ZH

RU

ES

nickel working temperature

nickel working temperature, Total:500 items.

In the international standard classification, nickel working temperature involves: Fasteners for aerospace construction, Aerospace electric equipment and systems, Thermodynamics and temperature measurements, Radiation measurements, Welding, brazing and soldering, Products of non-ferrous metals, Shipbuilding and marine structures in general, Protection of and in buildings, Installations in buildings, Insulating materials, Iron and steel products, Industrial automation systems, Materials for aerospace construction, Occupational safety. Industrial hygiene, Construction materials, Plastics, Burners. Boilers, Air quality, Non-ferrous metals, Heat recovery. Thermal insulation, On-board equipment and instruments, Aircraft and space vehicles in general, Linear and angular measurements, Textile machinery, Pipeline components and pipelines, Ergonomics, Electrical wires and cables, Fuels, Coatings and related processes used in aerospace industry, Fruits. Vegetables, Fasteners, Solar energy engineering, Medical equipment, Fluid storage devices, Measurement of force, weight and pressure, Optics and optical measurements, Inorganic chemicals, Road engineering, Organic chemicals, Sewing machines and other equipment for the clothing industry, Safety of machinery, Electrical accessories, Analytical chemistry.


Korean Agency for Technology and Standards (KATS), nickel working temperature

  • KS W ISO 8279:2007 Aerospace-Nuts, hexagonal, plain, normal height, normal across flats, with MJ threads, classifications:600 MPa(at ambient temperature)/120 ℃,600 MPa(at ambient temperature)/235 ℃, 900 MPa(at ambient temperature)/425 ℃, 1 100 MPa(at ambient temperature)/23
  • KS B 6203-2002(2022) Maximum working pressure and super heated steam temperature of stationary steam boilers
  • KS D ISO 11692-2003(2013) Ferritic-pearlitic engineering steels for precipitation hardening from hot-working temperatures
  • KS W ISO 8642:2007 Aerospace-Self-locking nuts with maximum operating temperature greater than 425 ℃-Test methods
  • KS B 6203-2002(2017) Maximum working pressure and super heated steam temperature of stationary steam boilers
  • KS W ISO 7481-2005(2020) Aerospace-Nuts, self-locking, with maximum operatingtemperature less than or equal to 425 ℃-Test methods
  • KS B 6203-1964 Maximum working pressure and super heated steam temperature of stationary steam boilers
  • KS A ISO 7243-2005(2021) Hot environments-Estimation of the heat stress on working man, based on the WBGT-index(wet bulb globe temperature)
  • KS W ISO 8641:2005 Aerospace-Self-locking nuts with maximum operating temperature greater than 425 ℃-Procurement specification
  • KS W ISO 5858:2008 Aerospace-Nuts, self-locking, with maximum operating temperature less than 425℃-Procurement specification
  • KS B 6203-2002 Maximum working pressure and super heated steam temperature of stationary steam boilers
  • KS W ISO 8642-2007(2018) Aerospace-Self-locking nuts with maximum operating temperature greater than 425 ℃-Test methods
  • KS W ISO 5858-2008(2018) Aerospace-Nuts, self-locking, with maximum operating temperature less than 425℃-Procurement specification
  • KS W ISO 8641-2005(2020) Aerospace-Self-locking nuts with maximum operating temperature greater than 425 ℃-Procurement specification
  • KS W ISO 7481:2005 Aerospace-Nuts, self-locking, with maximum operatingtemperature less than or equal to 425 ℃-Test methods
  • KS W 0932-1998 Aerospace-Self-locking, fixed, single-lug anchor nuts,reduced series, with counterbore, strength classification 1100MPa and maximum operating temperature 235 degrees C
  • KS M 3062-1994 Testing method for stiffness properties of plastics as a function of temperature by means of a torsion test
  • KS W 0620-1992(2009) AIRPLANE STRENGTH AND RIGIDITY, MISCELLANEOUS LOADS

European Committee for Standardization (CEN), nickel working temperature

  • EN 4612-013:2011 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 013: SX, TC and UC - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single ext
  • EN 4049-003:2006 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 C to 260 C - Part 003: Single core nickel chromium/nickel aluminium - Product standard
  • EN 14706:2012 Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature
  • EN 4049-004:2006 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 C to 260 C - Part 004: Two core nickel chromium/nickel aluminium shielded and jacketed - Product standard
  • EN 2997-001:2011 Aerospace series - Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures -65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak - Part 001: Technical specification
  • EN 2997-001:2017 Aerospace series - Connectors@ electrical@ circular@ coupled by threaded ring@ fire-resistant or non fire-resistant@ operating temperatures - 65 ��to 175 ��continuous@ 200 ��continuous@ 260 ��peak - Part 001: Technical specification
  • prEN 127-1-1980 CEN-heating boiler standard for boilers with operating temperature up to 100 C
  • EN 4611-008:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 008: BP - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Dual extruded wall for open applications with additional
  • EN 14707:2012 Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
  • HD 413.1 S1-1981 Operating conditions for industrial-process measurement and control equipment; part 1: temperature, humidity and barometric pressure
  • EN 4049-002:2005 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C to 260 °C - Part 002: General
  • prEN 127-2-1980 CEN-heating boiler standard for boilers made from steel with operating temperatures exceeding 100 C and for steam
  • prEN 127-3-1980 CEN-heating boiler standard for boilers made from cast-iron with operating temperatures exceeding 100 C and for steam
  • EN 4612-012:2011 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 012: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for op
  • EN 2346-002:2006 Aerospace series - Cable, electrical, fire resistant - Operating temperatures between - 65 °C and 260 °C - Part 002: General
  • EN 2267-002:2015 Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 °C and 260 °C - Part 002: General
  • EN 4057-304:2006 Aerospace series - Cable ties for harnesses - Test methods - Part 304: Loop tensile strength at maximum working temperature
  • EN 4011:2004 Aerospace series - Nuts, bihexagonal, self-locking, in heat resisting nickel base alloy NI-PH2601 (Inconel 718), silver plated - Classification: 1 550 MPa (at ambient temperature) / 600 degrees C
  • EN 4011:2003 Aerospace series - Nuts, bihexagonal, self-locking, in heat resisting nickel base alloy TI-P100HT (Inconel 718), silver plated - Classification: 1 550 MPa (at ambient temperature) /600癈

British Standards Institution (BSI), nickel working temperature

  • BS EN 4612-013:2011 Aerospace series. Cables, electrical, for general purpose, single and multicore assembly. XLETFE Family. Jacketed or screened and jacketed. SX, TC and UC. Nickel plated copper. Operating temperatures, between -65°C and 150°C. Single extruded wall for equi
  • BS EN 4049-003:2006 Aerospace series - Thermocouple extension cable - Operating temperatures between p 65 °C to 260 °C - Part 003: Single core nickel chromium/nickel aluminium - Product standard
  • BS EN 4049-003:2007 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C and 260 °C - Single core nickel chromium/nickel aluminium - Product standard
  • BS A 298:1988 Methods of test for self-locking nuts with maximum operating temperature greater than 425 °C
  • BS EN 3372-001:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Technical specification
  • BS ISO 8642:2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 degrees C. Test methods
  • BS EN 14706:2012 Thermal insulating products for building equipment and industrial installations. Determination of maximum service temperature
  • BS EN 14706:2006 Thermal insulation products for building equipment and industrial installations. Determination of maximum service temperature
  • BS EN 4049-004:2006 Aerospace series - Thermocouple extension cable - Operating temperatures between p 65 °C to 260 °C - Part 004: Two core nickel chromium/nickel aluminium shielded and jacketed - Product standard
  • BS EN 4049-004:2007 Aerospace series - Thermocouple extension cable - Operating temperatures between -650DC and 260 °C - Two core nickel chromium/nickel aluminium shielded and jacketed - Product standard
  • BS EN 2267-002:2005 Cables, electrical, for general purpose — Operating temperatures between -55 °C and 260 °C — Part 002: General
  • BS EN 2267-002:2006 Aerospace series. Cables, electrical, for general purpose. Operating temperatures between -55°C and 260°C. General
  • BS EN 2997-001:2011 Aerospace series. Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures -65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak. Technical specification
  • BS EN 2997-001:2017 Aerospace series. Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 C to 175 C continuous, 200 C continuous, 260 C peak. Technical specification
  • BS EN 3372-007:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Protective cover for plug - Product standard
  • BS EN 3372-002:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Specification of performance and contact arrangement
  • BS EN 3372-003:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Square flange receptacle - Product standard
  • BS EN 3372-011:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Dummy receptacle - Product standard
  • BS EN 3372-006:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Protective cover for receptacle - Product standard
  • BS EN 3372-009:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Receptacle, jam nut mounting - Product standard
  • BS EN 3372-008:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Free plug with grounding spring - Product standard
  • BS EN 2266-002:2006 Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 °C and 200 °C - General
  • BS EN 2346-002:2006 Aerospace series - Cable, electrical, fire resistant - Operating temperatures between -65 °C and 260 °C - General
  • BS EN 2266-002:2005 Cables, electrical, for general purpose - Operating temperatures between -55 °C and 200 °C - Part 002: General
  • BS ISO 8641:2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 °C - Procurement specification
  • BS EN 3372-005:2007 Aerospace series - Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures -65 °C to 175 °C or 200 °C continuous - Receptacle, hermetic, round flange, solder mounting - Product standard
  • BS EN 14707:2012 Thermal insulating products for building equipment and industrial installations. Determination of maximum service temperature for preformed pipe insulation
  • BS EN 14707:2005+A1:2007 Thermal insulating products for building equipment and industrial installations — Determination of maximum service temperature for preformed pipe insulation
  • BS EN 4049-002:2005 Thermocouple extension cable - Operating temperatures between -65 °C and 260 °C - Part 002: General
  • BS EN 2267-002:2012 Aerospace series. Cables, electrical, for general purpose. Operating temperatures between -55°C and 260°C. General
  • BS EN 2267-002:2015 Aerospace series. Cables, electrical, for general purpose. Operating temperatures between -55 C and 260 C. General
  • BS 2A 302:2000 Nuts, self-locking, with maximum operating temperatures less than or equal to 425°C. Procurement specification
  • BS 2A 295:2000 Nuts, self-locking, with maximum operating temperature less than or equal to 425°C. Test methods
  • DD IEC/TS 62492-1:2008 Industrial process control devices. Radiation thermometers - Technical data for radiation thermometers
  • BS 5422:2001 Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40 °C to +700 °C
  • BS 1041-3:1989 Temperature measurement - Guide to selection and use of industrial resistance thermometers
  • BS IEC 61624:1998 Guidance on the development of lists of maximum allowable temperatures for polymeric compounds used in electrotechnical equipment
  • PD IEC/TS 62492-2:2013 Industrial process control devices. Radiation thermometers. Determination of the technical data for radiation thermometers
  • BS EN 16465:2015 Plastics. Methods for the calibration of black-standard and white-standard thermometers and black-panel and white-panel thermometers for use in natural and artificial weathering
  • PD IEC/TS 62903:2018 Aerospace series. Connectors, electrical, rectangular, modular. Operating temperature 175 °C continuous. Technical specification
  • BS ISO 21013-4:2012 Cryogenic vessels. Pilot operated pressure-relief devices. Pressure-relief accessories for cryogenic service
  • BS EN 4057-304:2007 Aerospace series - Cable ties for harnesses - Test methods - Loop tensile strength at maximum working temperature
  • BS EN 4057-304:2006 Aerospace Series. Cable Ties for Harnesses. Test Methods. Part 304: Loop Tensile Strength at Maximum Working Temperature

PL-PKN, nickel working temperature

National Metrological Verification Regulations of the People's Republic of China, nickel working temperature

  • JJG 856-2015 radiation thermometer for work
  • JJG 130-2004 Liquid-in-Glass Thermometers for Working
  • JJG 985-2004 Reference Standard Facility of High Temperature Platinum Resistance Thermometers
  • JJG 415-2001 Verification Regulation of the Working Radiation Thermometers
  • JJG 67-2003 Verification Regulation of the Total Radiation Pyrometers
  • JJG 130-1984 Verification Regulation of Liquid-in-Glass Thermometers for Working
  • JJG 130-2011 Verification Regulation of Liquid-in-Glass Thermometers for Working
  • JJG 856-1994 Verification Regulation of the Working Radiation Thermometers Below 500℃
  • JJG 716-1991 Verification Regulation of 0~419.527℃ Working Standard Platinum Resistance Thermometer

YU-JUS, nickel working temperature

  • JUS L.F2.012-1995 Measurement of temperature in industrial process - Tables for thermocouple - Thermocouple N: nickel-chrome- silicium/nickel-silicium
  • JUS L.N4.201-1984 Operating conditions for industrial-process measurement and control equipment. Temperature, humidity and barometric pressure
  • JUS U.J5.150-1983 Elsctrical temperatule mennring.lntruments calibration tables of resistance elements for resistance thermometres
  • JUS N.C9.002-1985 Connecting wires having a rated voltage of20 kVand 25 kVD.C. and a maximum working temperature of 105 °Cfor use in television receivers
  • JUS N.C9.002-1980 Connecting wires having a rated voltage of20 kVan? 25 kVD.C. and a mcvcimum working temperature of 105 °Cfor use in television receivers

ASD-STAN - Aerospace and Defence Industries Association of Europe - Standardization, nickel working temperature

  • PREN 4049-003-1999 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003: Single Core Nickel Chromium/Nickel Aluminium Product Standard
  • PREN 4049-003-2004 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003: Single Core Nickel Chromium/Nickel Aluminium Product Standard (Edition P 1)
  • PREN 4049-004-1999 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 004: Two Core Nickel Chromium/Nickel Aluminium Shielded and Jacketed Product Standard
  • PREN 4049-004-2004 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 004: Two Core Nickel Chromium/Nickel Aluminium Shielded and Jacketed Product Standard (Edition P 1)
  • PREN 3646-008-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 008 - Plug (Edition: 5E)
  • PREN 4611-009-2004 Aerospace series Cables@ electrical@ for general purpose@ single and multicore assembly XLETFE Family Part 009: BJ - Nickel plated copper Operating temperatures@ between - 65 Degrees Celsius and 150 Degrees Celsius Single extruded wall for use as cable co
  • PREN 6049-008-2010 Aerospace series Electrical cables@ installation Part 008: Self-wrapping shielded (EMI) protective sleeve with nickel copper braid@ Flexible post installation operating temperature from ? 55 Degrees C to 200 Degrees C Product standard (Edition P 2)
  • PREN 3646-001-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees Celsius or 200 Degrees Celsius Continuous Duty Part 001: Technical Specification (Edition 6E)
  • PREN 2267-003-1991 Aerospace Series Electrical Cables for General Use Operating Temperatures between -55 and +260 Degrees Celsius Product Standard
  • PREN 2267-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +260 Degrees Celsius (Edition P 2)
  • PREN 2623-1986 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between - 55 Degrees Celsius and + 135 Degrees Celsius (Issue P 1)
  • PREN 2266-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +200 Degrees Celsius (Edition P 2)
  • PREN 2265-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +150 Degrees Celsius (Edition P 2)
  • PREN 3646-011-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 011 - Dummy Sealed Receptacle (Edition: 5E)
  • PREN 3646-010-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 010 - Flight Blank for Plug (Edition: 5E)
  • PREN 3646-009-1996 Aerospace Serie Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 009 - Flight Blank for Receptacle (Edition: 5E)
  • PREN 3646-003-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 003 - Square Flangs Sealed Receptacle (Edition: 4E)
  • PREN 3646-005-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 005 - Hermetic Square Flange Receptacle (Edition: 5E)
  • PREN 3646-002-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees Celsius or 200 Degrees Celsius Continuous Duty Part 002 - Specification of Performance and Contact Arrangements (Edition 4E)
  • PREN 3645-006-1996 Aerospace Series Connectors@ Electrical@ Circular@ Scoop-Proof@ Triple Start Threaded Coupling Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 006: Flight Blank for Receptacle Product Standard (Edition 11E)
  • PREN 3646-007-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 007: Round Flange Hermetic Receptacle Attached by Brazing (Edition: 5E)
  • PREN 2346-002-2005 Aerospace Series Cable@ Electrical@ Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 002: General (Issue P 2)
  • PREN 4611-007-2004 Aerospace series Cables@ electrical@ for general purpose@ single and multicore assembly XLETFE Family Part 007: Nickel plated copper Operating temperatures@ between - 65 Degrees Celsius and 150 Degrees Celsius Dual extruded wall for open applications UV l
  • PREN 4612-013-2005 Aerospace series Cables@ electrical@ for general purpose@ single and multicore assembly XLETFE Family jacketed or screened and jacketed Part 013: SX@ TC and UC - Nickel plated copper Operating temperatures@ between -65 Degrees C and 150 Degrees C Single e
  • PREN 4611-008-2004 Aerospace series Cables@ electrical@ for general purpose@ single and multicore assembly XLETFE Family Part 008: BP - Nickel plated cooper Operating temperatures@ between - 65 Degrees Celsius and 150 Degrees Celsius Dual extruded wall for open applications
  • PREN 4049-002-2004 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 002: General (Edition P 1)
  • PREN 3646-006-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty Part 006 - Jam-Nut Mounted Round Flange Hermetic Receptacle (Edition: 5E)
  • PREN 3646-004-1996 Aerospace Series Connectors@ Electrical@ Circular@ Bayonet Coupling - Operating Temperature 175 Degrees C or 200 Degrees C Continuous Duty PArt 004: Jam-Nut Mounted Round Flange Sealed Receptacle (Edition: 5E)

ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc., nickel working temperature

  • ASHRAE DA-00-3-5-2000 Impact of Heating Systems and Wall Surface Temperatures on Room Operative Temperature Fields
  • ASHRAE 4167-1998 The Effects of Temperature@ Light@ and Sound on Perceived Work Environment
  • ASHRAE HI-02-6-4-2002 Field Measurements of Operative Temperatures in Buildings Heated or Cooled by Embedded Water-Based Radiant Systems

Association Francaise de Normalisation, nickel working temperature

  • NF EN 4049-003:2008 Série aérospatiale - Câbles, thermocouple - Températures de fonctionnement comprises entre - 65 oC et 260 oC - Partie 003 : fil simple nickel chrome/nickel aluminium - Norme de produit
  • NF EN 4049-004:2008 Série aérospatiale - Câbles, thermocouple - Températures de fonctionnement comprises entre - 65 oC et 260 oC - Partie 004 : paire nickel chrome/nickel aluminium blindé gainé - Norme de produit
  • NF P52-306-1:1993 DTU 65.20 - Thermal insulation of circuits, appliances and accessories - Working temperature greater than ambient temperature - Part 1 : technical specifications.
  • NF L09-503:1978 Standardized electrical cables. Code for operating temperatures and for type of conductor coating.
  • NF P75-449*NF EN 14706:2012 Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature
  • NF X35-201:1994 Hot environments. Estimation of the heat stress on working man, based on the wbgt-index (wet bulb globe temperature).
  • NF P52-306-2:1993 DTU 65-20. Thermal insulation of circuits, appliances and accessories. Working temperature greater than ambient temperature. Part 2 : particular specifications.
  • NF L52-114-007:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 007 : nickel plated copper - Operating temperatures, between - 65 oC and 150 oC - Dual extruded wall for open applications - UV laser printabl
  • NF P75-449:2006 Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature.
  • NF L52-151-002*NF EN 2346-002:2006 Aerospace series - Cable, electrical, fire resistant - Operating temperatures between -65oC and 260oC - Part 002 : general
  • NF L24-600:1988 Aerospace. Self-locking nuts with maximum operating temperature greater than 425 degrees C. Test methods.
  • NF EN 4611-009:2012 Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 009 : BJ - Cuivre nickelé - Températures de fonctionnement comprises entre - 65 oC et 150 oC - Fil simple isolé utilisé comme âme ...
  • XP L52-255-002*XP PR EN 2265-002:1995 Aerospace series. Cables, electrical, for general purpose. Operating temperatures between - 55 degrees celsius and 150 degrees celsius. Part 002 : general.
  • NF ISO 11346:2014 Caoutchouc vulcanisé ou thermoplastique - Estimation de la durée de vie et de la température maximale d'utilisation
  • NF L52-275-002:2013 Aerospace series - Cables, electrical, for general purpose - Operating temperatures between - 55 oC and 260 oC - Part 002: general
  • NF L52-265-002*NF EN 2266-002:2006 Aerospace series : Cables, electrical, for general purpose - Operating temperatures between -55 oC and 200 oC - Part 002 : general
  • NF C74-387:1987 Electromedical equipment. Temperature monitoring equipment. Particular requirements for safety and operating.
  • NF E15-100:2000 Industrial pressure gauges and thermometers - Metallic indicator pressure gauges and thermometers - Pressure gauges and thermometers with control function
  • NF E15-100:1988 INDUSTRIAL PRESSURE GAUGES AND THERMOMETERS. METALLIC INDICATOR PRESSURE GAUGES AND THERMOMETERS. PRESSURE GAUGES AND THERMOMETERS WITH CONTROL FUNCTION.
  • NF L54-143-015*NF EN 2997-015:2011 Aerospace series - Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 oC to 175 oC continuous , 200 oC continuous, 260 oC peak - Part 015 : Jam-nut mounted receptacle with integrat
  • NF L54-130:1987 Connectors, electrical, circular, bayonnet coupling. Operating temperature 200 degrees C continuous duty. Light weight shell, type 6.
  • NF L22-500:2018 Fasteners - Nuts, self-locking, with maximum operating temperature less than or equal to 425 oC - Technical requirements
  • NF ISO 7633:1987 Véhicules routiers - Capuchons en caoutchouc pour cylindres de roue de freins hydrauliques à tambour utilisant un liquide de frein à base pétrolière (température maximale d'utilisation 120 degrés Celsius)
  • NF ISO 7632:1987 Véhicules routiers - Joints en caoutchouc pour cylindres de freins hydrauliques à disque utilisant un liquide de frein à base pétrolière (température maximale d'utilisation 120 degrés Celsius)
  • NF UTE C46-202:1988 Mesure et commande dans les processus industriels - Capteurs de température à résistances thermométriques en platine - Prescriptions de qualification
  • E66-504:1981 Cutting tool angles. General conversion formulae to relate tool and working angles.
  • NF L52-151-003*NF EN 2346-003:2006 Aerospace series - Cables, electrical, fire resistant - Operating temperatures between - 65 oC and 260 oC - Part 003 : DL family, single core - Product standard
  • NF EN 4611-007:2018 Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 007 : cuivre nickelé - Températures de fonctionnement comprises entre - 65 oC et 150 oC - Fil double isolé pour applications externe...
  • NF L52-320-002*NF EN 4049-002:2006 Aerospace series - Thermocouple extension cable - Operating temperatures between - 65 oC to 260 oC - Part 002 : general

Association of German Mechanical Engineers, nickel working temperature

German Institute for Standardization, nickel working temperature

  • DIN EN 4049-003:2008 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C to 260 °C - Part 003: Single core nickel chromium/nickel aluminium - Product standard; German and English version EN 4049-003:2006
  • DIN EN 4049-004:2008 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C to 260 °C - Part 004: Two core nickel chromium/nickel aluminium shielded and jacketed - Product standard; German and English version EN 4049-004:2006
  • DIN EN 4049-003:2008-05 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C to 260 °C - Part 003: Single core nickel chromium/nickel aluminium - Product standard; German and English version EN 4049-003:2006
  • DIN EN 10267:1998 Ferritc-pearlitic steels for precipitation hardening from hot-working temperatures; German version EN 10267:1998
  • DIN EN 4049-004:2008-05 Aerospace series - Thermocouple extension cable - Operating temperatures between -65 °C to 260 °C - Part 004: Two core nickel chromium/nickel aluminium shielded and jacketed - Product standard; German and English version EN 4049-004:2006
  • DIN 33403-5:1997 Climate at the workplace and its environments - Part 5: Ergonomic design of cold workplaces
  • DIN EN 4611-008:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 008: BP - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Dual extruded wall for open applications with additional
  • DIN EN 4611-009:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single extruded wall for use as cable cores or within equ
  • DIN EN 4611-007:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 007: Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Dual extruded wall for open applications - UV laser printable
  • DIN EN 27243:1993 Hot environments; estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature) (ISO 7243:1989); German version EN 27243:1993
  • DIN EN 4057-304:2008 Aerospace series - Cable ties for harnesses - Test methods - Part 304: Loop tensile strength at maximum working temperature; German and English version EN 4057-304:2006
  • DIN EN 4057-304:2008-02 Aerospace series - Cable ties for harnesses - Test methods - Part 304: Loop tensile strength at maximum working temperature; German and English version EN 4057-304:2006 / Note: Applies in conjunction with DIN EN 4057-100 (2008-02).
  • DIN EN 4612-011:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Dual extruded wall for ope
  • DIN EN 4612-012:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 012: Nickel plated copper - Operating temperatures between -65 °C and 150 °C - Dual extruded wall for open
  • DIN EN 4611-009:2012-04 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single extruded wall for use as cable cores or withi...
  • DIN EN 4612-013:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 013: SX, TC and UC - Nickel plated copper - Operating temperatures between -65 °C and 150 °C - Single extr
  • DIN EN 2346-002:2007 Aerospace series - Cable, electrical, fire resistant - Operating temperatures between -65 °C and 260 °C - Part 002: General; German and English version EN 2346-002:2006
  • DIN EN ISO 2578:1998 Plastics - Determination of time-temperature limits after prolonged exposure to heat (ISO 2578:1993); German version EN ISO 2578:1998

Military Standard of the People's Republic of China-General Armament Department, nickel working temperature

  • GJB 898-1990 General medical requirements for work cabin (room) temperature environment
  • GJB 282.1-1987 Armored Vehicle Environmental Conditions Operating Ambient Temperature
  • GJB 898A-2004 General medical requirements and evaluation of temperature environment of work cabin (room)
  • GJB 212.6-1986 Special industrial leather - Determination of shrinkage temperature

Lithuanian Standards Office , nickel working temperature

  • LST EN 4049-003-2007 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 °C to 260 °C - Part 003: Single core nickel chro-mium/nickel aluminium - Product standard
  • LST EN 4049-004-2007 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 °C to 260 °C - Part 004: Two core nickel chro-mium/nickel aluminium shielded and jacketed - Product standard
  • LST EN 27243-2001 Hot environments - Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature) (ISO 7243:1989)
  • LST EN 4612-012-2011 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 012: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for op
  • LST EN 4611-009-2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single extruded wall for use as cable cores or within equ

Indonesia Standards, nickel working temperature

  • SNI 16-7061-2004 The measurement of work climates (hot) by wet bulb globe temperature index parameters
  • SNI 04-4189-1996 Operational condition for measuring and industrial process control instruments - Part 1: Temperature, humidity and barometric pressure
  • SNI 16-7062-2004 The measurement of lighting intensities at work places

NO-SN, nickel working temperature

  • NS 5508-1978 Thermometers - Thermometer wells for industrial thermometers type C
  • NS 5509-1978 Thermometers - Glass inserts for industrial thermometers
  • NS 5507-1978 Thermometers - Industrial thermometers with glass inserts - V-shaped case

ES-UNE, nickel working temperature

  • UNE-EN 4049-003:2006 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 C to 260 C - Part 003: Single core nickel chro-mium/nickel aluminium - Product standard (Endorsed by AENOR in March of 2007.)
  • UNE-EN 4049-004:2006 Aerospace series - Thermocouple extension cable - Operating tempera-tures between - 65 C to 260 C - Part 004: Two core nickel chro-mium/nickel aluminium shielded and jacketed - Product standard (Endorsed by AENOR in March of 2007.)
  • UNE-EN 4057-304:2006 Aerospace series - Cable ties for harnesses - Test methods - Part 304: Loop tensile strength at maximum working temperature (Endorsed by AENOR in April of 2007.)
  • UNE-EN 4611-009:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single extruded wall for use as cable cores or withi...

Aerospace, Security and Defence Industries Association of Europe (ASD), nickel working temperature

  • ASD-STAN PREN 4049-003-2004 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003: Single Core Nickel Chromium/Nickel Aluminium Product Standard (Edition P 1)
  • ASD-STAN PREN 2997-004-2005 Aerospace Series Connectors, Electrical, Circular, Coupled by Threaded Ring, Fire-Resistant or Non Fire-Resistant, Operating Temperatures -65 Degrees C to 175 Degrees C Continuous, 200 Degrees C Continuous, 260 Degrees C Peak Part 004: Jam-Nut Mounted Rec
  • ASD-STAN PREN 4049-004-2004 Aerospace Series Thermocouple Extension Cable Operating Temperatures between -65 Degrees C and 260 Degrees C Part 004: Two Core Nickel Chromium/Nickel Aluminium Shielded and Jacketed Product Standard (Edition P 1)
  • ASD-STAN PREN 2997-008-2005 Aerospace Series Connectors, Electrical, Circular, Coupled by Threaded Ring, Fire Resistant or Non Fire-Resistant, Operating Temperatures - 65 Degrees to 175 Degrees C Continuous, 200 Degrees C Continuous, 260 Degrees C Peak Part 008: Plug Product Standar
  • ASD-STAN PREN 2997-001-2010 Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 Degrees C to 175 Degrees C continuous, 200 Degrees C continuous, 260 Degrees C peak Part 001: Technical specific
  • ASD-STAN PREN 2997-011-2009 Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 degree C to 175 degree C continuous, 200 degree C continuous, 260 degree C peak Part 011: Dummy receptacle Produ
  • ASD-STAN PREN 3372-002-2005 Aerospace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C and 200 Degrees C Continuous Part 002: Specification of Performance and Contact A
  • ASD-STAN PREN 3372-001-2005 Aerospace series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 001: Technical Specification (Edition P 1)
  • ASD-STAN PREN 4611-009-2004 Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 009: BJ - Nickel plated copper Operating temperatures, between - 65 Degrees Celsius and 150 Degrees Celsius Single extruded wall for use as cable co
  • ASD-STAN PREN 2997-002-2010 Aerospace Series Connectors, Electrical, Circular, Coupled by Threaded Ring, Fire-Resistant or Non Fire-Resistant, Operating Temperatures - 65 Degrees C to 175 Degrees C Continuous, 200 Degrees C Continuous, 260 Degrees C Peak Part 002: Specification of
  • ASD-STAN PREN 2997-016-2009 Aerospace series Connectors, electrical, circular, coupled be threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 degree C to 175 degree C continuous, 200 degree C continuous, 260 degree C peak Part 016: Plug with integrated a
  • ASD-STAN PREN 2623-1986 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between - 55 Degrees Celsius and + 135 Degrees Celsius (Issue P 1)
  • ASD-STAN PREN 6049-008-2010 Aerospace series Electrical cables, installation Part 008: Self-wrapping shielded (EMI) protective sleeve with nickel copper braid, Flexible post installation operating temperature from ? 55 Degrees C to 200 Degrees C Product standard (Edition P 2)
  • ASD-STAN PREN 2997-015-2009 Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 degree C to 175 degree C continuous, 200 degree C continuous, 260 degree C peak Part 015: Jam-nut mounted recept
  • ASD-STAN PREN 3372-005-2005 Aeropsace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 005: Receptacle, Hermetic, Round Flange, Solder
  • ASD-STAN PREN 3372-007-2005 Aerospace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 007: Protective Cover for Plug - Product Standar
  • ASD-STAN PREN 3372-003-2005 Aerospace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 003: Square Flange Receptacle - Product Standard
  • ASD-STAN PREN 3372-006-2005 Aeropsace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 006: Protective Cover for Receptacle - Product S
  • ASD-STAN PREN 3372-011-2005 Aerospace series Connectors, electrical, circular, medium and high contact density, scoop-proof with bayonet coupling, operating temperatures - 65 degrees C to 175 degrees C or 200 degrees C continous Part 011: Dummy receptacle Product standard (Edition P
  • ASD-STAN PREN 3372-008-2005 Aeropsace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 008: Free Plug with Grounding Spring - Product S
  • ASD-STAN PREN 4611-007-2004 Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 007: Nickel plated copper Operating temperatures, between - 65 Degrees Celsius and 150 Degrees Celsius Dual extruded wall for open applications UV l
  • ASD-STAN PREN 4612-012-2005 Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family jacketed or screened and jacketed Part 012: Nickel plated copper Operating temperatures, between -65 degrees C and 150 degrees C Dual extruded wall for o
  • ASD-STAN PREN 2997-012-2006 Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak Part 012: Jam-nut for jam-nut receptacles Product standa
  • ASD-STAN PREN 3372-009-2005 Aeropsace Series Connectors, Electrical, Circular, Medium and High Contact Density, Scoop-Proof with Bayonet Coupling, Operating Temperatures - 65 Degrees C to 175 Degrees C or 200 Degrees C Continuous Part 009: Receptacle, Jam Nut Mounting Product Standa
  • ASD-STAN PREN 2997-013-2006 Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 °C to 175 °C continuous, 200 °C continuous, 260 °C peak Part 013: O’ring seal for jam-nut receptacles Product st
  • ASD-STAN PREN 4611-008-2004 Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 008: BP - Nickel plated cooper Operating temperatures, between - 65 Degrees Celsius and 150 Degrees Celsius Dual extruded wall for open applications

National Aeronautics and Space Administration (NASA), nickel working temperature

American National Standards Institute (ANSI), nickel working temperature

  • ANSI/ASTM B637:1998 Specification for Precipitation Hardening Nickel Alloy Bars, Forgings, and Forging Stock for High-Temperature Service
  • ANSI/ASTM D6096:2011 Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 C Operation
  • ANSI/ASTM D2220:2011 Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75 C Operation
  • ANSI/ASTM D2219:2011 Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60 C Operation
  • ANSI/ASTM D4246:2002 Specification for Ozone-Resistant Thermoplastic Elastomer Insulation for Wire and Cable, 90oC Operation
  • ANSI/ASTM A962/A 962M:2001 Specification for Common Requirements, for Steel Fasteners and/or Fastener Materials Intended for Use at Any Temperature from Cryogenic to the Creep Range
  • ANSI/ASTM D4245:2002 Specification for Ozone-Resistant Thermoplastic Elastomer Insulation for Wire and Cable 90oC Dry/75oC Wet Operation

Professional Standard-Ships, nickel working temperature

  • CBM 1022-1981 Allowable temperature and working pressure of marine flange

Danish Standards Foundation, nickel working temperature

  • DS/EN 4049-003:2007 Aerospace series - Thermocouple extension cable - Operating temperatures between - 65 °C to 260 °C - Part 003: Single core nickel chro-mium/nickel aluminium - Product standard
  • DS/EN 4049-004:2007 Aerospace series - Thermocouple extension cable - Operating temperatures between - 65 °C to 260 °C - Part 004: Two core nickel chro-mium/nickel aluminium shielded and jacketed - Product standard
  • DS/ISO 1:1980 Standard reference temperature for industrial length measurements
  • DS/ISO 7243:1994 Ergonomics - Hot environments - Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature)
  • DS/EN 4612-012:2011 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 012: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for op
  • DS/EN 4611-009:2012 Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 °C and 150 °C - Single extruded wall for use as cable cores or within equ
  • DS/EN 6049-008:2013 Aerospace series - Electrical cables, installation - Protective sleeves in meta-aramid fibres - Part 008: Self-wrapping shielded (EMI) protective sleeve with nickel copper braid, flexible post installation operating temperature from - 55 ËšC to 200 ËšC -
  • DS 2323:1986 Ergonomics. hot environments. Estimation of the heat stress on working, man based on the WBGT-index (wet bulb globe temperature)
  • DS/EN 4057-304:2007 Aerospace series - Cable ties for harnesses - Test methods - Part 304: Loop tensile strength at maximum working temperature

Defense Logistics Agency, nickel working temperature

(U.S.) Ford Automotive Standards, nickel working temperature

  • FORD WSK-M1L127-A-2003 CABLE, LOW TENSION, PTFE INSULATED, 260 °C THIN WALL, NICKEL PLATED ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD ESS-M11P24-A1-1983 ADHESIVE, MALE THREADED FASTENER, FOR SERVICE TEMPERATURES BELOW 135 C
  • FORD WSK-M1L127-A2-2003 CABLE, LOW TENSION, PFA INSULATED, 260 °C, THIN WALL, SHIELDED AND TWISTED, NICKEL PLATED, TWO CORE ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD WSA-M2P170-A1-2005 PAINT PERFORMANCE, CORROSION/HEAT RESISTANT COATING, 150 °C, max ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD WSS-M2P178-A-2005 PAINT PERFORMANCE, CORROSION/HEAT RESISTANT COATING, 250 DEGREES C, MAX ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD WSS-M22P6-A6-1997 CABLE, PRIMARY LOW TENSION, 0.15 MM WALL, 200 C (Shown on FORD WSS-M22P6-A1)
  • FORD WSS-M1L137-A-2008 CABLE, PRIMARY LOW TENSION, 150 °C ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD ESS-M11P24-A2-1983 ADHESIVE, MALE THREADED FASTENER, FOR SERVICE TEMPERATURES BELOW 65 C Shown on ESS-M11P24-A1
  • FORD WSS-M2P178-A2-2005 PAINT PERFORMANCE, CORROSION/HEAT RESISTANT COATING, 350 DEGREES C, MAX ***TO BE USED WITH FORD WSS-M99P1111-A*** (Shown on WSS-M2P178-A)
  • FORD WSS-M2C204-A2-2003 FLUID, POWER ASSISTED STEERING, EXTENDED TEMPERATURE RANGE ***TO BE USED WITH FORD WSS-M99P1111-A***
  • FORD WSK-M2G329-A-2007 ADHESIVE, EPOXY, SOLVENT FREE, 180 DEGREES C CURING 80 DEGREES C APPLICABLE, METAL/METAL, STRUCTURAL ***TO BE USED WITH FORD WSS-M99P1111-A***

American Society for Testing and Materials (ASTM), nickel working temperature

  • ASTM B637-12 Standard Specification for Precipitation-Hardening and Cold Worked Nickel Alloy Bars, Forgings, and Forging Stock for Moderate or High Temperature Service
  • ASTM D2219-97 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60176C Operation
  • ASTM D2219-21 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60 ��C Operation
  • ASTM F2004-17 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM F2004-16 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM C667-09 Standard Specification for Prefabricated Reflective Insulation Systems for Equipment and Pipe Operating at Temperatures above Ambient Air
  • ASTM C667-09(2014) Standard Specification for Prefabricated Reflective Insulation Systems for Equipment and Pipe Operating at Temperatures above Ambient Air
  • ASTM B637-12e1 Standard Specification for Precipitation-Hardening and Cold Worked Nickel Alloy Bars, Forgings, and Forging Stock for Moderate or High Temperature Service
  • ASTM A522/A522M-14 Standard Specification for Forged or Rolled 8 and 9% Nickel Alloy Steel Flanges, Fittings, Valves, and Parts for Low-Temperature Service
  • ASTM F2004-05(2010) Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM D2219-02(2007)e1 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60 176;C Operation
  • ASTM D2220-02(2007)e1 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75 176;C Operation
  • ASTM A1048/A1048M-06 Standard Specification for Pressure Vessel Forgings, Alloy Steel, Higher Strength Chromium-Molybdenum-Tungsten for Elevated Temperature Service
  • ASTM D2219-02 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60176;C Operation
  • ASTM D6096-07 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 176;C Operation
  • ASTM D2220-97 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75176C Operation
  • ASTM D2220-02 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75176C Operation
  • ASTM D2220-21 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75 ��C Operation
  • ASTM A1048/A1048M-06(2011) Standard Specification for Pressure Vessel Forgings, Alloy Steel, Higher Strength Chromium-Molybdenum-Tungsten for Elevated Temperature Service
  • ASTM D6096-11(2016) Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90°C Operation
  • ASTM D6176M-97 Standard Practice for Measuring Surface Atmospheric Temperature with Electrical Resistance Temperature Sensors (Metric)
  • ASTM D1523-00(2006) Standard Specification for Synthetic Rubber Insulation for Wire and Cable, 90&176;C Operation
  • ASTM D1523-00 Standard Specification for Synthetic Rubber Insulation for Wire and Cable, 90176;C Operation
  • ASTM D2220-17 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75&xb0;C Operation
  • ASTM D1679-97 Standard Specification for Synthetic Rubber Heat- and Moisture-Resisting Insulation for Wire and Cable, 75176C Operation
  • ASTM D167-93(1999)e1 Standard Test Method for Apparent and True Specific Gravity and Porosity of Lump Coke
  • ASTM D167-93(2004) Standard Test Method for Apparent and True Specific Gravity and Porosity of Lump Coke
  • ASTM F2004-05 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM F2004-00 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM F2004-03 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
  • ASTM D4246-14 Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable, 90°C Operation
  • ASTM D3554-07 Standard Specification for Track-Resistant Black Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 176;C Operation
  • ASTM B637-15 Standard Specification for Precipitation-Hardening and Cold Worked Nickel Alloy Bars, Forgings, and Forging Stock for Moderate or High Temperature Service
  • ASTM E2593-07e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers
  • ASTM E2593-12 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers
  • ASTM D2728-98(2003) Standard Practice for Paving Uses and Application Temperatures for Road Tars
  • ASTM D2728-98 Standard Practice for Paving Uses and Application Temperatures for Road Tars
  • ASTM D2728-98(2014) Standard Practice for Paving Uses and Application Temperatures for Road Tars
  • ASTM E644-98 Standard Test Methods for Testing Industrial Resistance Thermometers
  • ASTM E644-08 Standard Test Methods for Testing Industrial Resistance Thermometers
  • ASTM E644-02 Standard Test Methods for Testing Industrial Resistance Thermometers
  • ASTM E644-11 Standard Test Methods for Testing Industrial Resistance Thermometers
  • ASTM E1137/E1137M-08(2014) Standard Specification for Industrial Platinum Resistance Thermometers
  • ASTM D3554-07(2013) Standard Specification for Track-Resistant Black Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 deg;C Operation
  • ASTM A516/A516M-03 Standard Specification for Pressure Vessel Plates, Carbon Steel, for Moderate- and Lower-Temperature Service
  • ASTM A516/A516M-05 Standard Specification for Pressure Vessel Plates, Carbon Steel, for Moderate- and Lower-Temperature Service
  • ASTM E563-97 Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature
  • ASTM C1146-96 Standard Guide for Prefabricated Panel Insulation Systems for Ducts and Equipment Operating at Temperatures Above Ambient Air
  • ASTM E563-02e1 Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature
  • ASTM E563-02 Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature
  • ASTM E563-11 Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature

RO-ASRO, nickel working temperature

  • STAS 10101/23A-1978 Actions upon structures LOADS DUE TO THE EXTERNAL TEMPERATURE UPON NON-INDUSTRIAL AND INDUSTRIAL STRUCTURES
  • STAS 10101/23-1975 Actions upon structures LOADS DUE TO THE EXTERNAL TEMPERATURE
  • STAS 12449-1986 WORKING CENTERS WITH HORIZONTAL OR VERTICAL SPINDLE Prescriptions for working precision
  • STAS SR ISO 6947:1994 Welds. Working positions. Definitions of angles of slope and rotation.

Society of Automotive Engineers (SAE), nickel working temperature

  • SAE AMS4787F-2000 Gold-Nickel Alloy, Brazing Filler Metal, High Temperature, 82Au 18Ni, 1740°F (949°C) Solidus-Liquidus Temperature
  • SAE AMS2668-1958 SILVER BRAZING Flexible Metal Hose - 400 F Max Operating Temperature
  • SAE AMS2669-1958 SILVER BRAZING Flexible Metal Hose - 800 F Max Operating Temperature
  • SAE AMS2667C-1982 SILVER BRAZING For Flexible Metal Hose, 600°F (315°C) Max Operating Temperature
  • SAE AMS2669A-1968 SILVER BRAZING Flexible Metal Hose, 800 F (427 C) Max Operating Temperature
  • SAE AMS2667B-1972 SILVER BRAZING For Flexible Metal Hose, 600 F (316 C) Max Operating Temperature
  • SAE AMS2667A-1968 SILVER BRAZING For Flexible Metal Hose, 600 F (316 C) Max Operating Temperature
  • SAE AMS2669B-1972 SILVER BRAZING For Flexible Metal Hose, 800 F (427 C) Max Operating Temperature
  • SAE AIR6411-2022 Effects of Extremely Cold Temperature on Landing Gear Operation
  • SAE MA1573-1988 Nut, Self-Locking - Steel, Class 1100 MPa/235°C, MJ Thread Procurement Specification For, Metric FSC 5310
  • SAE AMS2669C-1991 Brazing Silver, for Flexible Metal Hose 800°F (425°C) Max Operating Temperature
  • SAE AMS2668C-1991 Brazing, Silver, For Flexible Metal Hose, 400°F (200°C) Max Operating Temperature
  • SAE AMS2669D-1983 Brazing Silver, for Flexible Metal Hose 800°F (425°C) Max Operating Temperature

SAE - SAE International, nickel working temperature

  • SAE AMS4787G-2017 Gold-Nickel Alloy, Brazing Filler Metal, High Temperature, 82Au 18Ni, 1740°F (949°C) Solidus-Liquidus Temperature
  • SAE AMS2668D-1992 BRAZING SILVER@ FOR FLEXIBLE METAL HOSE 400 DEGREES F (200 DEGREES C) MAX OPERATING TEMPERATURE
  • SAE AMS2668B-1972 SILVER BRAZING For Flexible Metal Hose@ 400 F (204 C) Max Operating Temperature
  • SAE AMS2668A-1968 SILVER BRAZING Flexible Metal Hose@ 400 F (204 C) Max Operating Temperature
  • SAE AMS2668C-1982 SILVER BRAZING For Flexible Metal Hose@ 400?F (204?C) Max Operating Temperature
  • SAE AMS2669D-1992 BRAZING@ SILVER@ FOR FLEXIBLE METAL HOSE 800 DEGREES F (425 DEGREES C) MAX OPERATING TEMPERATURE
  • SAE ARP866B-2012 Standard Values of Atmospheric Absorption as a Function of Temperature and Humidity

Military Standards (MIL-STD), nickel working temperature

AT-ON, nickel working temperature

  • ONORM H 5195-1-2001 Prevention of damage by corrosion and scale formation in closed warm-water-heating systems up to 100 ℃ operating tempertures
  • ONORM M 7550-2002 Heating boilers with operation temperatures up to 100℃-Concepts,requirements, testing,marking

Standard Association of Australia (SAA), nickel working temperature

  • AS 1807.12:2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test - Determination of temperature in work zones

Professional Standard - Aviation, nickel working temperature

  • HB 5638-1987 Hexagonal flattened self-locking nuts (maximum working temperature 230°C)
  • HB 5635-1987 Hexagonal slotted self-locking nuts (maximum working temperature 650°C)
  • HB 5634-1981 Hexagonal flattened self-locking nuts (maximum working temperature 650°C)
  • HB 5639-1981 Hexagon slotted self-locking nuts (maximum working temperature 230°C)
  • HB 5635-1981 Hexagonal slotted self-locking nuts (maximum working temperature 650°C)
  • HB 5638-1981 Hexagonal flattened self-locking nuts (maximum working temperature 230°C)
  • HB 5640-1987 Twelve angle flattened self-locking nuts (maximum working temperature 230°C)
  • HB 5636-1987 Twelve angle flattened self-locking nuts (maximum working temperature 650°C)
  • HB 5641-1987 Twelve angle slotted self-locking nuts (maximum working temperature 230°C)
  • HB 5636-1981 Twelve angle flattened self-locking nuts (maximum working temperature 650°C)
  • HB 5637-1981 Twelve angle slotted self-locking nuts (maximum working temperature 650°C)
  • HB 5641-1981 Twelve angle slotted self-locking nuts (maximum working temperature 230°C)
  • HB 5640-1981 Twelve angle flattened self-locking nuts (maximum working temperature 230°C)
  • HB 5637-1987 Twelve angle slotted self-locking nuts (maximum working temperature 650°C)

Professional Standard - Electron, nickel working temperature

  • SJ/Z 9107.1-1987 Operating conditions for industrial-process measurement and control equipment Part 1: Temperature, humidity and atmospheric pressure

PT-IPQ, nickel working temperature

International Organization for Standardization (ISO), nickel working temperature

  • ISO 8279:1985 Aerospace; Plain hexagon nuts with strength classification 1 100 MPa and maximum operating temperature 235 degrees C
  • ISO/R 458:1965 Plastics — Determination of stiffness in torsion as a function of temperature
  • ISO 9662:1994 Aircraft equipment; environmental and operating conditions for airborne equipment; humidity, temperature and pressure tests
  • ISO 8642:1986 Aerospace; Self-locking nuts with maximum operating temperature greater than 425 degrees C; Test methods
  • ISO 8641:1987 Aerospace; Self-locking nuts with maximum operating temperature greater than 425 degrees C; Procurement specification
  • ISO 1:1975 Standard reference temperature for industrial length measurements
  • ISO/DIS 7481 Aerospace — Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C — Test methods
  • ISO 8641:2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 °C - Procurement specification
  • ISO 8642:2008 Aerospace - Self-locking nuts with maximum operating temperature greater than 425 °C - Test methods
  • ISO 5858:1991 Aerospace; self-locking nuts with maximum operating temperature less than or equal to 425 C; procurement specification
  • ISO 5858:1999 Aerospace - Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C - Procurement specification
  • ISO 7481:2000 Aerospace - Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C - Test methods
  • ISO 7995:1985 Aerospace — Fasteners — Nuts, hexagon, self-locking — Strength classification 1 100 MPa — Maximum operating temperature 235 degrees C
  • ISO 109:1982 Textile machinery; Working widths of weaving machines
  • ISO 18096:2013 Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
  • ISO 7060:1982 Caprolactam for industrial use; Determination of crystallizing point
  • ISO 7481:1984 Aerospace; Fasteners; Self-locking nuts with maximum operating temperature less than or equal to 425 degrees C; Test methods
  • ISO/FDIS 7481:2023 Aerospace — Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C — Test methods
  • ISO 7481:2023 Aerospace — Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C — Test methods
  • ISO 21013-4:2012 Cryogenic vessels - Pilot operated pressure relief devices - Part 4: Pressure-relief accessories for cryogenic service
  • ISO 6947:2019 Welding and allied processes — Welding positions

RU-GOST R, nickel working temperature

  • GOST 1791-2014 Nickel and copper-nickel alloys wire for extension leads for thermoelectric temperature transducers. Specifications
  • GOST 28923-1991 Temperatures regulators operating without outside energy source. General technical requirements and methods of test
  • GOST 33229-2015 Tubes for boiler and heat exchanging equipment. Technical specifications. Part 1. Seamless steel pipes to work under pressure not more than 6,4 MPa and at temperatures not exceeding 400 C
  • GOST 8.130-1974 State system for ensuring the uniformity of measurements. General purpose visual pyrometers with disappearing filament. Verification methods and means
  • GOST R 51337-1999 Safety of machinery. Temperatures of touchable surfaces. Ergonomics data to establish temperature limit values for hot surfaces

CEN - European Committee for Standardization, nickel working temperature

  • EN 14706:2005 Thermal insulation products for building equipment and industrial installations Determination of maximum service temperature
  • EN 2997-001:2006 Aerospace series - Connectors@ electrical@ circular@ coupled by threaded ring@ fire-resistant or non fire-resistant@ operating temperatures -65°C to 175°C continuous@ 200°C continuous@ 260°C peak - Part 001: Technical specification
  • EN 2267-002:2012 Aerospace series - Cables@ electrical@ for general purpose - Operating temperatures between - 55 °C and 260 °C - Part 002: General
  • EN 2267-002:2005 Aerospace series - Cables@ electrical@ for general purpose - Operating temperatures between - 55 degrees Celsius and 260 degrees celsius - Part 002: General

CU-NC, nickel working temperature

  • NC 00-06-1966 Standard reference temperatura for industrial length measurements
  • NC 90-14-22-1984 Metrological Assurance. Workiog Resistance Thermometers from 77 up to 923 K. Classlfication
  • NC 90-14-01-1985 Metrologlcal Assurance. Working Resistcince Thermometers. Verificatlon Methods and Means
  • NC 90-14-08-1984 Metrological Assurance. Working Resistance Thermometers from 73, 15 up to 273, 15 K. Verification Methods and Means
  • NC 90-14-35-1988 Standards System for Metrological Assurance. Metastatic Working-Thermometers. Methods and Means of Verification

CZ-CSN, nickel working temperature

  • CSN 13 9736-1975 Thermometer wells with male thread for working excess pressure 32 MPa (≌ 325 kp/cn2)
  • CSN 13 9737-1975 Thermometer wells with female thread for working excess presuro 32 MPa (≌ 325 kp/cm2)
  • CSN ON 73 5111-1967
  • CSN 69 0010-8.1-1993 Stationary pressure vessels. Technical rules. Pressure vessels with working temperature below 0 degree
  • CSN 42 0283-1979 Regulations for treatment of carbon and alloy formed steels used for pressure equipment working at lower temperatures
  • CSN 13 9714-1975 Flanges for thermometer wells for working excess pressure 32 MPa ( ≌ 325 kp/cm2)
  • CSN 47 0085-1959
  • CSN 47 4412-1974 Agricultural machinery. Working widtli of equipment for crops protectioii
  • CSN ISO 109:1993 Textile machinery. Working widths of weaving machines
  • CSN ISO 7243:1993 Hot environments. Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature)

Underwriters Laboratories (UL), nickel working temperature

  • UL 5703 BULLETIN-2007 OUTLINE OF INVESTIGATION FOR DETERMINATION OF THE MAXIMUM OPERATING TEMPERATURE RATING OF PHOTOVOLTAIC (PV) BACKSHEET MATERIALS
  • UL SUBJECT 5703-2007 OUTLINE OF INVESTIGATION FOR DETERMINATION OF THE MAXIMUM OPERATING TEMPERATURE RATING OF PHOTOVOLTAIC (PV) BACKSHEET MATERIALS Issue Number: 1

CH-SNV, nickel working temperature

Japanese Industrial Standards Committee (JISC), nickel working temperature

  • JIS W 0814:2002 Aircraft equipment -- Environmental and operating conditions for airborne equipment -- Humidity, temperature and pressure tests
  • JIS L 5171:1984 Working widths of cotton spinning machinery
  • JIS A 9504:2004 Man made mineral fibre thermal insulation materials
  • JIS A 9504:2011 Man made mineral fibre thermal insulation materials
  • JIS A 9504:2017 Man made mineral fibre thermal insulation materials
  • JIS Z 3211:2008 Covered electrodes for mild steel, high tensile strength steel and low temperature service steel
  • JIS Z 3312:2009 Solid wires for MAG and MIG welding of mild steel, high strength steel and low temperature service steel
  • JIS B 9062:1985 Methods of needle temperature measurement for industrial sewing machine

SE-SIS, nickel working temperature

  • SIS SS-ISO 1:1979 Standard reference temperature for industrial length measurements
  • SIS SS-ISO 8642:1988 Aerospace — Self-locking nuts with maxi- mum operating temperature greater than 425 °C — Test methods
  • SIS SS-ISO 8641:1989 Aerospace — Self-locking nuts with maxi- mum operating temperature greater than 425° C — Procurement specification
  • SIS SS-ISO 5858:1992 Aerospace — Self-locking nuts with maximum operating temperature less than or equal to 425 °C — Procurement specification
  • SIS SS-ISO 7481:1985 Aerospace - Fasteners - Self-locking nuts with maximum operating tern pera- ture less than or equal to 425 °C - Test methods

TR-TSE, nickel working temperature

  • TS 186-1965 STANDARD REFERENCE TEMPERATURE FOR INDUSTRIAL LENGTH MEASUREMENTS
  • TS 3391-1979 NOMINAL PRESSURES AND MATERIALS IN PIPING SYSTEMS BELATED TO OPERATING PRESSURES AND TEMPERATURES

IT-UNI, nickel working temperature

ESDU - Engineering Sciences Data Unit, nickel working temperature

  • ESDU 84007 A-1991 The treatment of calibrations of total air temperature probes for use in flight-test analysis work.
  • ESDU 80017-1980 Thermophysical properties of heat pipe working fluids: operating range between -60 degrees C and 300 degrees C.

IN-BIS, nickel working temperature

European Committee for Electrotechnical Standardization(CENELEC), nickel working temperature

  • HD 413.1-1980 Operating Conditions for Industrial - Process Measurement and Control Equipment Part 1: Temperature Humidity and Barometric Pressure

API - American Petroleum Institute, nickel working temperature

European Association of Aerospace Industries, nickel working temperature

  • AECMA PREN 2266-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +200 Degrees Celsius Edition P 2 [Refer To: ASD-STAN PREN 2266-002, ASD-STAN PREN 2266-003, ASD-STAN PREN 2266-004, ASD-STAN PREN 2266-005, ASD-
  • AECMA PREN 2265-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +150 Degrees Celsius Edition P 2 [Superseded: ASD-STAN PREN 2265-002, ASD-STAN PREN 2265-003, ASD-STAN PREN 2265-004, ASD-STAN PREN 2265-005, AS
  • AECMA PREN 4611-009-2004 Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 009: BJ - Nickel plated copper Operating temperatures, between - 65 Degrees Celsius and 150 Degrees Celsius Single extruded wall for use as cable c
  • AECMA PREN 3545-001-2006 Aerospace series Connectors, electrical, rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures - 55 癈 to 175 癈 Part 001: Technical specification Edition P 4
  • AECMA PREN 3545-001-2004 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 001 : Technical Specification Edition P 3
  • AECMA PREN 3545-001-2002 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 001 : Technical Specification Edition P 2
  • AECMA PREN 2267-003-1991 Aerospace Series Electrical Cables for General Use Operating Temperatures between -55 and +260 Degrees Celsius Product Standard
  • AECMA PREN 3545-007-2002 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 007 : Cable Clamp Product Standard Edition P 2
  • AECMA PREN 3545-007-2004 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 007 : Cable Clamp Product Standard Edition P 3
  • AECMA PREN 3545-007-1995 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 007 : Cable Clamp Product Standard Edition P 1
  • AECMA PREN 2267-1995 Aerospace Series Electrical Cables for General Purpose Operating Temperatures between -55 Degrees Celsius and +260 Degrees Celsius Edition P 2 [Refer To: ASD-STAN PREN 2267-002, ASD-STAN PREN 2267-006]
  • AECMA PREN 3545-008-2005 Aerospace Series Connectors, electrical, rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures - 55 degrees C to 175 degrees C Part 008: Tools for assembly/removal of coding and attachment system Product st
  • AECMA PREN 3545-003-2004 Aerospace series Connectors, electrical, rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures - 55 Degrees C to 175 Degrees C Part 003 : Connectors with female contacts Product standard Edition P 3
  • AECMA PREN 3545-003-2002 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 003 : Connectors with Female Contacts Product Standard Edition P 2
  • AECMA PREN 3545-003-1995 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 003 : Connectors with Female Contacts Product Standard Edition P 1
  • AECMA PREN 3545-004-2004 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 004 : Connectors with Male Contacts - Product Standard Edition P 3
  • AECMA PREN 3545-004-2002 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 004 : Connectors with Male Contacts Product Standard Edition P 2
  • AECMA PREN 3545-004-1995 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees C to 175 Degrees C Part 004 : Connectors with Male Contacts Product Standard Edition P 1
  • AECMA PREN 3545-002-2006 Aerospace series Connectors, electrical, rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures - 55 癈 to 175 癈 Part 002: Specification of performance and contact arrangements Edition P 5
  • AECMA PREN 3545-002-1998 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Device, Operating Temperatures - 55 Degrees Celsius to 175 Degrees Celsius Part 002: Specification of Performance and Contact Arrangements Edi
  • AECMA PREN 3545-002-2004 Aerospace series Connectors, electrical rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures -55 Degrees Celsius to 175 Degrees Celsius Part 002: Specification of performance and contact arrangements Editi
  • AECMA PREN 3545-002-1995 Aerospace Series Connectors, Electrical, Rectangular, with Sealed and Non-Sealed Rear, Plastic Housing, Locking Devices, Operating Temperatures - 55 Degrees Celsius to 175 Degrees Celsius Part 002: Specification of Performance and Contact Arrangements Ed
  • AECMA PREN 2266-002-2000 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures between - 55 Degrees C and 200 Degrees C Part 002: General Edition P 2
  • AECMA PREN 2266-002-1995 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures between - 55 Degrees C and 200 Degrees C Part 002: General Edition P 1
  • AECMA PREN 2265-002-1995 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures Between -55 Degrees Celsius and +150 Degrees Celsius Part 002: General Edition P 1 [Superseded By: ASD-STAN PREN 2265]
  • AECMA PREN 2267-002-1995 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures between - 55 Degrees C and 260 Degrees C Part 002: General Edition P 1
  • AECMA PREN 2267-002-2000 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures between - 55 Degrees C and 260 Degrees C Part 002: General Edition P 2
  • AECMA PREN 2267-002-2003 Aerospace Series Cables, Electrical, for General Purpose Operating Temperatures between -55 Degrees C and 260 Degrees C Part 002: General Edition P 3

HU-MSZT, nickel working temperature

Professional Standard - Aerospace, nickel working temperature

  • QJ 1753-1989 Test method for self-locking nuts with MJ threaded fasteners with a maximum operating temperature greater than 425°C
  • QJ 1756-1989 Technical conditions for self-locking nuts with MJ threaded fasteners with a maximum working temperature greater than 425°C
  • QJ 1752-1989 Test method for self-locking nuts with MJ threaded fasteners whose maximum working temperature is less than or equal to 425°C
  • QJ 1755-1989 Technical conditions for self-locking nuts with MJ threaded fasteners whose maximum working temperature is less than or equal to 425°C

American Society of Mechanical Engineers (ASME), nickel working temperature

  • ASME SEC III D1 NMA APP R-2001 Appendix R Determination of Permissible Lowest Service Metal Temperature from Tndt for Classes 2 and MC Construction
  • ASME 2333-2001 Minimum Design Temperature for Tubes Absorbing Heat Section I ANNULLED

国家市场监督管理总局、中国国家标准化管理委员会, nickel working temperature

  • GB/T 37052-2018 Test methods for nominal module operating temperature of building integrated photovoltaic(BIPV) modules

AENOR, nickel working temperature

  • UNE 28581:1986 AEROSPACE. FASTENERS. SELF-LOCKING NUTS WITH MAXIMUM OPERATING TEMPERTURE LESS THAN OR EQUAL TO 425oC. TEST METHODS.
  • UNE 40020:1957 USEFUL WIDTH OF WORK FOR COTTON CARDS.

GOSTR, nickel working temperature

  • GOST R 58400.1-2019 Automobile roads of general use. Petroleum-based bitumen binder. Specifications based on operational temperature range

BR-ABNT, nickel working temperature

NEMA - National Electrical Manufacturers Association, nickel working temperature

ES-AENOR, nickel working temperature

BE-NBN, nickel working temperature

Inner Mongolia Provincial Standard of the People's Republic of China, nickel working temperature

  • DB15/T 1463-2018 Determination of nickel content in sodium hydroxide for industrial use spectrophotometric method

International Electrotechnical Commission (IEC), nickel working temperature

  • IEC 60246:1967 Connecting wires having a rated voltage of 20 kV and 25 kV d.c. and a maximum working temperature of 105 °C for use in television receivers
  • IEC TS 62492-1:2008 Industrial process control devices - Radiation thermometers - Part 1: Technical data for radiation thermometers

General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China, nickel working temperature

  • GB/T 18153-2000 Safety of machinery-Temperatures of touchable surfaces-Ergonomics data to establish temperature limit values for hot surfaces

ITE - Institute of Transportation Engineers, nickel working temperature

  • LP-409-2000 Procedure for Determining Work Zone Speed Limits

CO-ICONTEC, nickel working temperature





Copyright ©2007-2023 ANTPEDIA, All Rights Reserved