilities that utilize a fixed conveyor path for routine processing may also characterize a region within the radiation field for static radiation processing, sometimes referred to as “Off Carrier” processing.

4.4 Many radiation processing applications require a minimum absorbed dose (to achieve a desired effect or to fulfill a legal requirement), and a maximum absorbed dose (to ensure that the product, material or substance still meets functional specifications or to fulfill a legal requirement).

4.5 Information from the dose mapping is used to:

4.5.1 Characterize the radiation process and assess the reproducibility of absorbed-dose values, which may be used as part of operational qualification and performance qualification.

4.5.2 Determine the spatial distribution of absorbed doses and the zone(s) of maximum and minimum absorbed doses throughout a process load, which may consist of an actual or simulated product.

4.5.3 Establish the relationship between the dose at a routine monitoring position and the dose within the minimum and maximum dose zones established for a process load.

4.5.4 Verify mathematical dose calculation methods. See ASTM Guide E2232.


ASTM ISO/ASTM 52303-15相似标准


推荐

名词解释汇总:微量 X射线断层扫描相关监测指标(四)

辐射剂量 CT等成像设备使用过程,操作人员和受检动物都需要注意射线防护。目前,通行辐射剂量度量方法有以下几种: l 照射量(exposure),指直接度量X射线对空气电离能力量,表示辐射场强度,从电荷量角度来反映射线强度。单位是库仑?千克-1(C?...

辐射单位及辐射有效剂量

校准紫外、可见分光光度计波长标准选型关于电热套常见问题问答如何正确使用电缆故障测试仪光谱仪厂家为你揭秘微型光谱仪维修时八大基本准则烟气设备运行注意事项烟气设备日常运营维护磁翻板液位计出现消磁原因智能流量计维修工作   热门资料下载更多   30KV氧化锌避雷器测试仪漏电保护器测试仪特点DSZ-100L真空滤油机DS 接地引下线导通测试仪智能型兆欧表产品特点FISHER调压阀HSR...

辐射处理食物存在损害人体隐患 真的是这样吗?

但是,根据我国国家标准GB7718-2011《食品安全国家标准 预包装食品标签通则》对辐照食品标示规定:“经电离辐射线或电离能量处理食品,应在食品名称附近标示”、“经电离辐射线或电离能量处理任何配料,应在配料表中标明”。这也就是为什么会在有些食品外包装产品名称附近标有“辐照食品”或在配料表中标有“香辛料采用辐照杀菌技术处理”等字样原因。  辐照是否会对食物和人体造成伤害?...

LUMEX荧光分析仪系列应用(一)—水样铀含量测定

1液态流出物中放射性核素监测项目主要包括:废水中 U 天然、226Ra、 210Pb、 210Po 含量, 同时测量液态流出物流量或排放量。2固体废物监测项目主要包括: 固体废物排放量; α、β放射性表面污染水平;固体废物 U天然和 226Ra; 废石、尾矿(渣) 等表面的γ辐射空气吸收剂量率。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号