1 This International Standard specifies a method for the determination of the flow time of paints, varnishes and related products that may be used to control consistency. A method for the adjustment of paints to the correct application consistency at the application temperature is described in the annex.
2 Three flow cups of similar dimensions, but having orifice diameters of 3, 4 and 6 mm, are specified. The method for their calibration is given.
3 The method is limited to testing materials for which the breakpoint of the flow from the orifice of the flow cup can be determined with certainty. This point is difficult to determine and reproduce for materials with flow times in excess of 100 s due to slowing-down effects.